– 21 – Accessing Other Partitions (cont’d) ARM P 1 2 3 4 5 6 7 8 HIT 0-8 X X X - - X - - The prompt displays all the partitions. The user may only arm/disarm the partitions they are assigned access to. To select the partition(s) that are to be armed, enter the desired number 1-8. An X will appear under that partition. Entering a partition’s number again will delete the “X” and that partition will not arm when this prompt is exited. Pressing 0 will turn all partitions the user is assigned access to on/off. When completed, press ✳ to exit. All the partitions with the “X” will then arm/disarm. Global Arming Notes: • When performing a Global Arm, if there are faults in either partition, the system will enter a Summary Mode. Faulted zones in all the partitions will be displayed. These faults must be corrected or bypassed. This Summary Mode will end in approximately 120 seconds if no keys are pressed. • When performing a Global Disarm, if either of the partitions has a condition which would cause the keypad to beep (e.g., alarm memory or a trouble condition), the system enters a Summary Mode and displays the condition. This Summary Mode will end in approximately 120 seconds if no keys are pressed.
– 22 – Checking For Open Zones Using the ✳ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING section). Otherwise the keypad will display a Not Ready message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones. To show faulted zones: DISARMED - PRESS TO SHOW FAULTS Note: Some keypads light a green LED when the system is ready. If not lit, the system is not ready to be armed. READY 1. Do not enter security code, but simply press ✳ . FAULT 05 FRONT UPSTAIRS BEDROOM Typical fault display 2. DISARMED READY TO ARM Secure or bypass the zones displayed before arming the system. The Ready message will be displayed† when all protection zones have been either closed or bypassed. † NOTE: All or part of this message may be replaced by a customized message programmed by the installer. Bear this in mind whenever the instructions indicate that the DISARMED or READY message will be displayed.
– 23 – Displaying All Zone Descriptors Using the ✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in your system. The abbreviated instructions for the READY key will appear first, followed by the zone descriptors. Displaying all descriptors is useful when you need to know the zone number of a particular zone, as when bypassing zones. The Disarmed-Ready to arm message must be displayed before zone descriptors can be displayed. READY Press the ✳ key and hold down for at least 5 seconds.
– 24 – Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful. Note: The system will not allow fire or emergency zones to be bypassed. To bypass zones, the system must be disarmed first. BYPASS 1. Enter your security code and press 6 . 2. Enter zone number(s) for the zones to be bypassed (e.g., 01, 02, 03, etc.). Important! All single-digit numbers must be preceded by “0” (for example, enter 01 for zone 1). 3. BYPASS 07 FRONT UPSTAIRS BEDROOM Typical bypass message When finished, the keypad will display the word BYPASS along with each bypassed zone number. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses. 4. DISARMED BYPASS READY TO ARM Arm the system as usual when the keypad displays ready to arm message.
– 25 – Bypassing Protection Zones (cont’d) Quick Bypass Your system allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. Note: All bypasses are removed when an OFF sequence (security code plus OFF) is performed. To use the Quick Bypass feature: BYPASS 1. Enter your security code and press 6 then press # . 2. BYPASS 07 FRONT UPSTAIRS BEDROOM Typical bypass message In a few moments, all open zones will be displayed along with the word BYPASS. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses. 3. DISARMED BYPASS READY TO ARM Arm the system as usual when the keypad displays the ready to arm message. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. Displaying Bypassed Zones For determining what zones have been previously bypassed. Bypassed zones can be displayed only when system is disarmed. BYPASS 1. Enter your security code and press 6 . 2. Wait for all bypassed zones to be sequentially displayed.
– 26 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use the entrance door later. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur. Check with your installer for a list of the zones that are bypassed during the STAY mode. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section) STAY 1. Enter your security code and press 3 2. ARMED ***STAY*** ZONE BYPASSED The keypad beeps three times, displays the armed message. Note: ZONE BYPASSED in this display simply indicates that some zones of protection are not armed when using STAY mode.
– 27 – Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Use this key when you are staying home and do not expect anyone to use the entrance door. When armed in INSTANT mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. The alarm will also sound immediately if anyone opens the entrance door. Check with your installer for a list of the zones that are bypassed during the INSTANT mode. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section) INSTANT 1. Enter your security code and press 7 2. ARMED INSTANT ZONE BYPASSED The keypad beeps three times, displays the armed message. Note: ZONE BYPASSED in this display simply indicates that some zones of protection are not armed when using INSTANT mode.
– 28 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also reenter through the entrance door, but must disarm the system within the entry delay period or an alarm will occur. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section) AWAY 1. Enter your security code and press 2 . 2. ARMED **AWAY** YOU MAY EXIT NOW The keypad will beep twice and will display the armed message. Note: The YOU MAY EXIT NOW portion of the message disappears when exit delay expires.
– 29 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will be sounded as soon as someone reenters. Close all perimeter windows and doors before arming (see CHECKING FOR OPEN ZONES section). MAXIMUM 1. Enter your security code and press 4 . 2. ARMED *MAXIMUM* YOU MAY EXIT NOW The keypad will beep twice and will display the armed message. Note: The YOU MAY EXIT NOW portion of the message disappears when exit delay expires.
– 30 – Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See SUMMARY OF AUDIBLE NOTIFICATION section for information which will help you to distinguish between FIRE and BURGLARY alarm sounds. IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. To disarm the system and silence burglary or fire alarms: OFF 1. Enter your security code and press 1 . DISARMED READY TO ARM 2. The Ready message will be displayed (if no alarms have occurred while armed) and the keypad will beep once to confirm that the system is disarmed. Memory of Alarm The keypad displays the zone number and type of alarm for any zone that has an alarm condition. These messages will remain displayed until cleared by a user. If an alarm has occurred, note the zone number displayed on the keypad and repeat step 1 above to clear the Memory of Alarm and restore the Ready message display. If the Ready message will not display, go to the displayed zone and remedy the fault (close windows, etc.). If the fault cannot be remedied, notify the alarm agency. If the system was armed when the alarm occurred, repeat step 1 twice: once to disarm the system, a second time to clear the display.