Home > Honeywell > Control panel > Honeywell control panel LYNXREN User Manual

Honeywell control panel LYNXREN User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell control panel LYNXREN User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
     
     
     
     
     
     
     
     
     
        
    ADEMCO LYNXR-EN 
      Security System
      
     
    User Guide  
     
     
     
     
     
     
     
    AWAY OFF
    STAY
    AUXLIGHTS ON RECORD
    LIGHTS OFF
    STATUSTEST VOLUME
    CODE
    NO DELAYBYPASSPLAY
    CHIME
    FUNCTION DELETE ESCAPE
    ADD
    SELECT
    ARMED
    READY
    4
    5
    6
    7
    8
    9
    0
    # 1
    2
    3
     
     
     
     
     
     
     
     
    K5964V3bx  5/04  Rev. A   
    						
    							– 2 – 
     
    Your Honeywell security system is designed for use with devices manufactured or approved by 
    Honeywell for use with your security system.  Your Honeywell security system is not designed for 
    use with any device that may be attached to your security systems keypad or other 
    communicating bus if Honeywell has not approved such device for use with your security system.  
    Use of any such unauthorized device may cause damage or compromise the performance of your 
    security system and affect the validity of your Honeywell limited warranty.  W hen you purchase 
    devices that have been manufactured or approved by Honeywell, you acquire the assurance that 
    these devices have been thoroughly tested to ensure optimum performance when used with your 
    Honeywell security system.    
    						
    							– 3 – 
      
    TABLE OF CONTENTS
    TABLE OF CONTENTSTABLE OF CONTENTS TABLE OF CONTENTS 
        
     
    SYSTEM OVERVIEW................................................................................................................................5 
     Features ................................................................................................................................................. 5 
     General Operation ................................................................................................................................. 7 
      Quick View of System Functions .......................................................................................................... 9 
      About the Master Keypad ................................................................................................................... 11 
      Master Keypad Definitions ................................................................................................................. 12 
      About the Display and Indicators ....................................................................................................... 14 
    SECURING THE PREMISES................................................................................................................ 15 
      Checking System Status ..................................................................................................................... 15 
      Arming the System .............................................................................................................................. 16 
     Entry/Exit Delays ................................................................................................................................ 18 
      Disarming the System ......................................................................................................................... 19 
      Bypassing Protection Zones ................................................................................................................ 20 
      Panic Keys / Chime Mode.................................................................................................................... 21 
    USER FUNCTIONS................................................................................................................................. 22 
     Paging Feature .................................................................................................................................... 22 
      “Follow Me” Announcement Feature .................................................................................................. 23 
      Using Powerline Carrier Device Commands (Lights On/Lights Off keys)........................................ 25 
      Message Recording/Playback/Volume Control ................................................................................... 26 
     Aux Function ....................................................................................................................................... 28 
     Clock/Calendar .................................................................................................................................... 29 
      Scheduling User Interface................................................................................................................... 31 
      Remote Phone Control Feature........................................................................................................... 36 
      Speaker Phone Feature ....................................................................................................................... 38 
    FIRE ALARM SYSTEM........................................................................................................................... 40 
     General Information ............................................................................................................................ 40 
      National Fire Protection Association’s Smoke Detector Recommendations ..................................... 41 
     Emergency Evacuation........................................................................................................................ 42 
    SYSTEM FUNCTIONS............................................................................................................................ 43 
     Security Codes ..................................................................................................................................... 43 
      Testing the System .............................................................................................................................. 44 
     Trouble Messages ................................................................................................................................ 45 
      Maintaining Your System ................................................................................................................... 46 
    SUMMARY OF AUDIBLE NOTIFICATION........................................................................................ 47 
    FCC STATEMENTS................................................................................................................................. 49 
    OWNER’S INSURANCE PREMIUM CREDIT REQUEST................................................................ 53 
    INDEX........................................................................................................................................................ 55 
    LIMITATIONS OF THIS ALARM SYSTEM........................................................................................ 57 
    ONE YEAR WARRANTY........................................................................................................................ 58 
     
     Congratulations on your ownership of a Honeywell Security System. You have made a wise 
    decision in choosing it, for it represents the latest in security protection technology today. 
    Honeywell is the worlds largest manufacturer of security systems, and millions of premises 
    are protected by Honeywell products.  
    						
