Honeywell Galaxy 3144 User Guide
Have a look at the manual Honeywell Galaxy 3144 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
33 ZONE REFERENCE TABLES e n o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P 1 0 0 1 2 0 0 1 3 0 0 1 4 0 0 1 5 0 0 1 6 0 0 1 7 0 0 1 8 0 0 1 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 O I Ren o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P 1 2 3 4 5 6 7 8 O I Ren o Zno i t c n u Fno i t p i r c s e Dem i h Cti m Otr a P 1 2 3 4 5 6 7 8
34 ALARM AND HELP MESSAGES Alarm In Progress The system is currently in alarm condition and must be cancelled by a valid PIN or keyswitch operation. Pa Reset Required After a PA (Personal Attack) zone has been activated, the system has to be reset by a high level code (such as a manager or engineer depending on the reset level setting). Manager Reset Required Following an alarm activation, the system requires to be reset by a manager level code. This message is displayed when a tamper alarm occurs. Engineer Reset Required The system has been programmed for engineer reset following an alarm activation. The engineer must be called to reset the system before the user can set the alarm.Tamper alarms usually require an engineer to visit the site to check all modules on the system. Alarm Cause Code Following an alarm activation, the system requires to be reset by user entry of an appropriate alarm cause code. No Entries This message appears if a user attempts to view or inspect the log and there is nothing in the log to be viewed or when the omit option is selected and there are no omittable zones on the system. Invalid Selection The option selected or value entered is illegal or out of range. Invalid Code The code entered is not a valid code registered in the system memory. Option Not Available This option is provided by the engineer, where it is specifically required. Attempting to select an option when it has not been provided results in the display of Technistore Reset Call the Alarm Monitoring Station and quote the five digit number displayed. Enter the number quoted by the monitoring station to reset the system. No Modules Added When exiting Engineer Mode the panel does not detect the change in the number of modules. Press esc to continue.NO MODULE ADDED ESC TO CONTINUE ALARM IN PROGRESS PA RESET REQUIRED CALL MANAGER RESET REQUIRED CALL ENGINEER RESET REQUIRED NO ENTRIES INVALID OPTION CALL ALARM CO. QUOTE CODE XXXXX ALARM CAUSE CODE > OPTION NOT AVAILABLE INVALID CODE
35 INSTALLER DETAILS Name: ----------------------------------------------------------------------------------- Address: --------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------- Telephone: ------------------------------------------------------------------------------ Office Hours:--------------------------------------------------------------------------- Other Times:--------------------------------------------------------------------------- Account No.: --------------------------------------------------------------------------- APPENDIX 1 - NOTE FOR SWEDISH MARKET Resetting Using Alarm Cause Code This option is not normally used but, if enabled by the engineer, when a reset is required, the user must enter an alarm cause code to reset the system. If there are multiple alarm causes and/or multiple groups require to be reset, then the alarm cause code only has to be entered once. The user enters the most appropriate code as deter- mined on site. The cause code value should be determined in conjunction with the Alarm Receiving Centre (ARC).