    							HEPAFILTER
    PREFILTERI
    II
    0III
    HEPAFILTERPREFILTERI
    II
    0III
    The Science of Clean Air®
    Por table True HEPA
    Air Purifiers
    READ AND SAVE THESE INSTRUCTIONS
    INSTALL PRE-FILTER BEFORE USE
    Owner’s Guide
    For LifeTime HEPA™Permanent Filter Model Series
    10590 • 50100 • 50150 • 50200 • 50250 • 50300
    Air Purifiers
    HEPAFILTER
    PREFILTERI
    II
    0
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 1 
    						
    							When using electrical appliances, basic precautions should
    always be followed to reduce the risk of fire, electric shock,
    and injury to persons, including the following:
    1. Read all instructions before operating the air purifier.
    2. Place air purifier where it is not easily knocked over by persons in the household.
    3. Always turn the air purifier to the OFFposition and unplug from the wall outlet when
    not in use.
    4. To disconnect the air purifier, first turn control to the OFFposition, grip the plug and
    pull it from the wall outlet. Never pull by the cord.
    5. Do not use any product with a damaged cord or plug or if product malfunctions, is
    dropped or damaged in any manner. Keep the cord away from heated surfaces.
    6. Do not use air purifier outdoors.
    7. Never use air purifier unless it is fully assembled.
    8. Do not run power cord under carpets, and do not cover with throw rugs. Arrange
    cord such that it will not be tripped over.
    9. Do not use air purifier where combustible gases or vapors are present.
    10. Do not expose the air purifier to rain, or use near water, in a bathroom, laundry area
    or other damp location.
    11. The air purifier must be used in its upright position.
    12. Do not allow foreign objects to enter ventilation or exhaust opening as this may
    cause electric shock or damage to the air purifier. Do not block air outlets or
    intakes.
    13. Locate air purifier near the outlet and avoid using an extension cord.
    14. This appliance has a polarized plug (one blade is wider than the other). To reduce
    the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the
    plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a
    qualified electrician. DO NOTattempt to defeat this safety feature.
    15. A loose fit between the AC outlet (receptacle) and plug may cause overheating and
    a distortion of the plug. Contact a qualified electrician to replace loose or worn
    outlet.
    16. Do not sit, stand or place heavy objects on the air purifier.
    17. Disconnect power supply before servicing.
    WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Air
    Purifier With Any Solid-State Speed Control Device.
    IMPORTANT SAFETY
    INSTRUCTIONS
    READ AND SAVE THESE SAFETY
    INSTRUCTIONS BEFORE USING 
    THIS AIR PURIFIER
    2
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 2 
    						
    							We recommend that you operate your Honeywellair purifier 24 hours a day because
    indoor air can be quickly contaminated by activity in a room, infiltration of outside air,
    and from other sources of contamination. While all the air in a room will not be
    processed by the air purifier, the more air circulated through the filter, the more filtered
    air is returned to the room. Portable air purifiers will be much more effective in rooms
    where all doors and windows are closed.
    Your Honeywellair
    purifier has five basic
    components: the
    powerhead assembly
    (with controls and
    motor), the carbon
    pre-filter, the HEPA
    filter, the base
    assembly, and the
    locking mechanism.
    Base Assembly Carbon Pre-filter
    HEPA Filter
    Locking Mechanism Powerhead Assembly
    True 99.97% HEPA Air Purifier with Germ Reduction
    This air purifier model continually helps clean the air and helps reduce airborne bacteria,
    germs and mold spores by drawing air through the HEPA filter which traps and collects
    these particulates.  In a test lab, the air purifiers were tested for reducing airborne
    pathogens that passed through the filter, and results indicated a bacterial reduction up
    to 100% with a mean reduction of 99.3%.
    For Best Performance
    Germ Reduction
    Construction
    • Select a firm, level and flat location. For proper air flow, locate the unit at least 3 feet
    (1 meter) from any wall or furniture.
    • Due to the large volume of air drawn towards the air purifier, surrounding areas should
    be cleaned and/or vacuumed frequently to prevent dust buildup. If the unit is placed
    on light colored carpeting, a small mat or rug should be used to ease cleaning and
    prevent any permanent staining of carpeting. This is particularly important in homes
    with heavier contamination from smoking or fireplaces.
    •Locate pre-filter in the box and install before initial operation. Refer to
    “Removing/Changing the Filters” section for proper installation.
    Set-up
    3
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 3 
    						