    							– 5 – 
    SYSTEM OVE
    SYSTEM OVESYSTEM OVE SYSTEM OVERVIEW
    RVIEWRVIEW RVIEW 
        
    Features 
    General Information 
    This system offers you three forms of protection: burglary, fire, and emergency, depending on the 
    configuration of your system. The system consists of a master keypad for controlling system operation, 
    various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or 
    combustion detectors to provide early fire warning. In addition, optional wireless keypads may have 
    been installed to allow you to control the system away from the master keypad. The system may also be 
    controlled from a remote telephone and can be used as a speaker phone. 
    The system uses microcomputer technology to monitor all protection zones and system status, display 
    appropriate information on the keypad display, and initiate appropriate alarms. Your system may also 
    have been programmed to automatically send alarm or status messages over the phone lines to a 
    central alarm monitoring station, and may also be capable of two-way voice communication with the 
    central station.  
     
    The user features of this security system are listed below. Ask your installer which features 
    have been programmed for your system. 
    • STAY and AWAY arming modes: By using these modes you can protect either the perimeter only, 
    or the entire premises. 
    • 3 panic key functions: Designated keys allow you to manually activate fire, personal emergency, or 
    silent alarms. Refer to the PANIC KEYS section for detailed information. 
    • Paging feature: If programmed by your installer this feature alerts you to certain system conditions 
    by displaying code numbers that indicate the type of condition that has occurred. In addition, 
    pressing the AUX key can send a predefined message to your pager, if programmed to do so (see AUX 
    key function below). Refer to the PAGING FEATURE section for detailed information. 
    • Follow me system announcements:  Allows the LYNXR-EN to dial a number, programmed by 
    your installer, and deliver system announcements.  
    • Follow me reminder announcements:  Allows the LYNXR-EN to dial a number, that you have 
    specified, at a programmed time and day and deliver a message programmed by your installer.  
    • Real-time clock: Keypad displays current time. Refer to the CLOCK/CALENDAR section for 
    procedures for setting the time. 
    • Voice announcement of system status: The master keypad’s built-in speaker announces system 
    status at the press of a key. Refer to the CHECKING SYSTEM STATUS section for detailed 
    information. 
    • Message center: The system allows recording and play back of brief messages. Refer to the 
    RECORDING/PLAYBACK MESSAGES section for procedures. 
    • Device activation: Designated keys allow you to turn lights and/or other devices on and off. In 
    addition, some devices (e.g., a light) may be programmed to activate automatically as a result of a 
    system event such as an alarm or trouble condition. Refer to the USING POWERLINE CARRIER 
    DEVICE COMMANDS section for detailed information. 
      
    						
    							– 6 – 
    SYSTEM OVERVIEW
    SYSTEM OVERVIEWSYSTEM OVERVIEW SYSTEM OVERVIEW 
        
    Features 
     
    • AUX key function: Designated key lets you activate a predefined series of keystrokes with a single 
    press of the 
    AUX key plus user code, or manually send a pager message. It will also allow you to 
    manually send a voice message to phone number that has been programmed by your installer. Ask 
    your installer which of these features has been assigned to the 
    AUX key in your LYNXR-EN. Refer 
    to the AUX FUNCTION section for detailed information. 
    • Scheduling feature: Allows you to schedule the automatic activation or deactivation of X-10 devices 
    or program events (e.g. alarm clock, reminder, and latch key). 
    • Two-way voice: Allows the central station to listen, talk to or conduct two-way conversations with 
    individuals on the premises Refer to the TWO-WAY VOICE section for detailed information.  
    • Phone Control: Provides a remote interactive phone capability that permits access to the security 
    system from any off-site touch-tone telephone. 
    • Speaker Phone Operation: The system is capable of operating as a speaker phone allowing hands 
    free telephone conversation. 
    • Security Codes: The system is capable of supporting an Installer code, Master user code and six 
    additional User codes. Refer to the SECURITY CODES section for detailed information.  
    						
    							– 7 – 
     
        
    SYSTEM 
    SYSTEM SYSTEM  SYSTEM OVERVIEW
    OVERVIEWOVERVIEW OVERVIEW 
        
    General Operation  
    Zones 
    Your systems sensing devices have been assigned to various zones. For example, the sensing device 
    on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master 
    bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble 
    condition occurs. 
     
    U
    UU U
    L
    LL L 
        
     LYNXR-EN is not intended for UL985 Household Fire applications unless a 24-hour 
    backup battery (P/N LYNXRCHKIT-HC) is installed. 
     
