T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 21 Refer to Table 14 for thermostat cross referencing information. Table 14. Thermostat Cross Reference Information. (continued) Model Number DescriptionTRADELINE® Replacement Remarks T8611G Two-stage heat and one-stage cool heat pump thermostat; powered direct from 24 Vac transformer; automatic changeover; system switch—EM HEAT-HEAT-OFF-COOL-AUTO; fan switch—ON-AUTO; O/B or O and B terminals T8611G1004 TRADELINE® thermostat; Honeywell logo.T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1. T8611G1012 Canadian TRADELINE® thermostat; Honeywell logo; degree C.T8611G2002 Configure changeover in Installer Setup 12, °C in 14 and O/B terminal in 29; jumper Y1 to W1. T8611G1020 Heil Quaker; part no. HQ713669HW. T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1. T8611G1038 Trane; part no. THT-0603; ordering no. X13510323-13-7.T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1. T8611G1046 Carrier; part no. HH07AE001. T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal to O in 29; jumper Y1 to W1. T8611G1053 Lennox; part no. 27H3001. T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1. T8611G1095 Trol-A-Temp® by Honeywell thermostat. T8611G2051aO and B terminals are not used. T8611G1103 TRADELINE® thermostat; Honeywell logo; Premier White® color.T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1; taupe color. T8611G1111 Trane; Premier White® color; part no. TAYSTAT501.T8611G2002 Wiring differences (old=new): F=L, B=C; configure changeover in Installer Setup 12 and O/B terminal to O in 29; taupe color. T8611G1145 Canadian TRADELINE® thermostat; Honeywell logo; Premier White® color; degree C.T8611G2002 Configure changeover in Installer Setup 12, °C in 14 and O/B terminal in 29; jumper Y1 to W1; taupe color. T8611G1152 Solitare logo; Premier White® color; Nordyne part no. 9132410.T8611G2002 Configure changeover in Installer Setup 12 and O/B terminal in 29; jumper Y1 to W1; taupe color. T8611G1178 Canadian Carrier; Premier White® color; degree C; part no. HH07AE001C-W.T8611G2002 Configure changeover in Installer Setup 12, °C in 14 and O/B terminal in 29; jumper Y1 to W1; taupe color. T8611R Two-stage heat and one-stage cool heat pump thermostat; powered direct from 24 Vac transformer; system switch—EM HEAT-HEAT-OFF-COOL; fan switch—ON-AUTO; O/B or O and B terminals T8611R1000 TRADELINE® thermostat; Honeywell logo.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1018 York; part no. 025-27655. T8611G2002 Wiring differences (old=new): B=C, H=B, X=L; configure O/B terminal in Installer Setup 29. T8611R1034 Rheem; Honeywell logo; part no. 41-21594-05.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1042 Canadian TRADELINE® thermostat; Honeywell logo; degree C.T8611G2002 Configure O/B terminal in Installer Setup 29 and °C in 14; no P terminal; taupe color. T8611R1059 Coleman; part no. 3600A381. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. a Contact Trol-A-Temp® for thermostat.
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 22 Table 14. Thermostat Cross Reference Information (continued). Model Number DescriptionTRADELINE® Replacement Remarks T8611R1067 ArcoAire; part no. 1506-744. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1075 Comfortmaker. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1083 Amana; part no. D9807605. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1091 Trane. T8611G2002 Wiring differences (old=new): B=C, F=L, X2=E, W1=W2; configure O/B terminal to O in Installer Setup 29; jumper W1 to Y1. T8611R1109 Trane; part no. THT-0602; ordering no. X13510323-12-7.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1117 Trane; part no. ASYSTAT700. T8611G2002 Wiring differences (old=new): B=C, F=L, X2=E, W1=W2; configure O/B terminal to O in Installer Setup 29; jumper W1 to Y1. T8611R1125 Trol-A-Temp® by Honeywell thermostat. T8611G2051aJumper Y1 to W1. T8611R1133 TRADELINE® thermostat; Honeywell logo.T8611G2002 Wiring differences (old=new): B=C, H=B, X=L; configure O/B terminal in Installer Setup 29. T8611R1141 TRADELINE® thermostat; Honeywell logo; Premier White® color.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; taupe color. T8611R1158 TRADELINE® thermostat; Honeywell logo; Premier White® color.T8611G2002 Wiring differences (old=new): B=C, H=B, X=L; configure O/B terminal in Installer Setup 29; taupe color. T8611R1174 Phillilps Energy. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal. T8611R1182 Armstrong; Premier White® color. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; taupe color. T8611R1190 Inter-City Products; Premier White® color; part no. HQ1149375HW.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; taupe color. T8611R1208 Carrier Weathermaker; part no. HH07AX114.T8611G2002 Configure heating cycle rate in Installer Setup no. 4, 5, 7 and O/B terminal in 29; no P terminal. T8611R1216 Carrier Zone Perfect; part no. HH07AX115.T8611G2002 Configure heating cycle rate in Installer Setup no. 4, 5, 7 and O/B terminal in 29; no P terminal. T8611R1224 Consolidated logo; Premier White® color. T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; taupe color. T8611R1240 Millbrook Industries logo; Premier White® color.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; taupe color. CT8611R Two-stage heat and one-stage cool retail heat pump thermostat; powered direct from 24 Vac trans- former; system switch—EM HEAT-HEAT-OFF-COOL; fan switch—ON-AUTO; O and B terminals CT8611R1006 Retail Honeywell logo; clamshell packaging; off-white color.T8611G2002 Configure O/B terminal in Installer Setup 29; no P terminal; TRADELINE® packaging; taupe color. a Contact Trol-A-Temp® for thermostat.
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 23 WIRING DIAGRAM (FIG. 15 AND 16) Fig. 15. Typical hookup of T8611G .Fig. 16. Typical hookup of T8611G with isolated stage-one heating and cooling connections. W2 L1 (HOT) L2 M11311 FAN RELAY Y1 G ETHERMOSTATC HEAT RELAY 1 RW1 COMPRESSOR CONTACTOREM. HT. RELAY TRANSFORMER HEAT RELAY 2 OT OT OUTDOOR SENSOR COOLING OR HEATING CHANGEOVER VALVE O/BX2 LX1 EQUIPMENT MONITOR 2 EQUIPMENT MONITOR 1 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 W2 L1 (HOT) L2 M10823 FAN RELAY Y1 G ETHERMOSTATCRW1 COMPRESSOR CONTACTOREM. HT. RELAY TRANSFORMER HEAT RELAY 2 OT OT OUTDOOR SENSOR COOLING OR HEATING CHANGEOVER VALVE O/BX2 LX1 EQUIPMENT MONITOR 2 EQUIPMENT MONITOR 1 1 2POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY INSTALLED JUMPER. 1 2
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 24 Honeywell Europe S.A. 3 Avenue du Bourget 1140 Brussels BelgiumHoneywell Asia Pacific Inc. Room 3213-3225 Sun Hung Kai Centre No. 30 Harbour Road Wanchai Hong Kong Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Helping You Control Your World ® 68-0165—1 J.H. Rev. 10-97 Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis MN 55408-0524 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com/yourhome