    							• LOCATE PRE-FILTER IN THE BOX AND INSTALL BEFORE INITIAL OPERATION.
    Refer to “Removing/Changing the Filters” section for proper installation.
    • Ensure the air purifier is plugged into a working electrical
    outlet and the Power Knob is turned to the OFF position.
    • Allow the unit to operate for a few seconds at turbo speed,
    then leave the control knob in the turbo position for faster,
    more powerful room cleaning, or move the knob to the 
    sleep setting for quieter operation. 
    It is recommended you run 
    your air purifier 24 hours a
    day to ensure continuous
    cleaning. Portable air
    purifiers are more effective
    in rooms where all doors
    and windows are closed.
    ( SLEEP)
    (DAY)
    ( TURBO)
    O   ( OFF)
    The Intelli-Check™Filter Indicators serve as a convenient guideline for when to clean the
    LifeTime HEPA™ Permanent Filter and when to replace the carbon pre-filter.  Depending
    upon your individual usage (environment and hours used), you may need to clean/replace
    the filters more or less frequently.
    When the 
    HEPA Filter Indicator Light turns on, it’s time to clean your HEPA filter. The
    Intelli-Check™reminder for when to clean the HEPA filter is intended as a guideline only as
    the performance of the filter media is dependent on the concentration of the contaminants
    to which the system is exposed.  If there are sources of large amounts of contaminant
    generation (such as dust from woodworking or heavy smoking) the HEPA filter in your air
    purifier may need to be cleaned more often.  For instructions on how to clean your HEPA
    filter, refer to section “Cleaning the LifeTime HEPA
    ™Permanent Filter” in this manual.
    Operation
    Intelli-Check™Filter Indicator: 
    Models 50150, 50200, 50250, 50300 Series
    The air purifier model 10590, 50100 series is equipped with a Filter Maintenance
    Calendar wheel which serves as a convenient reminder for you to check and replace 
    the pre-filter and clean the HEPA filter based on the air purifier’s hours of use.
    Upon starting your air purifier and upon every pre-filter replacement, roll the pre-filter
    change calendar ahead three months to indicate when the next filter replacement is
    necessary. Upon starting your air purifier and upon every HEPA filter cleaning, roll the
    HEPA filter calendar ahead 6 to 9 months (depending upon use) to indicate when
    cleaning the HEPA filter is necessary.
    Filter Maintenance Calendar: Model 10590, 50100 Series 
    4
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 4 
    						
    							When your Pre-filter Indicator Light turns on, it’s time to replace your pre-filter.It should
    be replaced at least every 3 months.  If there are heavy concentrations of odors, smoke, or
    large particles in the home, you may need to change the carbon pre-filter more often.  For
    instructions on how to replace your pre-filter, refer to section “Removing/Changing the
    Filters” in this manual.
    Note: We do not recommend operating the air purifier without the carbon pre-filter.
    Intelli-Check™Filter Indicator: 
    Models 50150, 50200, 50250, 50300 Series 
    (continued)
    Reset Filter Indicator/Turn Light Off: 
    Models 50150, 50200, 50250, 50300 Series
    HEPAFILTER
    PREFILTERI
    II
    0
    III
    Fig 1To Reset Filter Indicator
    •Once the filter has been checked and cleaned or
    replaced as needed, the filter indicator will need to
    be reset.  
    • With the unit powered on, press and hold the
    appropriate filter indicator button down for
    approximately 10 seconds until the light turns off
    (Fig. 1).  
    CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING
    Do not attempt to wash either the carbon pre-filter or the HEPA filter. They are not
    washable and washing will damage the filters.
    The only two parts requiring any service are the carbon pre-filter and the HEPA filter. No
    tools are needed. To remove or change either filter, disassemble the unit as shown below:
    Step 1: Turn the air purifier off and unplug from the wall outlet.
    Step 2:To open, gently place the air purifier on its side and unscrew the locking 
    mechanism located on the bottom of the unit (Fig. 2).
    Step 3:Remove the base assembly from the air purifier.
    Step 4: Remove the filter assembly (consisting of the HEPA filter and pre-filter) from the 
    internal chamber.
    Fig. 2Fig. 4Fig. 3
    Removing/Changing the Filters
    5
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 5 
    						
