Page 61

Symphony/Symphony-i Setup (Contd) 
61 
 
How to Adjust the Volume  
You may adjust the Symphony/Symphony-i speaker volume by pressing your finger 
on the touch screen slide bar associated with the Volume scale and doing the 
following: 
If… Then… 
you want to increase volume  move the slide bar above the current volume setting. 
you want to decrease volume  move the slide bar below the current volume setting. 
AUI-019-V1
VOLUME
SLIDEBAR
INDICATOR
 
Symphony/Symphony-i Volume Control 
How to Select Screen...

Page 62

Symphony/Symphony-i Setup (contd) 
62 
 SCREEN ACTION 
 2.  Select the time period option you want by 
pressing it.  The pop-up window closes 
automatically and the selection is displayed in 
blue. 
NOTE:  Additional options can be viewed by 
using the up/down arrows to scroll through 
the time period options. 
 
 
 3.  Press either the Home or Back icon.  A 
Keypad Profile pop-up window is displayed 
stating “Saving Profile.. Please Wait  W hen 
the Profile update is complete, 
Symphony/Symphony-i goes...

Page 63

Symphony/Symphony-i Setup (Contd) 
63 
 
How to Set the Time and Date 
You can set the time and date from the Set Time & Date screen. This screen can 
be accessed by pressing the Time and Date bar located at the bottom of each 
Symphony/Symphony-i screen.    
• Since Synchronized with network clock is always selected on the Set Time 
& Date screen, whenever Symphony/Symphony-i checks in with the server 
(every 10 seconds) it will get the current GMT time.  If the 
Symphony/Symphony-i time differs from...

Page 64

Symphony/Symphony-i Setup (contd) 
64 
 
Time Zones 
Using the chart below, select the time zone number corresponding to the location of 
the installation
. 
Time Zone Settings 
Z
A
B
C
D
F
G
H
I
N
O
P
Q
R
S
T
U
W
E
STANDARD TIME ZONES
Corrected to June 2000Zone boundaries are approximate
Daylight Saving Time (Summer Time),
usually one hour in advance of Standard
Time, is kept in some places
Map outline © Mountain High Maps
Compiled by HM Nautical Almanac Office
Z
A
B
C
C*
D
D*
E   0
+ 1
+ 2
+ 3
+ 3 30
+...

Page 65

Symphony/Symphony-i Setup (Contd) 
65 
 
How to Calibrate the Touch Screen 
Calibrate the touch screen as follows:  
SCREEN ACTION 
 1.  From the Home screen, press the “Tool 
Box” button.  The Setup screen is displayed. 
 4.  Press the Advanced Setup button on the 
Setup screen.  The User Authorization 
screen is displayed with the instructions Enter 
Authorized Code. 
 
 5.  Enter your “Master” code.  The “Advanced 
Setup” screen is displayed. 
 
 6.  Press the Diagnostics button on the 
Advanced Setup...

Page 66

Symphony/Symphony-i Setup (contd) 
66 
 SCREEN ACTION 
 7. Begin the Touchscreen calibration from the 
Diagnostics screen by pressing the 
Calibrate button. W hen the Calibrate button is 
pressed, the Touch Screen Calibration 
screen is displayed. 
 
 
 
 8.  W ithin the Touch Screen Calibration 
screen you are asked to Press the center of 
the box in upper left corner. Press the center 
of the square. 
W hen this square is touched, the Touch 
Screen Calibration screen displays Next 
press the box in the...

Page 67

Symphony/Symphony-i Setup (Contd) 
67 
 SCREEN ACTION 
 10. Press the center of the square. The Touch 
Screen Calibration screen displays Next 
press the box in lower left corner. 
 
 
 
 11.  Press the center of the square. The 
Touch Screen Calibration screen displays 
Touch target to verify calibration.  
If touch screen calibration was not successful, 
Calibration Unsuccessful is displayed 
momentarily. You are then returned 
automatically to the first Touch Screen 
Calibration screen. 
NOTE: You...

Page 68

Symphony/Symphony-i Setup (contd) 
68 
  

Page 69

Maintaining Your System 
69 
 
Replacing Batteries In Wireless Sensors 
 
 
 Wireless sensors may not have been used in your security system. 
If your system has wireless sensors, each wireless sensor in your system has a 9-
volt or 3-volt battery. The system detects a low battery in any wireless sensor, 
including smoke detectors, the optional personal emergency transmitter, and the 
optional portable wireless Keypad. (A low battery in a portable wireless Keypad is 
detected as soon as one of its keys...

Page 70

Maintaining Your System (contd) 
70 
 
How to Clean your Symphony/Symphony-i 
IMPORTANT:  Do not use an abrasive cleaning agent or abrasive cloth when 
cleaning your Symphony/Symphony-i or damage to the touch screen may occur.  
Clean Symphony/Symphony-i as follows: 
SCREEN ACTION 
 1.  From the Home screen, press the “Tool 
Box” button.  The “Setup” screen is displayed. 
 
 
 
 4.  Press the Clean Screen button. A window 
indicating “Touch Screen will be disabled so 
that you may wipe the screen clean....
Start reading Honeywell keypad 81328132i User Manual

Related Manuals for Honeywell keypad 81328132i User Manual

All Honeywell manuals