    Have a look at the manual Honeywell Sundial RF Pack 1 Wireless Enabled Timer and Thermostat User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    PROGRAMMING YOUR  ST9120C
    Exiting Programming Mode:
    To exit programming mode, move the slider to the RUN position. This can be done at 
    any time during the programming process, and any changes made and confirmed 
    with the 
     button will have been saved.
    Note: If the unit is left in Programming mode for more than 10 minutes without the 
    slider being moved or any buttons pressed, the message ‘MOVE SLIDER’ will be 
    displayed.  Press a button to continue programming, or move the slider to the  RUN 
    position.
    Disabling / Enabling Time Periods
    To disable any of the time periods ON 1 to OFF 1,  ON 2 to OFF 2, or ON 3 to OFF 3, 
    simply set the ON time and its paired OFF time to the same time, and the programme 
    will just ignore them. 
    To re-enable the time period, simply set the two ON and OFF times to be different. 
    						
    							12
    OPERATING YOUR  ST9120C
    Choosing the Operating Mode
    The operating mode may only be changed when the slider is set to the RUN position.
    The  symbol is displayed during a programmed heating on period. A green 
    INDICATOR LAMP shows when the heating is switched ON.
    A  MODE button is provided to select the Operating Mode and therefore how the 
    heating is controlled.
    There are four possible Operating Modes; these are OFF,  AUTO, ONCE,  CONT.  
    Pressing the MODE button scrolls round these modes in sequence, and the display 
    indicates which mode is currently active.
    •	 OFF mode
      The system will remain OFF.
    •	 AUTO (Automatic) mode
      The system will be switched ON and OFF according to the programme.
    •	 ONCE mode
      The system will come ON at the first programmed ON time, and go OFF at the 
    last programmed OFF time.
    •	 CONT (Continuous) mode
      The system will remain ON continuously.
    Overriding the Operation Without Changing the Programmes
    In AUTO  and ONCE operating modes, the OVERRIDE button switches the heating 
    ON or OFF without altering the programme. 
    When the 
     symbol is displayed, pressing the OVERRIDE button switches the 
    heating OFF until the next programmed ON time.
    If the 
     symbol is not displayed, pressing the OVERRIDE button switches the 
    heating ON until the next programmed OFF time.
    The LoT™ Display will provide you with information about the override. 
    						
    							13
    OPERATING YOUR  ST9120C
    The Extra Hour Function
    The EXTRA HOUR button allows you to switch the system ON for up to 3 extra hours 
    without altering the programme. Pressing the button once will give one extra hour.  
    The  LoT™ Display will display the message ‘+ 1 HOUR’, to confirm the button has 
    been pressed. 
    When the heating is OFF (the  symbol is not displayed), pressing the EXTRA 
    HOUR button switches the heating ON for just one hour.
    When the heating is
      ON (the  symbol is displayed), pressing the  EXTRA HOUR 
    button extends the programmed ON period by one hour.
    Further presses of the EXTRA HOUR button will increase the extra hour period by 
    one hour for each button press, up to a maximum of 3 hours.  The LoT™ Display will 
    continue to provide information on the extra hour status.
    To cancel the extra hours, just keep pressing the EXTRA HOUR button until the 
    ‘CANCELLED’ message appears on the LoT™ Display.
    The Holiday Function
    The Holiday function allows you to switch off your system for a specified number of 
    days (from 1-99 days).  This lets you save energy and related costs when you are 
    away from home, but resumes normal operation on the day of your return.
    During this period heating will operate at the OFF (frost protection) set temperature.
    To set the Holiday function:
    a.  Ensure the slider is in the  RUN position, then press the HOLIDAY button once. 
    The message ‘SET HOLIDAY’ will appear briefly, followed by ‘SET DAYS AWAY’.
    b. 
    Use the   or  buttons to set the number of days you will be away. The display 
    will show the number of days, and this number will be flashing to indi\
    cate it can be 
    changed. The day of the week will also keep changing to show the day you\
     return.
    c. If you have made a change to the number of days, the message ‘DAYS AWAY OK ?’ 
    will appear. Press the green  button to confirm your selection.
    d. 
    The message ‘SAVED’ will be displayed for a few seconds, followed by the date you 
    return, to enable you to check you have programmed the holiday function correctly.
    e.  During the holiday period, the LoT™ Display will show the message ‘ON 
    HOLIDAY’ and the display will count down the number of days till you return.
    To cancel the Holiday function:
    f.   To cancel the Holiday function, just press the HOLIDAY button again. The LoT™ 
    Display will show ‘CANCELLED’ and the unit will return to normal operation.
    Note: while setting the Holiday function, if there is a gap of more than 1 minute 
    between button presses, the function will cancel itself automatically and return to 
    normal operation. 
    						
