Honeywell 1911ier3 Manual
Have a look at the manual Honeywell 1911ier3 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Granit 1911i Industrial Wireless Area-Imaging Scanner Quick Start Guide Crdlss-GRNT-QS Rev A 8/12 Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per litaliano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br. Перейти на русскоязычный сайт www.honeywellaidc.com. Pro češtinu jdi na www.honeywellaidc.com. Pre slovenčinu choď na www.honeywellaidc.com 日本語 : www.honeywellaidc.comをご覧ください。 如要到中国www.honeywellaidc.com(简体)。 查看繁体版请登陆www.honeywellaidc.com 한글 www.honeywellaidc.com로 이동합니다.
Note: Refer to your user’s guide for information about cleaning your device. For localized language versions of this document, go to www.honeywellaidc.com. Getting Started Turn off the computer’s power before connecting the base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery is charging. Power Supply Assembly (if included) Note: The power supply must be ordered separately, if needed.
Reading Techniques The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read. Hold the scanner over the bar code, pull the trigger, and center the aiming beam on the bar code. The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code. Hold the scanner close to smaller bar codes, and farther away from large bar codes to get a proper read. If the bar code is highly reflective (e.g., laminated), you may need to tilt the scanner at an angle so the bar code can be scanned. Note: If the scanner beeps 3 times when scanning a bar code, the link has not been established. If the scanner beeps once, the link has been established. Standard Product Defaults The following bar code resets all standard product default settings. Standard Product Defaults
USB Serial Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver. Note: No extra configuration (e.g., baud rate) is necessary. USB PC Keyboard Scan the following code to program the scanner for a USB PC Keyboard. USB Serial USB PC Keyboard
Keyboard Country Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) from page 2, then the Save bar code to program the keyboard for your country. As a general rule, the following characters are not supported by the scanner for countries other than the United States: @ | $ # { } [ ] = / ‘ < > ~. Note: For a complete list of country codes, see the User’s Guide for your product at our website, www.honeywellaidc.com. Country CodeScanCountry CodeScan Belgium1Italy5 Denmark8Norway9 Finland2Spain10 France3Switzerland6 Germany/Austria4USA (Default)0 Great Britain7 Program Keyboard Country Save
Locked Link If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different scanner into the base, it will charge the scanner, but the scanner will not be linked. To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code. Override Locked Scanner If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked. Unlinking the Scanner If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner bar code to unlink a scanner. Locked Link Mode (Single Scanner) Override Locked Scanner Unlink Scanner
Tr i g g e r The following bar codes will allow you to use the scanner in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a bar code). Streaming Presentation™ When in Streaming Presentation mode, the scanner leaves the scan illumination on all the time and continuously searches for bar codes. Manual Trigger - Normal (Default) Presentation Mode Streaming Presentation Mode
Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes. Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once. Note: For a complete list of Code IDs, see the User’s Guide for your product at our website, www.honeywellaidc.com. Add CR Suffix Remove SuffixAdd Tab Suffix Add Code ID Prefix To All Symbologies (Temporary)