Page 1
T8611G Chronotherm ® IV Deluxe Programmable Heat Pump Thermostat PRODUCT DATA ® U.S. Registered Trademark Copyright © 1997 Honeywell Inc. • All Rights Reserved APPLICATION The T8611G Chronotherm® IV Deluxe Programmable Heat Pump Thermostat provides electronic control of 24 Vac single-zone heat pump systems. FEATURES •Full seven-day program capability; different schedules and temperature setpoints may be selected for everyday to match the homeowner’s flexible schedule. •Copy key makes programming...
Page 2
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone...
Page 3
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 3 Dimensions: See Fig. 1. Mounting Means: The thermostat mounts on a wallplate. The wallplate mounts horizontally on a wall or outlet box with two no. 6 x 32 screws (included). Accessories: C7089B Outdoor Temperature Sensors (69-1020). Universal Versaguard™ Thermostat guards. RECYCLING NOTICE If this control is replacing a control that contains mercury in a sealed tube, do n ot place your old control in the trash. Contact your...
Page 4
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 4 Fig. 2. Typical location of thermostat. Wallplate Installation The thermostat can be mounted horizontally on the wall or on a 2 in. x 4 in. wiring box. Position wallplate horizontally on the wall or on a 2 in. x 4 in. wiring box. 1.Position and level the wallplate (for appearance only). The thermostat will function properly even when not level. 2.Use a pencil to mark the mounting holes. See Fig. 3. WIRES THROUGH WALLWALL...
Page 5
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 5 Standard Terminal DesignationsAlternate Terminal Designations Typical Connection Function Terminal Type B—Heating changeover valve Output 24V powered contact CBa, C, X1, X2 Common Input EKEmergency heat relay Output 24V powered contact GFFan relay Output 24V powered contact LA, A1, C, L, X, Z User defined Light Emitting Diodes (LEDs) Annunciation — ORCooling changeover valve Output 24V powered contact O/B — Cooling or heating...
Page 6
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 6 Mounting Thermostat Wallplate The thermostat mounts on the wallplate after they are installed. 1.Engage tabs at the top of thermostat and wallplate. See Fig. 5. 2.Press lower edge of case to latch. NOTE: To remove the thermostat from the wall, first pull out at the bottom of the thermostat; then remove the top. SETTINGS Using Thermostat Keys The thermostat keys are used to: •set current day and time, •program times and setpoints...
Page 7
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 7 System and Fan Settings The system default setting is Heat and the fan default setting is Auto. Use the System and Fan keys or switches to change the settings. See Fig. 8. The fan settings can be set for each program period individually. The system selection is for all the program periods. System settings control the thermostat operation as follows: Em Heat: Emergency heat output is controlled as Stage 1 heat. Cooling system is...
Page 8
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 8 IMPORTANT Only configurable numbers are shown on the device. Example: If thermostat does not have a system key, Installer Setup Number 12 will not be displayed. Review Table 6 factory settings and mark any desired changes in the Actual Settings column. When Installer Setup is complete, review the settings to confirm that they match the system. Table 6. Thermostat Installer Setup Options. (continued) Installer Setup Number...
Page 9
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 9 Table 6. Thermostat Installer Setup Options (continued). Installer Setup Number (Press Time ▲ key toFactory-SettingOther Choices (Press ▲ or ▼ key to change) Actual Selectchange) Display Description Display DescriptionSetting Deadband 30 3 Heating and cooling setpoints can be set no closer than 3°F (1.5°C)4 thru 10Heating and cooling setpoints can be set no closer than the chosen value: 4—4°F (2°C) 5—5°F (2.5°C)...
Page 10
T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTAT 68-0165—1 10 3.Press Time ▲ ▲ or Time ▼ ▼ until the current time is displayed. NOTE: Tapping the Set Current Day/Time will change the time in one hour increments. Fig. 11. Display of all the segments of the LCD. M10314 Time Set ProgramSystem Fan Run Program Hold TempSet Current Day/TimeWakeLeave Return Sleep Day Time Heat/Cool Settings Daylight TimeCopy AM TueSet Day/Time NOTE: If the current time is Daylight Savings Time, press Daylight...