    Industrial Wireless Area-Imaging Scanner
    Quick Start Guide
    Crdlss-GRNT-QS Rev A 
    8/12
    Aller à www.honeywellaidc.com pour le français.  
    Vai a www.honeywellaidc.com per litaliano.  
    Gehe zu www.honeywellaidc.com für Deutsch.  
    Ir a www.honeywellaidc.com para español.  
    Para Português, acesse www.honeywellaidc.com.br.  
    Перейти на русскоязычный сайт www.honeywellaidc.com.  
    Pro češtinu jdi na www.honeywellaidc.com.  
    Pre slovenčinu choď na www.honeywellaidc.com  
    日本語 :  www.honeywellaidc.comをご覧ください。
    如要到中国www.honeywellaidc.com(简体)。
    查看繁体版请登陆www.honeywellaidc.com
    한글  www.honeywellaidc.com로 이동합니다. 
    						
    							Note: Refer to your user’s guide for information about cleaning your 
    device.
    For localized language versions of this document, go to www.honeywellaidc.com.
    Getting Started
    Turn off the computer’s power before connecting the base, then 
    power up the computer once the base is fully connected.  When the 
    base is connected and powered up, put the scanner in the base to 
    establish a link.  The green LED on the base flashes to indicate the 
    scanner’s battery is charging.
    Power Supply Assembly (if included)
    Note: The power supply must be ordered separately, if needed. 
    						
    							Connecting the Base
    USB:   
    						
    							Keyboard Wedge:
    RS232 Serial Port: 
    						
    							Reading Techniques
    The view finder projects an aiming 
    beam that should be centered over 
    the bar code, but it can be 
    positioned in any direction for a 
    good read. 
    Hold the scanner over the bar code, 
    pull the trigger, and center the 
    aiming beam on the bar code.
    The aiming beam is smaller when 
    the scanner is closer to the code 
    and larger when it is farther from the 
    code.  Hold the scanner close to 
    smaller bar codes, and farther away 
    from large bar codes to get a proper 
    read.  
    If the bar code is highly reflective (e.g., laminated), you may need to 
    tilt the scanner at an angle so the bar code can be scanned.
    Note: If the scanner beeps 3 times when scanning a bar code, the 
    link has not been established.  If the scanner beeps once, the 
    link has been established.
    Standard Product Defaults
    The following bar code resets all standard product default settings.
    Standard Product Defaults 
    						
    							USB Serial
    Scan the following code to program the scanner to emulate a regular 
    RS232-based COM Port.  If you are using a Microsoft® Windows® 
    PC, you will need to download a driver from the Honeywell website
     (www.honeywellaidc.com).  The driver will use the next available COM Port number.  Apple® Macintosh computers recognize the 
    scanner as a USB CDC class device and automatically use a class 
    driver.
    Note: No extra configuration (e.g., baud rate) is necessary.
    USB PC Keyboard
    Scan the following code to program the scanner for a USB PC 
    Keyboard.  
    USB Serial
    USB PC Keyboard 
    						
    							Keyboard Country
    Scan the Program Keyboard Country bar code below, then scan 
    the numeric bar code(s) from page 2, then the Save bar code to program the keyboard for your country.  As a general rule, the 
    following characters are not supported by the scanner for countries 
    other than the United States:
     @  |  $  #  {  }  [  ]  =  /  ‘    <  >  ~.
    Note: For a complete list of country codes, see the User’s Guide for 
    your product at our website,  www.honeywellaidc.com.
    Country CodeScanCountry CodeScan
    Belgium1Italy5
    Denmark8Norway9
    Finland2Spain10
    France3Switzerland6
    Germany/Austria4USA (Default)0
    Great Britain7
    Program Keyboard Country 
    Save 
    						
    							Locked Link
    If you link a scanner to a base using the Locked Link Mode, other 
    scanners are blocked from being linked if they are inadvertently 
    placed into the base.  If you do place a different scanner into the 
    base, it will charge the scanner, but the scanner will not be linked.
     
    To use a different scanner, you need to unlink the original scanner by 
    scanning the Unlink Scanner bar code.
    Override Locked Scanner
    If you need to replace a broken or lost scanner that is linked to a 
    base, scan the Override Locked Scanner bar code with a new 
    scanner, and place that scanner in the base.  The locked link will be 
    overridden; the broken or lost scanner’s link with the base will be 
    removed, and the new scanner will be linked.
    Unlinking the Scanner
    If the base has a scanner linked to it, that scanner must be unlinked 
    before a new scanner can be linked.  Once the previous scanner is 
    unlinked, it will no longer communicate with the base.  Scan the 
    Unlink Scanner bar code to unlink a scanner.
    Locked Link Mode
    (Single Scanner)
    Override Locked Scanner
    Unlink Scanner 
    						
    							Tr i g g e r
    The following bar codes will allow you to use the scanner in Manual 
    Trigger - Normal Mode (need to press the trigger to read) or 
    Presentation mode (the scanner is activated when it “sees” a bar 
    code).
    Streaming Presentation™
    When in Streaming Presentation mode, the scanner leaves the scan 
    illumination on all the time and continuously searches for bar codes.
    Manual Trigger - Normal
    (Default)
    Presentation Mode
    Streaming Presentation Mode 
    						
    							Suffix
    If you want a carriage return after the bar code, scan the Add CR 
    Suffix bar code.  To add a tab after the bar code, scan the Add Tab 
    Suffix bar code.  Otherwise, scan the Remove Suffix bar code to 
    remove the suffixes.
    Add Code ID Prefix to all Symbologies
    Scan the following bar code if you wish to add a Code ID prefix to all 
    symbologies at once.
    Note: For a complete list of Code IDs, see the User’s Guide for your 
    product at our website,  www.honeywellaidc.com.
    Add CR Suffix
    Remove SuffixAdd Tab Suffix
    Add Code ID Prefix To All Symbologies
    (Temporary) 
    						