    							The LifeTime HEPA™Filter is vacuum-able and should be cleaned regularly for optimum
    performance.
    To Clean the HEPA Filter:
    •DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE HEPA FILTER.
    • Turn the air purifier OFF and unplug from the wall outlet.
    • After removing the filter assembly from the air purifier
    (refer to section “Removing/Changing the Filters” in this
    manual), separate and remove the carbon pre-filter from
    the HEPA filter and place aside (or discard if pre-filter
    needs replacement).
    • To vacuum-clean the filter, hold the filter and run a
    vacuum cleaner with a nozzle or brush attachment along
    the filter to pick-up the dirt and particles (Fig.5). Repeat
    along the entire surface of the HEPA filter.
    •Do not penetrate the HEPA paper pleats with the
    vacuum attachment since tearing or puncturing can occur.
    • Note that the filter may still be discolored even after cleaning it. This is acceptable
    and will not affect performance.  Also, do not be concerned if you still see particles
    attached to the HEPA filter.  The filter performance is still optimal.
    • After vacuuming the filter, wrap the pre-filter around the HEPA filter and place the
    whole assembly back into the internal chamber of the air purifier (see
    “Removing/Changing the Filters”).
    • You now need to reset the Intelli-Check
    ™Filter Indicator.  With the air purifier powered
    on, press and hold the appropriate filter indicator button for approximately 10
    seconds until the light turns off (see Fig. 1).
    • For models 10590 and 50100, roll the HEPA Clean Calendar forward 6 months.
    If the HEPA filter clogs or if you have difficulty cleaning the filter, please visit us at
    www.kaz.com or call us at 1-800-332-1110.
    *Permanent filter life based on ordinary use and care.
    Fig 5
    Cleaning the Lifetime HEPA™Permanent Filter*
    Step 5: Locate the seam of the pre-filter and carefully separate the fastener to remove
    the pre-filter from the HEPA filter (Fig. 3).
    Step 6: Discard used pre-filter if necessary. Clean the HEPA filter if necessary.
    Step 7:Carefully wrap the pre-filter around the HEPA filter so that the ends meet 
    (Fig. 4). Fasten the ends together with the fastener provided. Use Honeywell
    Universal Carbon Pre-filter model #38002.
    Step 8: Place the whole filter assembly into the internal chamber. Close the product by
    replacing the base and tightening the locking mechanism.
    Step 9:Turn the air purifier into an upright position, plug into a wall outlet and it is ready
    for operation.
    Step 10:For models 10590 and 50100, roll forward the Pre-filter Change Calendar 3
    months
    Removing/Changing the Filters (continued)
    6
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 6 
    						