    Fire Protection 
    The fire protection portion of your security system (if used) is always active and will sound an alarm if 
    a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information 
    concerning fire protection, smoke detectors and planning emergency exit routes from the premises. 
    Burglary Protection 
    Your system provides two modes of burglary protection: STAY and AWAY. STAY mode protects the 
    perimeter only, allowing you to freely move within inside the premises. AWAY mode protects the entire 
    system. Both modes provide an entry delay time that allows you to reenter the premises without setting 
    off an alarm. For additional security, you can turn the entry delay off when arming the system by using 
    the 
    NO DELAY key in combination with the desired arming key. The system also allows you to bypass 
    selected zones before arming the system, if desired. Refer to the BYPASSING PROTECTION ZONES 
    section. The system also provides a CHIME mode, for alerting users to the opening of protected doors 
    and windows while the system is disarmed. 
    You must turn on (arm) the burglary protection portion of your system before it will sense burglary 
    alarms.  To arm the system, enter your user code then press the desired arming key (AWAY or STAY). 
    Refer to the ARMING THE SYSTEM section for detailed procedures and information. 
    Security Codes 
    At the time of installation, you were assigned a personal 4-digit security or “master user” code. You 
    must enter the user code when arming and disarming the system, and when performing other system 
    functions. As an additional security feature, other users who do not need to know your code can be 
    assigned up to 6 different security codes. Refer to the SECURITY CODES section for procedures on 
    adding security codes to the system. 
    Alarms 
    When an alarm occurs, the keypad and external sounders will sound for about 15-seconds, and the 
    keypad will display the zone(s) causing the alarm. After 15-seconds, the siren stops temporarily and 
    voice announcements of the zones in alarm begins. When these zones have been announced, the siren 
    sounds again and the cycle repeats itself, until the system is disarmed  (code + OFF) or  
    						
    							– 8 – 
    SYSTEM OVERVIEW
    SYSTEM OVERVIEWSYSTEM OVERVIEW SYSTEM OVERVIEW 
        
    General Operation 
     
    until alarm bell timeout occurs. If your system is connected to a central monitoring station, an alarm 
    message will be sent. To stop the alarm sounding, simply disarm the system. The zone(s) causing the 
    alarm remain displayed indicating memory of alarm. Refer to the DISARMING THE SYSTEM section 
    for information about clearing the memory of alarm display 
     
    Two-Way Voice Feature 
    The LYNXR-EN supports voice dialog between an operator at the central station and an individual at 
    the premises. This feature allows the central station to listen, talk to or conduct a two-way conversation 
    with an individual(s) at the premises and allows the operator to gather information about the nature 
    and location of the alarm that may be helpful in responding to fire, police or rescue departments. If the 
    Two-way Voice Feature has been programmed and an alarm condition is detected the system sends an 
    alarm message to the central station. After acknowledgement is received, a “listen in to follow” message 
    is sent to the central station. By responding to this message the central station operator can enter 
    commands that allow him to initiate a 5-minute voice session. The options allow the operator to enter 
    the following modes: 
    • Talk: Allows the operator to speak to individuals at the premises through the system speaker. 
    • VOX (2-way voice): Allows the operator to hold a two-way (speak and listen) conversation with 
    individuals at the premises. 
    • Listen: Allows the operator to listen to any activity at the premises through the system microphone. 
    If a subsequent zone is violated during a voice session, the system will terminate the session and 
    process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs will 
    alternately blink in the Talk and VOX Modes but not during Listen Mode. 
       
    						
    							– 9 – 
    QUICK VIEW OF SYSTEM F
    QUICK VIEW OF SYSTEM FQUICK VIEW OF SYSTEM F QUICK VIEW OF SYSTEM FUNCTIONS
    UNCTIONSUNCTIONS UNCTIONS 
        
     
    NOTE:                         = Boxes represent the entering of your 4-digit user code. 
    SECURITY FUNCTIONS 
    Checking system status: ---------------STATUS  
    To arm in STAY mode:   ----------------                       *
    + STAY  
    To restart exit delay: -------------------STAY  (only if programmed and system armed in Stay mode) 
    To arm in AWAY mode:   ---------------                       *
      +  AWAY  
    To arm with NO DELAY:   -------------                       *
       +  AWAY or  STAY  +   NO DELAY  
    To arm if Quick Arm is active: -----AWAY or  STAY  (hold down for at least 2 seconds) 
    To disarm system and silence alarms:                           +  OFF  
    To bypass a zone(s): ---------------------                         +  BYPASS  + 2-digit zone number(s)  
    To turn Chime mode on or off: -----FUNCTION  +  CHIME  
    *
     Security code is not required if Quick Arm is active. Instead, press and hold down the STAY or  AWAY key. 
     
