    – 31 – 
    Bypassing Protection Zones (cont’d) 
    Quick Bypass 
    Your system allows you to easily bypass all open (faulted) zones without 
    having to enter zone numbers individually.  
    Note: All bypasses are removed when an OFF sequence (security code plus 
    OFF) is performed. 
    To use the Quick Bypass feature: 
      BYPASS 
    1.  Enter your security code and press  6  then press  # . 
    2. BYPASS  007 FRONT 
    UPSTAIRS BEDROOM 
    Typical bypass message 
    In a few moments, all open zones will be 
    displayed along with the word BYPASS. Wait 
    for these zones to be displayed before arming. 
    Arming the system before bypassed zones are 
    displayed eliminates all bypasses. 
    3. DISARMED BYPASS 
    READY TO ARM 
    Arm the system as usual when the keypad 
    displays the ready to arm message. Bypassed 
    zones are unprotected and will not cause an 
    alarm when violated while your system is 
    armed. 
    Displaying Bypassed Zones 
    For determining what zones have been previously bypassed. Bypassed zones 
    can be displayed only when system is disarmed. 
      BYPASS 
    1.  Enter your security code and press  6  . 
    2.  Wait for all bypassed zones to be sequentially displayed. 
     
     
     
     
     
     
      
    						
    							 
     
    – 32 – 
    Bypassing Protection Zones (cont’d) 
    Group Bypass 
    Your system allows you to easily bypass a group of zones without having to 
    enter zone numbers individually. The system provides up to 15 groups. There 
    is no limit to the number of zones that may be assigned to any one group. 
    Check with your installer for a list of zones assigned to the group(s). 
    NOTES:  
    All bypasses are removed when an OFF sequence (security code plus OFF) is 
    performed. 
    Users must be assigned the following attributes to perform the group bypass 
    function: 
    • Enabled for group bypassing 
    • Access to the partition(s) containing the zones being bypassed 
    • Global arming capability. 
    To use the Group Bypass feature: 
      BYPASS 
    1.  Enter your security code and press  6  then press   ✳  then enter the 
    group number (01-15). 
    2. BYPASS  007 FRONT 
    UPSTAIRS BEDROOM 
    Typical bypass message 
    In a few moments, all the zones in the group 
    will be displayed along with the word BYPASS. 
    Wait for these zones to be displayed before 
    arming. Arming the system before bypassed 
    zones are displayed eliminates all bypasses. 
    3. DISARMED BYPASS 
    READY TO ARM 
    Arm the system as usual when the keypad 
    displays the ready to arm message. Bypassed 
    zones are unprotected and will not cause an 
    alarm when violated while your system is 
    armed. 
     
     
     
     
     
     
      
    						
    							 
     
    – 33 – 
    Arming Perimeter Only 
    (With Entry Delay ON) 
    Using the   3  STAY key 
    Use this key when you are staying home, but might expect someone to use 
    the entrance door later. 
    When armed in STAY mode, the system will sound an alarm if a protected 
    door or window is opened, but you may otherwise move freely throughout the 
    premises. Late arrivals can enter through the entrance door without causing 
    an alarm, but they must disarm the system within the entry delay period or 
    an alarm will occur.  
    The system provides three STAY modes. STAY mode 1, 2, and 3. When 
    activated, STAY modes 1 and 2 automatically bypass specific zones assigned 
    by your installer to each of the STAY modes. STAY mode 3, when activated, 
    automatically bypasses all zones assigned to STAY modes 1 AND 2. Check 
    with your installer for a list of the zones that are bypassed during each STAY 
    mode. 
    Close all perimeter windows and doors before arming (see 
    CHECKING FOR OPEN ZONES section) 
      STAY 
    1.  Enter your security code and press  3   +  1  for STAY Mode 1. 
      Enter your security code and press  3 
      +  2  for STAY Mode 2. 
      Enter your security code and press  3 
      +  3  for STAY Mode 3. 
    NOTE: If none of the zones in a partition are assigned to Stay mode 2, then 
    when the user enters [User Code] + [3] (STAY), all zones assigned to Stay 
    mode 1 are automatically bypassed. 
    2. ARMED ***STAY 1* 
    ZONE BYPASSED 
    The keypad beeps three times, displays the 
    armed message, and indicates which STAY 
    mode (1, 2 or 3). 
    NOTE: ZONE BYPASSED in this display 
    simply indicates that some zones of protection 
    are not armed when using STAY mode. 
      