    							We recommend that you clean the air purifier at least once a month and before
    extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier.
    DO NOT USE WATER, WAX POLISH, OR ANY CHEMICAL SOLUTION.
    If you store your Air Purifier for more than 30 days, we recommend: 
    •  Removing both the primary HEPA filter and the carbon pre-filter from the unit.
    •  Discarding the pre-filter.
    •  Wrapping the HEPA filter in an air-tight plastic bag or plastic wrap. Be sure that the
    filter is totally sealed.
    •  To restore the air purifier to service, unwrap the HEPA filter, install a new carbon pre-
    filter, and reinstall both filters in the air purifier. See “Removing/Changing the Filters”
    section for proper installation.
    Cleaning and Storage
    Accessories and Replacement Filters
    To order replacement pre-filters, visit our website at: www.kaz.com
    or call us at 1-800-332-1110.
    Honeywell Universal Carbon Pre-filter (38002): $14.99 USD
    My Air Purifier is starting to make noise and the air output is less. What’s wrong?
    The filters may be dirty. High amounts of contaminates can block the pores in the
    filter and stop the air from moving through it. Clean the HEPA Filter.
    How long should I run my Air Purifier?
    For best results, you should operate your Air Purifier 24 hours a day. This unit will be
    more effective when doors and windows are closed.
    Can I wash the filters?
    No. Washing the filters will destroy them.
    Frequently Asked Questions
    Consumer Relations
    Mail questions or comments to:
    Kaz, Incorporated
    Consumer Relations Dept.
    250 Turnpike Road
    Southborough, MA 01772Call us toll-free at: 1-800-332-1110
    E-mail: [email protected]
    Or visit our website at: www.kaz.com
    Please be sure to specify a model number.
    NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS
    FIRST OR SEE YOUR WARRANTY.  DO NOT RETURN TO THE ORIGINAL PLACE OF
    PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING
    SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR
    PERSONAL INJURY.
    7
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 7 
    						
    							You should first read all instructions
    before attempting to use this product.
    A.This 5 year limited warranty applies to
    repair or replacement of product found
    to be defective in material or
    workmanship. This warranty does not
    apply to damage resulting from
    commercial, abusive, unreasonable
    use or supplemental damage. Defects
    that are the result of normal wear and
    tear will not be considered
    manufacturing defects under this
    warranty.KAZ IS NOT LIABLE FOR
    INCIDENTAL OR CONSEQUENTIAL
    DAMAGES OF ANY NATURE. ANY
    IMPLIED WARRANTY OF
    MERCHANTABILITY OR FITNESS
    FOR A PARTICULAR PURPOSE ON
    THIS PRODUCT IS LIMITED IN
    DURATION TO THE DURATION OF
    THIS WARRANTY.Some jurisdictions
    do not allow the exclusion or limitation
    of incidental or consequential
    damages or limitations on how long an
    implied warranty lasts, so the above
    limitations or exclusions may not apply
    to you. This warranty gives you
    specific legal rights, and you also may
    have other rights which vary from
    jurisdiction to jurisdiction. This
    warranty applies only to the original
    purchaser of this product from the
    original date of purchase.
    B.At its option, Kaz will repair or replace
    this product if it is found to be
    defective in material or workmanship.
    Defective product should be returned
    to the place of purchase in accordance
    with store policy. Thereafter, while
    within the warranty period defective
    product may be returned to Kaz.C.This warranty does not cover the 
    pre-filter or the HEPA filter except for
    material or workmanship defects.
    D.This warranty does not cover damage
    resulting from any unauthorized
    attempts to repair or from any use not
    in accordance with the instruction
    manual.
    E.Return defective product to Kaz,
    Incorporated with a brief description of
    the problem. Include proof of purchase
    and a $10 US/$15.50 CAN check or
    money order for handling, return
    packing and shipping charges. Please
    include your name, address and a
    daytime phone number.  You must
    prepay shipping charges. Send to:
    In U.S.A.:
    Kaz, Incorporated
    Attn: Returns Department
    4755 Southpoint Drive
    Memphis, TN 38118 
    USA
    In Canada:
    Kaz, Incorporated
    Attn: Returns Department
    510 Bronte Street South
    Milton, ON L9T 2X6 
    Canada
    Five Year Limited Warranty
    © 2005 Kaz, Incorporated. All Rights Reserved.
    P/N: N.0054-A
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 8 
    						