    MESSAGE CENTER 
    To record a message: -------------------FUNCTION  +   RECORD  
    To stop recording before end of 85 secs:  OFF  
    To play back a message: ---------------FUNCTION  +   PLAY  
    To skip a message:----------------------------  [✻] 
    To delete all messages:--------------------  FUNCTION  +  DELETE (during message replay) 
     
    VOLUME ADJUSTMENT 
    To adjust message playback/announcement volume:  FUNCTION  +   VOLUME + [3]  or [6] 
    To mute system announcements: -FUNCTION  +   VOLUME  +   OFF  
    To restore/unmute announcements:  FUNCTION  +   VOLUME + [3]  or [6] 
     
    SPEAKER PHONE OPERATION 
    To enter speaker phone mode: -----[#] +  AUX  
    To exit speaker phone mode: -------OFF  
    To enable/disable (toggle) ringer: [#] +  VOLUME  +  AUX  
    To return keypad to telephone mode (after clearing an alarm or trouble or disarming the system):  [#] +  AUX  
    To flash (switch between two calls using call waiting): AUX *  
    *To return to first call wait at least two (2) seconds and enter  AUX again.  
    						
    							– 10 – 
    QUICK VIEW OF SYSTEM FUNCTIONS
    QUICK VIEW OF SYSTEM FUNCTIONSQUICK VIEW OF SYSTEM FUNCTIONS QUICK VIEW OF SYSTEM FUNCTIONS 
         
    REMOTE PHONE CONTROL OPERATION  
    To remotely disarm: ---------------------                          +  [1] 
    To remotely arm in AWAY mode: -                          +  [2] 
    To remotely arm in STAY mode: --                          +  [3] 
    To remotely arm in AWAY or STAY mode with NO DELAY:                           +  [2] or [3] + [0] 
    To remotely activate X-10 devices 1-6: ---------  [#] + [4] + device no. 
    To remotely activate X-10 devices 7 & 8: -----                          +  [#] + [4] + device no. 
    To remotely deactivate X-10 devices 1-6: -----  [#] + [7] + device no. 
    To remotely deactivate X-10 devices 7 & 8:                           +  [#] + [7] + device no. 
    To remotely bypass a zone: ----------                          +  [6] + zone no. 
    To remotely activate forced bypass: ------------                          +  [6] + [#]* 
    To remotely check system status: - [*] 
    To hang up: ----------------------------------                          +  [9] 
    *If forced bypass was enabled by your installer.  
    OTHER FUNCTIONS 
    To set the time and date: --------------                          +  FUNCTION  +  [63] 
    To set scheduling: ------------------------                          +  FUNCTION  +  [64] 
    To activate X-10 devices 1-6:  --------FUNCTION  +  LIGHTS ON  + device number  
    To activate X-10 devices 7 & 8: -----                       +FUNCTION +LIGHTS ON + device number 
    To deactivate X-10 devices 1-6:  ----FUNCTION  +  LIGHTS OFF  + device number  
    To deactivate X-10 dev. 7 & 8: -------                       +FUNCTION +LIGHTS OFF + device number 
    To add a user code:   ---------------------                       **
     +  CODE + user no. (02-08)+ user code 
    To delete a user code (except Master Code):                        **
     +  CODE  + user number   (02-08) 
    To turn Test mode on: ------------------                         +  TEST   
    To turn Test mode off: -----------------                        +  OFF   
    To use the defined AUX function:-Press and hold  AUX key 2 seconds (4 beeps) +                          
    To send message to pager:------------Press and hold  AUX key 2 seconds (4 beeps) 
    To program “Follow Me” reminder phone #:                        +FUNCTION + [65] + Enter up to 24 
    digits 
    To delete “Follow Me” reminder phone #:                         +   FUNCTION  +  [65] 
    ** Only the master code can be used to add or delete another user code.   
    						
    All Honeywell manuals Comments (0)