Honeywell 1300g2 Owners Manual
Have a look at the manual Honeywell 1300g2 Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
6 - 35 EAN/JAN 8 EAN/JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On. * On Off Off Off * On
6 - 36 EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN 8 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar codes that have addenda. Default = Not Required. * 5 Digit Addenda 5 Digit Addenda On* 2 Digit Addenda Off 2 Digit Addenda On * 5 Digit Addenda Off * Not Required Required
6 - 37 EAN/JAN 8 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. MSI MSI MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. Off * On On * Off
6 - 38 When Check Character is set to Validate and Transmit, the scanner will only read MSI bar codes printed with the specified type check character, and will transmit this character at the end of the scanned data. When Check Character is set to Validate, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character, but will not transmit the check character with the scanned data. MSI Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Plessey Code Validate Type 10 and Transmit * Validate Type 10, but Don’t Transmit Minimum Message Length Maximum Message Length
6 - 39 Plessey Code Plessey Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > On * Off Minimum Message Length Maximum Message Length
6 - 40 GS1 DataBar Omnidirectional GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > * On Off * On Off
6 - 41 GS1 DataBar Expanded GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. China Post Code * On Off Minimum Message Length Maximum Message Length
6 - 42 China Post Code China Post Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. On * Off Minimum Message Length Maximum Message Length
6 - 43 Korea Post Code Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. On * Off Minimum Message Length Maximum Message Length
6 - 44 Codablock F Codablock F Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. On * Off Minimum Message Length Maximum Message Length