    						
    							 
     
    – 34 – 
    Arming Perimeter Only 
    (With Entry Delay ON) (cont’d) 
    Auto-STAY Arming 
    Auto-stay allows the system to automatically bypass certain zones if upon 
    arming none of the entry/exit zones are faulted during the exit delay time (no 
    one exits the premises). The system provides an option to set each burglary 
    zone for Auto-stay. All zones enabled for auto-stay except for perimeter and 
    day/night types of zones, has exit delay time when the partition is armed. 
    Check with your installer for the zones assigned for Auto-STAY.  
    NOTES: 
    • Auto-STAY applies to all four arming modes (AWAY, STAY, INSTANT 
    and MAXIMUM). 
    • Arming the partition AWAY via an RF transmitter overrides the Auto-
    stay feature (partition will not bypass zones programmed for auto-stay). 
     
     
      
    						
    							 
     
    – 35 – 
    Arming Perimeter Only 
    (With Entry Delay OFF) 
    Using the   7  INSTANT Key 
    Use this key when you are staying home and do not expect anyone to use the 
    entrance door. 
    When armed in INSTANT mode, the system will sound an alarm if a 
    protected door or window is opened, but you may otherwise move freely 
    throughout the premises. The alarm will also sound immediately if anyone 
    opens the entrance door. 
    The system provides three INSTANT modes: INSTANT mode 1, 2, and 3. 
    INSTANT modes 1 and 2, when activated, automatically bypass specific 
    zones assigned by your installer to each of the INSTANT modes. INSTANT 
    mode 3, when activated, automatically bypasses all zones assigned to 
    INSTANT modes 1 and 2. Check with your installer for a list of the zones 
    that are bypassed during each INSTANT mode. 
    Close all perimeter windows and doors before arming (see 
    CHECKING FOR OPEN ZONES section) 
       INSTANT 
    1.  Enter your security code and press  7   +  1  for INSTANT Code 1. 
      Enter your security code and press  7 
      +  2  for IINSTANT Mode 2. 
      Enter your security code and press  7 
      +  3  for INSTANT Mode 3. 
    NOTE: If none of the zones in a partition are assigned to INSTANT mode 2, 
    then when the user enters [User Code] + [7] (INSTANT), all zones assigned 
    to INSTANT mode 1 are automatically bypassed. 
    2. ARMED *INSTANT1 
    ZONE BYPASSED 
    The keypad beeps three times, displays the 
    armed message and indicates which INSTANT 
    mode (1, 2, or 3).  
    NOTE: ZONE BYPASSED in this display 
    simply indicates that some zones of protection 
    are not armed when using RSTART mode. 
      
    						
    							 
     
    – 36 – 
    Arming All Protection 
    (With Entry Delay ON) 
    Using the   2  AWAY Key 
    Use this key when no one will be staying on the premises. 
    When armed in AWAY mode, the system will sound an alarm if a protected 
    door or window is opened, or if any movement is detected inside the premises. 
    You may leave through the entrance door during the exit delay period 
    without causing an alarm. You may also reenter through the entrance door, 
    but must disarm the system within the entry delay period or an alarm will 
    occur. 
    Close all perimeter windows and doors before arming (see 
    CHECKING FOR OPEN ZONES section) 
      AWAY 
    1.  Enter your security code and press  2  . 
    2
    . ARMED **AW AY** 
    YOU MAY EXIT NOW 
    The keypad will beep twice and will display the 
    armed message.  
    NOTE: The YOU MAY EXIT NOW portion of 
    the message disappears when exit delay 
    expires. 
     
