Home > Honeywell > Alarm system > Honeywell Galaxy 3144 User Guide

Honeywell Galaxy 3144 User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Galaxy 3144 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							33
    ZONE REFERENCE TABLES
    e n o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P
    1 0 0 1
    2 0 0 1
    3 0 0 1
    4 0 0 1
    5 0 0 1
    6 0 0 1
    7 0 0 1
    8 0 0 1
    1 1 0 1
    2 1 0 1
    3 1 0 1
    4 1 0 1
    5 1 0 1
    6 1 0 1
    7 1 0 1
    8 1 0 1
    O I Ren o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P
    1
    2
    3
    4
    5
    6
    7
    8
    O I Ren o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P
    1
    2
    3
    4
    5
    6
    7
    8 
    						
    							34
    ALARM AND HELP MESSAGES
    Alarm In Progress
    The system is currently in alarm condition and must be cancelled by a valid PIN or
    keyswitch operation.
    Pa Reset Required
    After a PA (Personal Attack) zone has been activated, the system has to be reset by a
    high level code (such as a manager or engineer depending on the reset level setting).
    Manager Reset Required
    Following an alarm activation, the system requires to be reset by a manager level
    code.
     This message is displayed when a tamper alarm occurs.
    Engineer Reset Required
    The system has been programmed for engineer reset following an alarm activation.
    The engineer must be called to reset the system before the user can set the
    alarm.Tamper alarms usually require an engineer to visit the site to check all
    modules on the system.
    Alarm Cause Code
    Following an alarm activation, the system requires to be reset by user entry of an
    appropriate alarm cause code.
    No Entries
    This message appears if a user attempts to view or inspect the log and there is
    nothing in the log to be viewed or when the omit option is selected and there are no
    omittable zones on the system.
    Invalid Selection
    The option selected or value entered is illegal or out of range.
    Invalid Code
    The code entered is not a valid code registered in the system memory.
    Option Not Available
    This option is provided by the engineer, where it is specifically required. Attempting to
    select an option when it has not been provided results in the display of
    Technistore Reset
    Call the Alarm Monitoring Station and quote the five digit number displayed. Enter the
    number quoted by the monitoring station to reset the system.
    No Modules Added
    When exiting Engineer Mode the panel does not detect the change in the number of
    modules. Press esc to continue.NO MODULE ADDED
    ESC TO CONTINUE
    ALARM IN
    PROGRESS
    PA
    RESET REQUIRED 
    CALL MANAGER
    RESET REQUIRED
    CALL ENGINEER
    RESET REQUIRED
    NO ENTRIES
    INVALID
    OPTION
    CALL ALARM CO.
    QUOTE CODE XXXXX
    ALARM CAUSE CODE
    >
    OPTION NOT 
    AVAILABLE
    INVALID CODE 
    						
    							35
    INSTALLER DETAILS
    Name: -----------------------------------------------------------------------------------
    Address: ---------------------------------------------------------------------------------
    -------------------------------------------------------------------------------------------
    -------------------------------------------------------------------------------------------
    -------------------------------------------------------------------------------------------
    Telephone: ------------------------------------------------------------------------------
    Office Hours:---------------------------------------------------------------------------
    Other Times:---------------------------------------------------------------------------
    Account No.: ---------------------------------------------------------------------------
    APPENDIX 1 - NOTE FOR SWEDISH MARKET
    Resetting Using Alarm Cause Code
    This option is not normally used but, if enabled by the engineer, when a reset is required, the
    user must enter an alarm cause code to reset the system.
    If there are multiple alarm causes and/or multiple groups require to be reset, then the alarm
    cause code only has to be entered once. The user enters the most appropriate code as deter-
    mined on site. The cause code value should be determined in conjunction with the Alarm
    Receiving Centre (ARC). 
    						
    							36
    IU1-0033  Rev 2.0© Copyright Honeywell Security 
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell Galaxy 3144 User Guide