Page 11

11
PROGRAMMING YOUR  ST9120C
Exiting Programming Mode:
To exit programming mode, move the slider to the RUN position. This can be done at 
any time during the programming process, and any changes made and confirmed 
with the 
 button will have been saved.
Note: If the unit is left in Programming mode for more than 10 minutes without the slider 
being moved or any buttons pressed, the message ‘MOVE SLIDER’ will be displayed.  
Press a button to finish programming, or move the slider to the RUN  position....

Page 12

12
OPERATING YOUR  ST9120C
Choosing the Operating Mode
The operating mode may only be changed when the slider is set to the RUN position.
The   symbol is displayed during a programmed on period. A green INDICATOR 
LAMP shows when the system is switched ON.
A  MODE button is provided to select the Operating Mode and therefore how the 
system is controlled.
There are four possible Operating Modes; these are OFF,  AUTO, ONCE,  CONT.  
Pressing the MODE button scrolls round these modes in sequence, and the...

Page 13

13
OPERATING YOUR  ST9120C
The Extra Hour Function
The EXTRA HOUR button allows you to switch the system ON for up to 3 extra hours 
without altering the programme. Pressing the button once will give one extra hour.  
The  LoT™ Display will display the message ‘+ 1 HOUR’, to confirm the button has 
been pressed. 
When the system is OFF (the  symbol is not displayed), pressing the EXTRA 
HOUR button switches the system ON for just one hour.
When the system is
  ON (the  symbol is displayed), pressing the...

Page 14

14
OPERATING YOUR  ST9120C
Enquiry Mode
As the heart of your system, the ST9120C has access to temperature information 
from the other system components, and allows you to enquire about this information.
To enter Enquiry Mode, ensure the slider is in the RUN position, then press and 
hold the 
 button for 4 seconds.
The  LoT™ Display will show the message ‘INFO MENU’ to confirm that you have 
entered Enquiry Mode.
Pressing the 
  or  buttons then allows you to step around and view the available...

Page 15

15
FINE TUNING YOUR  ST9120C
Changing from AM/PM Time Display to the 24 Hour Clock
Your ST9120C can operate on the 12 hour AM/PM or 24 hour clock formats. To 
change the format, ensure the slider is in the RUN position then press and hold the 
  and  buttons together for about 2 seconds. Ignore the ‘NOT VALID’ message 
that will appear briefly. Then the displayed times will be changed automatically to 
the new format.
Repeating this procedure will change the clock display back to the original format....

Page 16

16
To Enter Installer Mode:
a. Ensure the slider is in the RUN  position, then press and hold 
 and  buttons 
together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a 
few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET 
INSTALLER OK ?’
b.  Press the 
 button to take you into the Installer Mode Parameter Menu.
c.  Parameter 1 is now available to change. This is to allow you to change t\
he 
clock format from 12 hour AM/PM to 24 hour. At every step, the LoT™...

Page 17

17
FINE TUNING YOUR  ST9120C
e. Press  to move to the next parameter available for editing.
f.   Keep pressing 
 to step around the list of parameters, and use   or  
buttons to change the parameter value.
g.  Any parameter changes that have been confirmed with the 
 button will be 
saved and used.
To Exit Installer Mode:
h.  You can exit Installer Mode at any time by moving the slider to the next \
position 
and then back again to RUN .
  Note: Installer Mode will exit automatically after 10 minutes if...

Page 18

18
BOILER SERVICE REMINDER
If your house is rented, by Law, your gas boiler should be inspected once a year to 
ensure it is operating safely. Your ST9120C Timer has a range of features designed 
to help make sure this service is carried out at the correct time. These features will be 
programmed by your Installer, Maintenance Engineer, or Landlord.
•	 If	it	has	 been	 set	to	do	 so,	 ST9120C	 will	display	 a	message	 on	the	 screen	 to	
remind you that a boiler service is due.
•	 If	 the	service	 is...

Page 19

19
Shut-down
If your ST9120C shows the words “SERVICE 
DUE” and “OFF” then your boiler service is 
overdue and the boiler has been automatically 
switched off to ensure your safety – you should 
arrange an immediate service visit.
If set to do so, it may be possible to obtain limited 
use of the boiler by pressing the EXTRA HOUR 
button. Each button press will allow operation of 
the boiler for 1 hour at a time, and the screen will 
display the message “On 1h” as shown. However, 
you should still arrange...

Page 20

20
Error Indications
To save battery power, CS92A will indicate 
error conditions on the LoT™ Display of 
ST9120C. It is possible to view the CS92A sta-
tus by pressing the button on the transceiver 
box. The lights underneath this button will 
provide feedback as shown in the table. Go 
to the FAQ AND TROUBLSHOOTING section 
for more information.
Green LightRed Light Status
On Flashes up to 5 times in 
succession, then repeats
Everything is OK, red light shows signal 
strength - press button again to...