     
     
     
     
     
     
     
     
      
    						
    							 
     
    – 37 – 
    Arming all Protection 
    (with Entry Delay OFF) 
    Using the   4  MAXIMUM Key 
    Use this key when the premises will be vacant for extended periods of time 
    such as vacations, etc., or when no one will be moving through protected 
    interior areas. 
    When armed in MAXIMUM mode, the system will sound an alarm if a 
    protected door or window is opened, or if any movement is detected inside the 
    premises. You may leave through the entrance door during the exit delay 
    period without causing an alarm, but an alarm will be sounded as soon as 
    someone reenters. 
    Close all perimeter windows and doors before arming (see Checking 
    for Open Zones section). 
      MAXIMUM 
    1.  Enter your security code and press  4  . 
    2. ARMED *MAXIMUM* 
    YOU MAY EXIT NOW 
    The keypad will beep twice and will display the 
    armed message.  
    NOTE: The YOU MAY EXIT NOW portion of 
    the message disappears when exit delay 
    expires. 
     
     
     
     
     
     
     
     
     
     
     
     
      
    						
    							 
     
    – 38 – 
    Quick Exit 
    Using the   #  +   9  Keys 
    The Quick Exit feature allows you to exit the armed partition without having 
    to disarm and then rearm the partition. 
    To Quick Exit the premises: 
    1. Press the  # 
     key and then press the  9  key. 
    2. The system will sound the exit beeps, if enabled, and will give you the 
    programmed exit delay time to leave the premises. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
      
    						
    							 
     
    – 39 – 
    Disarming and Silencing Alarms 
    Using the   1  OFF Key 
    The OFF key is used to disarm the system and to silence alarm and trouble 
    sounds. See Summary of Audible Notification section for information that 
    will help you to distinguish between FIRE and BURGLARY alarm sounds. 
    IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter 
    the premises, but call the police from a nearby safe location. If you return after an 
    alarm has occurred and the main sounder has shut itself off, the keypad will beep 
    rapidly upon entering, indicating that an alarm has occurred during your absence. 
    LEAVE the premises IMMEDIATELY and CONTACT THE POLICE from a 
    nearby safe location. 
    To disarm the system and silence burglary or fire alarms: 
      OFF 
    1.  Enter your security code and press  1  . 
    DISARMED 
    READY TO ARM 
    2.  The Ready message will be displayed (if no alarms have occurred while 
    armed) and the keypad will beep once to confirm that the system is 
    disarmed. 
    Memory of Alarm 
    The keypad displays the zone number and type of alarm for any zone that 
    has an alarm condition. These messages will remain displayed until cleared 
    by a user. If an alarm has occurred, note the zone number displayed on the 
    keypad and repeat step 1 above to clear the Memory of Alarm and restore 
    the Ready message display. If the Ready message will not display, go to the 
    displayed zone and remedy the fault (close windows, etc.). If the fault cannot 
    be remedied, notify the alarm agency. 
    If the system was armed when the alarm occurred, repeat step 1 twice: once 
    to disarm the system, a second time to clear the display. 
     
     
      
    						
    							 
     
    – 40 – 
    Using the Keyswitch 
    General 
    Your system may be equipped with a keyswitch for use when arming and 
    disarming a partition. A red and green light on the keyswitch plate indicate 
    the status of your system as follows: 
     Green Light:  Lights when the system is disarmed and ready to be 
    armed (no open zones). If the system is disarmed and the 
    green light is off, it indicates the system is not ready (one or 
    more zones are open). 
     Red Light:  Lights when system is armed or memory of alarm exists. 
     Lit Steady: Partition is armed in AWAY mode. 
     Slow Flashing: Partition is armed in STAY mode. 
     Rapid Flashing: Memory of alarm, indicating an alarm has occurred. 
    Arming 
    To arm in the AWAY mode, turn the key to the right for 1 second and 
    release. Keypads will beep twice and the 
    red light will stay on steady. 
    To arm in the STAY mode, turn the 
    key to the right and hold for longer than 
    10 seconds, then release. Keypads will 
    beep three times and the red light will 
    flash slowly. 
    Disarming 
    To disarm the partition, turn the key 
    to the right and release. If an alarm has 
    occurred, the red light will be flashing 
    rapidly (memory of alarm). 
    NOTE: Your system may be 
    programmed to use the keyswitch to 
    silence fire alarms without affecting the 
    status of the burglary portion of the 
    system. Check with your installer to see 
    if this feature has been enabled. 
     
    GREEN RED
    keyswitch-001-V1  
    						