    							HEPAFILTERPREFILTERI
    II
    0III
    HEPAFILTERPREFILTERI
    II
    0III
    La science de l’air pur®
    Purificateurs
    d’air portatifs
    LIRE ET CONSERVER CES INSTRUCTIONS
    INSTALLER LE PRÉFILTRE AVANT L’UTILISATION
    Guide d’utilisation
    Pour les filtres permanent LifeTime HEPAMC
    les séries de modèles
    10590 • 50100 • 50150 • 50200 • 50250 • 50300
    de purificateurs d’air
    HEPAFILTER
    PREFILTERI
    II
    0
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 9 
    						
    							L’utilisation d’appareils électriques nécessite des précautions
    élémentaires afin de réduire les risques de bris, d’incendie, de
    choc électrique ou de blessures. Parmi les précautions à observer,
    on compte les suivantes:
    1. Lire toutes les instructions avant d’utiliser le purificateur d’air.
    2. Placer l’appareil là où il ne risque pas d’être renversé par les occupants de la maison.
    3. Toujours régler le purificateur d’air à la position O OF
    FF
    F
    et le débrancher quand il ne sert pas.
    4. Pour débrancher l’appareil, le régler à la position O OF
    FF
    F
    , puis enlever la fiche de la prise de
    courant. Ne jamais tirer sur le cordon d’alimentation.
    5. Éviter d’utiliser tout appareil dont la fiche ou le cordon d’alimentation est endommagé.
    Éviter également d’utiliser l’appareil si celui-ci a montré des signes de mauvais
    fonctionnement, si on l’a laissé tomber ou s’il a été endommagé de quelque façon que ce
    soit. Tenir le cordon d’alimentation loin des surfaces chaudes.
    6. Ne pas utiliser l’appareil en plein air.
    7. Ne pas utiliser l’appareil s’il n’est pas complètement assemblé.
    8. Éviter de faire passer le cordon d’alimentation sous les tapis ou de le recouvrir d’une
    carpette, d’un chemin de couloir, etc. Placer l’appareil à un endroit où l’on ne risque pas
    de trébucher sur le cordon d’alimentation.
    9. Éviter de faire fonctionner l’appareil dans une pièce contenant des gaz ou des vapeurs
    combustibles.
    10. Éviter de laisser l’appareil à la pluie ou de le faire fonctionner à proximité de l’eau, dans
    une salle de bains, une salle de lessive ou dans tout autre endroit humide.
    11. L’appareil doit toujours être en position verticale durant le fonctionnement.
    12. S’assurer qu’aucun corps étranger ne pénètre dans les ouvertures prévues pour la
    ventilation ou l’évacuation, au risque de recevoir une décharge électrique ou
    d’endommager l’appareil. Ne pas bloquer les ouvertures servant à l’admission ou à
    l’évacuation de l’air.
    13. Installer le purificateur d’air à proximité d’une prise de courant et éviter d’utiliser une
    rallonge.
    14. Ce produit est équipé d’une fiche polarisée (fiche dont l’une des lames est plus large que
    l’autre). Afin de réduire les risques de choc électrique, cette fiche ne peut être insérée que
    d’une seule manière dans la prise de courant polarisée. Si la fiche ne s’insère pas
    complètement dans la prise, tourner la fiche. Si la fiche ne s’insère toujours pas dans la
    prise, contacter un électricien. É ÉV
    VI
    IT
    TE
    ER
    R
    de contourner le dispositif de sécurité que
    constitue la fiche polarisée.
    15. Une connexion trop lâche de la fiche dans la prise de courant c.a. peut entraîner une
    surchauffe et une déformation de la fiche. Contacter un électricien pour faire remplacer les
    prises de courant lâches ou usées.
    16. Éviter de s’asseoir sur le purificateur d’air, de se tenir debout dessus ou de déposer des
    objets lourds dessus.
    IMPORTANTES 
    INSTRUCTIONS DE SÉCURITÉ
    LIRE ET CONSERVER CES
    INSTRUCTIONS DE SÉCURITÉ AVANT
    D’UTILISER LE PURIFICATEUR D’AIR
    10
    10590-50000_OM.qxd  4/3/06  2:28 PM  Page 10 
    						
    All Honeywell manuals Comments (0)

    Related Manuals for Honeywell 50150n Manual