– 41 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a protected perimeter door or window is opened, and the Not Ready message will be displayed. Pressing the READY key will display the open protection points. Note that Chime mode can be activated only when the system is disarmed. 1. To turn Chime Mode on, enter the security code and press 9 . CHIME MODE ON The CHIME MODE ON message will appear for about 2 seconds then disappear. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds. 2. To turn Chime Mode off, enter the security code and press 9 again. CHIME MODE OFF The CHIME MODE OFF message will appear for about 2 seconds then disappears. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds.
– 42 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their monitoring agency or installer. When a message is waiting to be viewed, the message shown below will appear. MESSAGE. PRESS 0 FOR 5 SECS. 1. Press and hold down 0 key for 5 seconds. 2. The message could take up to four screens to display all the information available. NOTE: Any message sent by the central station downloader may be viewed at any partition’s keypad.
– 43 – Panic Keys (For Manually Activating Silent and/or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, and Personal Emergency. See your installer for the function(s) that may have been programmed for your system. Active Panic Functions (Your installer should note which function(s) is active in your system.) Keys Zone Function 1 and * 995 3 and # 996 * and # 999 A 995 B 999 C 996 To use a paired key panic function, simply press both keys of the assigned pair at the same time. If your keypad(s) have lettered keys for panic functions, press the designated key and hold down for at least 2 seconds to activate the panic function. A silent emergency sends a silent alarm signal to the central station, but there will be no audible alarms or visual displays. An audible emergency sends an emergency message to the central station (if connected) and will sound a loud, steady alarm at your keypad and at any external sounders that may be connected (ALARM plus a zone number would also be displayed). A personal emergency alarm sends an emergency message to the central station (if connected) and will sound at Keypads, but not at external Notification Appliance Circuits. (ALARM plus a zone number would also be displayed.)
– 44 – Relay Control General Information Your system may be set up using a relay so that a door (such as in a lobby) can be unlocked momentarily using a keypad command. Ask your installer if this has been done in our system. Executing To activate the relay enter your security code + [0] at the keypad. The door will unlock for 2 seconds.
– 45 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from a keypad. Ask your installer if this has been done in your system. To activate relays from a keypad, enter 4-digit security code + [#] +70. Follow the keypad prompts described below. NOTE: Your installer may have restricted the use of this function. Please check with your installer. ENTER DEVICE NO. 00=QUIT 01 Enter the 2-digit number of the device to be activated. Note that if an invalid number is entered, the system will simply ask you to reenter the number. NN DEVICE IS OFF HIT 0=OFF , 1=ON Press 0 or 1 to turn the device off or on respectively. nn represents the 2-digit device number and voice descriptor is the relay voice descriptor programmed by the installer. NN DEVICE IS OFF HIT THE ✴ KEY From a keypad, press ✴ to continue. The ENTER DEVICE NO. prompt will appear.
– 46 – Using Schedules Delaying the Closing Time Your systems programmed schedules may automatically arm the system at a predetermined time. In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. To delay the closing time: 1. Enter your security code (master or manager authority levels only). 2. Press the # key, followed by 82. 3. A menu prompt will be displayed, asking for the number of hours of delay. CLOSING DELAY? KEY 0-2 HOURS Enter the desired number of hours of delay, 1 or 2. The system automatically exits this mode after entry. Note that the delay is from the scheduled closing time, not from the time the command is entered. IMPORTANT: The selected delay cannot be reduced once it is set. A 1- hour delay can be increased to 2 hours, though. 4. The system will automatically send a message to the central station informing them that the programmed schedule has been changed. Temporary Open/Close Schedules Temporary schedules allow you to override the normal schedules programmed by the installer. Temporary schedules can be in effect for up to one week, and take effect as soon as they are programmed. They are comprised of an arming (closing) time window and a disarming (opening) time window. A time window is simply a defined period of time, at the end of which arming or disarming will occur. Before programming, use a worksheet similar to the one below to plan your schedule. This will make it easier when actually programming the schedule. Arm/Disarm Mon Tue Wed Thu Fri Sat Sun Windows Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM
– 47 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary schedules can be reused at later dates simply by scrolling (by pressing #) to the DAYS? prompt (described below) and activating the appropriate days. This should be considered when defining daily time windows. Note that only users with authority level of manager or higher can program temporary schedules. To program temporary schedules: 1. Enter your security code. 2. Press the # key followed by 81. 3. The following prompts will appear. MON DISARM WIND. 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for Mondays disarm window. Enter the desired hour. Press * to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is changed by hitting any key, 0-9, while the cursor is under the letter A/P position. Repeat for the stop time entry. Press the * key to move to the arming window for Monday. Press # to move to the next screen display without making changes. MON ARM WINDOW 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for the arm window. Repeat the previous steps to enter the start and stop time for Mondays arming window. TUE DISARM WIND. 07:45AM 08:45AM After the windows for that day have been completed, the system will prompt for disarm and arm time windows for the next day. Repeat the procedure for all days of the week. When all of the days have been completed, the system will ask which days are to be activated.
– 48 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the temporary schedule to be customized to a particular weeks needs. To select the days that are to be activated, enter the desired number 1-7 (Monday = 1). An X will appear under that day, indicating the previously entered schedule for that day is active. Entering a days number again will deactivate that day. Pressing 0 will turn all days on/off. The temporary schedule will only be in effect for the days which have the letter x underneath them. As the week progresses, the days are reset to the inactive state. When completed, press * to exit the temporary schedule entry mode.
– 49 – Programming Device Timers General Information Device timers consist of an ON time and an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed). Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set to turn the porch lights on at 7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air conditioner Monday-Friday at 4:30pm to cool the premises before you arrive at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If desired, different timers can control the same device. For example, timer 2 could be used Monday-Friday as in the previous example, and timer 3 could be set to turn the air conditioner on and off at different times Saturday and Sunday. To enter the device timer menu mode: Enter your security code, then press the # key followed by 83. OUTPUT TIMER # ? 01-20,00=QUIT 01 Up to 20 timers can be programmed. A number 1- 20 identifies each timer. Enter the desired timer number to be programmed (1-20). Press * to accept entry. 06 07:00P 11:45P PORCH LITE 04 If that timer number has already been programmed, a summary screen will appear. In this example: 06 = Timer # 04 = Output Device # affected by this timer PORCH LITE = Output Descriptor for Device 4 07:00PM = Start Time; 11:45PM = Stop Time Press * to continue. See your installer for device numbers. 00 ENTER OUTPUT# 00 Enter the desired output device number (1-96). As the number is entered, the devices description will appear. To delete a previously programmed timer, enter 00 as the output number.
– 50 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something ON for the days selected below. (Ex. using one timer to turn lights on one day and using another timer to turn them off on another day). 00 OFF TIME ? 00:00 PM Enter the time you want the device turned off using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something OFF for the days selected below. (Ex. using one timer to turn lights on one day and using another timer to turn them off on another day). 00 DAYS? MTWTFSS HIT 0-7 X X Select the days on which the device is to be activated by entering 1-7 (Monday = 1). An X will appear under that day, indicating the output for that day is active. Entering a days number again will deactivate that day. Pressing 0 will turn all days on/off. The outputs will only be in effect for the days that have the letter x underneath them. As the week progresses, the days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press * to continue. 00 PERMANENT ? 0 = NO, 1 = YES 0 Answering 1 (YES) means the system executes this timer continuously. Answering 0 (NO) means the system executes each days output only once.