Page 41
– 41 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momentarily or for a specific period of time, using a keypad command. Ask your installer if this has been done in our system. Executing There are several entries that can be entered at the keypad to activate this command: 1. Enter your security code + [0]. The door will unlock for 2 seconds. 2. Enter your security code + [#] + 73, or security code...
Page 42
– 42 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4285 or 4286 VIP module is used). Ask your installer if this has been done in your system. To activate relays from a keypad, enter 4-digit security code + [#] +70. Follow the keypad prompts described below. To activate relays using a telephone and 4285 or 4286 VIP module, first...
Page 43
– 43 – Using Schedules Delaying the Closing Time Your systems programmed schedules may automatically arm the system at a predetermined time. In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. To delay the closing time: 1. Enter your security code (master or manager authority levels only). 2. Press the # key, followed by 82. 3. A menu prompt will be displayed,...
Page 44
– 44 – Using Schedules (cont’d) Before programming temporary schedule, use a worksheet similar to the one below to plan your schedule. This will make it easier when actually programming the schedule. Arm/Disarm Mon Tue Wed Thu Fri Sat Sun Windows Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Programming Temporary Schedules Temporary schedules only affect the partition from...
Page 45
– 45 – Using Schedules (cont’d) MON ARM WINDOW 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for the arm window. Repeat the previous steps to enter the start and stop time for Mondays arming window. TUE DISARM WIND. 07:45AM 08:45AM After the windows for that day have been completed, the system will prompt for disarm and arm time windows for the next day. Repeat the procedure for all days of the week. When all of the days have been...
Page 46
– 46 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed). Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set...
Page 47
– 47 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the [ ✴] key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something ON for the days selected below. (ex. using one timer to turn lights on one day and using another timer to turn them off on another day). 00 OFF TIME ?...
Page 48
– 48 – Event Log Procedures General Information The system has the ability to record various events in a history log wherein each event is recorded in one of five categories (listed below), with the time and date of its occurrence. The Event Log holds up to 224 events, with the oldest event being replaced by the logging of any new event after the log is full. Using an alpha keypad, the Event Log can be viewed one category at a time, or can display all events, regardless of category (ALL...
Page 49
– 49 – Event Logging Procedures (cont’d) ALARM EVENT LOG Displays time and date for zones that have either caused an alarm or have been restored in the selected partition. CHECK EVENT LOG Displays time and date for zones that have caused a trouble or supervisory condition in the selected partition. BYPASS EVENT LOG Displays time and date for zones that have been bypassed in the partition. OPEN EVENT LOG Displays time, date and user number for each arming and disarming of the system...
Page 50
– 50 – Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, that allows each protection point to be checked for proper operation. 1. Disarm the system and close all protected windows, doors, etc. READY should be displayed. 2. Enter your security code and press the 5 TEST key. 3. The external sounder should sound for 3 seconds and then turn off. If the sounder does not sound, it may be due to dialer communication activity....