    							14
    OPERATING YOUR  ST9120C
    Enquiry Mode
    As the heart of your system, the ST9120C has access to temperature information 
    from the other system components, and allows you to enquire about this information.
    To enter Enquiry Mode, ensure the slider is in the RUN position, then press and 
    hold the 
     button for 4 seconds.
    The  LoT™ Display will show the message ‘INFO MENU’ to confirm that you have 
    entered Enquiry Mode.
    Pressing the 
      or  buttons then allows you to step around and view the available 
    information. The LoT™ Display will continue to update to tell you what inf\
    ormation 
    is being viewed, and the main display will show the value. If the information is not 
    available, the display will show dashes -- -- instead of a temperature value. The table 
    below shows the type and sequence of information available in Enquiry Mode.
    To exit Enquiry Mode:
    If the  button is not pressed for 30 seconds, your ST9120C will return to RUN  mode.
    InformationLoT™ MessageOther display symbols
    * Room temperature ROOM TEMP
    * Room temperature settingROOM SET
    Ŧ Hot water temperatureWATER TEMP
    Ŧ Hot water temperature settingWATER SET
    * This information will be available if you have a room temperature control system, with a DT92E 
    room thermostat.
    Ŧ 
    This information will be available if you have a hot water control system, with a CS92A hot water sensor
    /
    /
    // 
    						
    							15
    FINE TUNING YOUR  ST9120C
    Changing from AM/PM Time Display to the 24 Hour Clock
    Your ST9120C can operate on the 12 hour AM/PM or 24 hour clock formats. To 
    change the format, ensure the slider is in the RUN position then press and hold the 
      and  buttons together for about 2 seconds. Ignore the ‘NOT VALID’ message 
    that will appear briefly. Then the displayed times will be changed automatically to 
    the new format.
    Repeating this procedure will change the clock display back to the original format.
    Changing the Installer Parameters
    The ST9120C has a special Installer Mode where some features can be adjusted 
    to suit your lifestyle or preferences – these are called Installer Parameters, and are 
    listed in the table below, along with a description of the options that are possible.
    Your installer should set this up for you to suit your application (see \
    CONFIGURATION 
    & SERVICE DATA section). However, you may wish to alter some of the settings 
    yourself, and this section shows you how to do this.
    Note: some parameters indicated by * may only be viewed if the previous parameter 
    is set to a particular value.
    # Set hot water temperature is only used when the system contains a CS92A wireless 
    hot water sensor, and is not used in this system.
    INSTALLER 
    PARAMETER Parameter 
    Number Default 
    Value Options
    Description
    24hr or am/pm 
    clock display. 1
    1212, 24 12 = am/pm display
    24 = 24hr display
    Configure backlight 
    operation.2 20, 1, 2 0 = off 
    1 = on if button pressed
    2 = on continuously
    Enable/disable auto 
    time change. 3
    10, 10 = disabled
    1 = enabled
    1-day or 5/2-day or 
    7-day operation.4 71, 5, 7 1 = 1-day operation
    5 = 5/2-day operation
    7 = 7-day operation
    Number of ON/OFFs 
    per day.5 32, 32 = 2 on/offs per day
    3 = 3 on/offs per day
    Select default time 
    programme. 6
    AA, b, C A = standard
    b = at home
    C = economy
    # Set hot water 
    temperature8 60°C 40 to 
    85°CStored hot water set 
    temperature 
    						
    							16
    To Enter Installer Mode:
    a. Ensure the slider is in the RUN  position, then press and hold 
     and  buttons 
    together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a 
    few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET 
    INSTALLER OK ?’
    b.  Press the 
     button to take you into the Installer Mode Parameter Menu.
    c.  Parameter 1 is now available to change. This is to allow you to change t\
    he 
    clock format from 12 hour AM/PM to 24 hour. At every step, the LoT™ Display 
    will inform you what the parameter means and what option you have selected. 
    The parameter number is shown on the display separated by a colon from the 
    parameter value.
    d.  You can change the parameter value by pressing the 
      or  buttons. At this 
    point the description in the LoT™ Display will change and the parameter value 
    will flash. If you press 
     the value will stop flashing and be saved for use.
    INSTALLER 
    PARAMETER Parameter 
    Number Default 
    Value Options
    Description
    Optimum start9 00, 1, 2 0 = no optimum start1 = delayed start
    2 = optimum start on
    * Optimum start limit 1011, 2, 3 1 = 1 hour
    2 = 2 hours
    3 = 3 hours
    Optimum stop11 00, 10 = disabled
    1 = enabled
    Frost protection 
    temperature 12
    55 to 
    16°C Frost protection 
    temperature
    Minimum ON/OFF 
    time 13
    11, 2, 
    3, 4, 5  mins Minimum ON/OFF time 
    in minutes
    Cycle rate14
    63, 6, 9, 
    12 Number of boiler cycles 
    per hour 
    Proportional band 
    width 15
    1.51.5 to 
    3.0°C  Width of control 
    proportional band in °C 
    Failsafe mode (loss of 
    RF communications)16
    00, 10 = off
    1 = heating on  20%
    Reset all parameters20 10, 10 = do not reset
    1 = default parameters
    FINE TUNING YOUR  ST9120C 
    						
