Have a look at the manual Honeywell Sundial RF Pack 4 Wireless Enabled Timer and Cylinder Thermostat User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21 FAQ AND TROUBLESHOOTING How do I set the time only, if the ST9120C clock is not correct? Your ST9120C contains an accurate digital clock that is factory set. Should you ever need to change the time, just follow this procedure: a. Move the slider to the DAY/TIME position. b. Keep pressing the green button until the message ‘SET THE TIME’ is displayed. To change the time, press the or buttons until the correct time is shown. The message ‘IS TIME OK?’ will be displayed. Press the green button to confirm the time is correct. If you have made a change, the message ‘TIME SAVED’ will show, followed quickly by ‘DATE + TIME COMPLETE’. c. Move the slider to the RUN position, to complete changing the time. What do I do when the clocks go back in October and forward in March? Your ST9120C is factory set to change the clock automatically at the correct dates, so you should never need to adjust the clock forward or backwards yourself. It is possible to disable this particular feature, as described in the section ‘Changing the Installer Parameters’ (page 15). You may also check the section ‘Configuration & Service Data’ (page 26) to see how your Installer has configured your product. What should I do if I get ‘lost’ while programming the ST9120C? The LoT™ Display on ST9120C will provide you with help and tips to work through the programming. Should you ever get ‘lost’, the simplest thing to do is\ to move the slider to the RUN position, and then move it back to the appropriate programming position where you got lost. At this point just follow the instructions again. What happens if there is a power failure? In the event of a mains power failure, the ST9120C display will go blank, the indicator lamps will go out, and the control outputs will switch off. The real time will be constantly maintained by means of the built-in battery backup, ready to power back up as if nothing had happened when the mains power is restored. In addition, all programmes and settings are stored in a special memory (called Non Volatile memory) which requires no power to maintain information so will be retained indefinitely. Should the correct time and date ever be lost, for whatever reason, the message ‘SET DATE + TIME’ will be displayed whilst the slider is in the RUN position. In this case, simply follow the procedure described under ‘Step 1: Setting the Date & Time’ (page 6). It should not be necessary to make any changes to your programmes.
22 FAQ AND TROUBLESHOOTING How reliable is 2-way RF communication? The 2-way RF communication (also known as wireless communication) used by Honeywell is extremely robust and reliable. When installed correctly the Signal Strength test feature allows the Installer to locate the system components where mutual signal reception is strong. During communication, signals are sent several times to ensure receipt, and if any message is garbled, the error detection software recognises this and ensures the message is repeated again. What do I do if RF communication is lost? Follow the steps in the Troubleshooting Guide on the next page. The most likely cause for loss of communications is the CS92A batteries running low on p\ ower. This will be indicated on CS92A, as described on page 19. Simply replace the batteries (as shown on page 19) and wait a few minutes for communications to bec\ ome re- established. If this does not resolve the problem it may be that the RF signal path between the ST9120C and the CS92A is blocked by a metal object. Check the direct path between the two devices and reposition any object that may be blocking the signal, or move the thermostat. How do I know when to change the batteries in the CS92A cylinder thermostat? If the CS92A batteries need changing, ST9120C will show the message ‘\ SENSOR LOW BATT’ and the tap symbol will flash. . You can confirm this by pressing the CS92A button, whereupon the red light will give a brief flash every second to indicate a low batter y state. It is important to change the CS92A batteries as soon as the low battery condition is indicated, as reduced battery power may affect the RF signal strength and impair RF communications.
23 FAQ AND TROUBLESHOOTING Troubleshooting Guide This is a quick guide to help you diagnose and cope with possible problems with your wireless control system. For further assistance, please contact your Installer. SymptomPossible CauseRemedy ST9120C has a blank LCD display No power to the heating systemCheck that there is power to the heating system Fault in ST9120C Call Installer ST9120C indicates the system is ON, but taps are running with cold water. Temperature controls are switched off or set too lowCheck that the temperature controls in the system are set to appropriate levels Boiler or other system controls have malfunctioned Call Installer ST9120C shows the message: ‘INTERNAL FAULT’ Fault in ST9120C Call Installer Every few seconds, the ST9120C screen shows the message: ST9120C is counting down the number of days until your next boiler service is due.Arrange a boiler service before the counter reaches zero. After servicing your boiler, the Service Engineer / Installer will reset the ST9120C to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart. Although the heating is still operating, the ST9120C screen keeps flashing the message:Your boiler service is overdue. Arrange an immediate boiler service. After servicing your boiler, the Service Engineer / Installer will reset the ST9120C to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart. The ST9120C screen shows the message: Your boiler service is overdue and the boiler has been automatically switched off to ensure your safety.Arrange an immediate boiler service. If set to do so, it may be possible to obtain limited use of the boiler by pressing the EXTRA HOUR button. Each button press will allow operation of the boiler for 1 hour at a time, and the screen will display the message ‘On 1h’. After servicing your boiler, the Service Engineer / Installer will reset the ST9120C to remind you when the next boiler service is due. Each service is normally a maximum of 1 year apart.
24 SymptomPossible CauseRemedy ST9120C shows the message ‘SENSOR LOW BATT’ and a flashing tap symbol CS92A batteries are running low on power Change the CS92A batteries (see page 19 for how to do this) CS92A battery low indication (press CS92A button and red light gives a short flash every second 0.1s on, 0.9s off. Note: light will switch off after approx 1 minute to save battery power) ST9120C shows the message ‘NO SIGNAL’ and a flashing tap symbolCS92A batteries are running low on powerChange the CS92A batteries (see page 19 for how to do this) RF communication path between ST9120C and CS92A is blocked, possibly by a metal object Check direct path between both products and re-position any objects that may be blocking the signal Relocate the CS92A transceiver, if possible ST9120C shows the message ‘SENSOR FAULT’ and a flashing tap symbol CS92A sensor error indication (Press CS92A button and red light blinks 0.5s on, 0.5s off. Note - light will switch off after approx 1 minute to save battery power CS92A sensor cable may be disconnected from the wiring terminals Re-connect the sensor wires to the CS92A terminals Fault with CS92A Call Installer Troubleshooting Guide (cont.) FAQ AND TROUBLESHOOTING
2650047645-002 A CONFIGURATION & SERVICE DATA Configuration Data (to be completed by Installer) The tables below are for the Installer to complete to indicate how your ST9120C has been configured. Application Insert application number as per Installation wiring diagrams: Configurable FeaturesOptionsFactory settingInstaller configured (tick box or note value) ST9120C Configuration - standard 24hr or am/pm clock display. am/pm display 24hr display Display backlight operation. Off on if button pressed on continuously Automatic time change.disabled, enabled 1-day or 5/2-day or 7-day operation.1-day operation 5/2-day operation 7-day operation Number of ON/OFFs per day.2 on/offs per day, 3 on/offs per day Default time programme. A = standardb = at home C = economy Hot water set temperature From 40 to 85°C60°C Optimum start no optimum start delayed start optimum start on Optimum start limit 1 hour 2 hours 3 hours Optimum stop disabled enabled Frost protection temperature From 5 to 16°C5°C Minimum ON/OFF time 1, 2, 3, 4, 5 minutes1 minute Cycle rate 3, 6, 9, 12 cycles per hour6 cycles Proportional band width From 1.5 to 3.0°C1.5°C Failsafe mode (loss of RF communications) off on 20% * * This option will not operate on a hot water only system