    							17
    FINE TUNING YOUR  ST9120C
    e. Press  to move to the next parameter available for editing.
    f.   Keep pressing 
     to step around the list of parameters, and use   or  
    buttons to change the parameter value.
    g.  Any parameter changes that have been confirmed with the 
     button will be 
    saved and used.
    To Exit Installer Mode:
    h.  You can exit Installer Mode at any time by moving the slider to the next \
    position 
    and then back again to RUN .
      Note: Installer Mode will exit automatically after 10 minutes if the slider is not 
    moved.
    Optimisation
    The Optimisation features are explained on page 5. Parameters 9, 10, and 11 are 
    used to enable or disable and set these features to suit your requirements. You can 
    set Optimum Start, Delayed Start, or Optimum Stop, and you can also set a limit to 
    the Optimum Start time of 1, 2, or 3 hours.
    Note: the radiator symbol 
     will flash to indicate Optimisation is taking place.
    The diagrams below illustrate how Optimisation works.
    0500 0600 0700 Time
    Comfort
    temperature Optimum Start
    Optimum StartProgrammed Time
    Temperature
    ON
    OFF
    0500 0600 0700 Time
    Comfort
    temperature Programmed Time
    Delayed StartDelayed Start
    Temperature
    ON
    OFF
    2100 2200 2300 Time
    Optimum Stop
    Optimum StopProgrammed Time
    Temperature
    ON
    OFF 
    						
    							18
    BOILER SERVICE REMINDER
    If your house is rented, by Law, your gas boiler should be inspected once a year to 
    ensure it is operating safely. Your ST9120C Timer has a range of features designed 
    to help make sure this service is carried out at the correct time. These features will be 
    programmed by your Installer, Maintenance Engineer, or Landlord.
    •	 If	it	has	 been	 set	to	do	 so,	 ST9120C	 will	display	 a	message	 on	the	 screen	 to	
    remind you that a boiler service is due.
    •	 If	 the	service	 is	overdue,	 the	Timer	 may	switch	 off	the	 heating	 system,	 to	ensure	
    your safety. If this happens you must arrange an immediate service visit. Contact 
    details should be listed on page 31 of this guide, in the section Boiler\
     & System 
    Service Log.
    •	 A	 contact	 telephone	 number	may	also	have	 been	 programmed	 into	the	ST9120C.	
    If so, a message will appear on the LoT™ Display indicating the number you 
    should call.
    Countdown to Service
    Your ST9120C can indicate a countdown for the 
    number of days until your service is due. This 
    message will appear on the screen every few 
    seconds, to give you an opportunity to schedule 
    a service visit.
    When Service is Due
    When your boiler service is OVERDUE the words 
    “SERVICE DUE” will continue to flash on your 
    screen, and you should arrange an immediate 
    service visit. 
    						
    							19
    Shut-down
    If your ST9120C shows the words “SERVICE 
    DUE” and “OFF” then your boiler service is 
    overdue and the boiler has been automatically 
    switched off to ensure your safety – you should 
    arrange an immediate service visit.
    If set to do so, it may be possible to obtain limited 
    use of the boiler by pressing the EXTRA HOUR 
    button. Each button press will allow operation of 
    the boiler for 1 hour at a time, and the screen will 
    display the message “On 1h” as shown. However, 
    you should still arrange an immediate service visit, 
    as this will allow you to comply with the law and 
    ensure your gas boiler is operating safely.
    BOILER SERVICE REMINDER
    OPERATING YOUR  DT92E
    Inquiring about the Set Temperature
    DT92E normally displays the 
    measured room temperature.
    To inquire about the set 
    temperature, simply press 
    one of the 
     or  buttons. 
    The set temperature will be 
    shown on the display along 
    with the arrow symbols, 
    and the temperature will be 
    flashing.
    Adjusting the Set Temperature
    The set temperature is 
    adjusted by pressing the  
    or  buttons. Each time one 
    of the buttons is pressed, the 
    set temperature will change 
    by 0.5°C.
    =°C
    =°C 
    						
    							20
    OPERATING YOUR  DT92E
    Switching Off
    Pressing the off/standby button  for 2 seconds will switch the 
    DT92E into off/standby mode. 
    The 
     symbol will show in the 
    display, and the unit will control 
    at the frost protect setpoint, as 
    set at the ST9120C.
    To switch back on, simply press 
    the 
     button for 2 seconds again. 
     
    Display Updates
    To conserve battery power, DT92E only communi-
    cates with ST9120C at regular intervals or when you 
    press a button. This means there can be up to a 
    few minutes delay between an action initiated on 
    ST9120C and the DT92E display being updated.
    If you press a button on DT92E it may take a few 
    seconds for ST9120C to respond. DT92E will 
    indicate it is waiting for information by displaying the 
    hourglass symbol and dashes as shown.
    Heating Indicator
    The flame symbol indicates that the 
    boiler is on for heating. The flame will 
    disappear when there is no heating 
    demand.
    Frost Protection
    The frost symbol will be displayed if the room 
    temperature goes below the frost setting. The flame 
    will also be displayed to indicate when the boiler has 
    been switched on.
    2 s
    2 s 
    						