Hitachi Cp X2510n Projector Technical Manual
Have a look at the manual Hitachi Cp X2510n Projector Technical Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 913 Hitachi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&17). Connection 1. Turn off the projector and the computer. 2. Connect the projector's LAN port and the computer's LAN port with a LAN cable. Use the cable that fulfi lls the specifi cation shown in fi gure (Use CAT-5 or greater LAN Cable when LAN ports are used ) 3. Turn the computer on, and after the computer has started up turn the projector on. Command Control via the Network LANLAN LAN cable (CAT-5 or greater)
12 Communicaion Port The following two ports are assigned for the command control.TCP #23 TCP #9715 Configure the following items form a web browser when command control is used. Port Settings Network Control Port1 (Port: 23) Port open Click the [Enable] check box to open [Network Control Port1 (Port: 23)] to use TCP #23. Default setting is “Enable”. Authentication Click the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Disable”. Network Control Port2 (Port: 9715) Port open Click the [Enable] check box to open [Network Control Port2 (Port: 9715)] to use TCP #9715. Default setting is “Enable”. Authentication Click the [Enable] check box for the [Authentication] setting when authentication is required. Default setting is “Enable”. Command Control via the Network When the authentication setting is enabled, the following settings are required. Security Settings Network Control Authentication Password Enter the desired authentication password. This setting will be the same for [Network Control Port1 (Port: 23)] and [Network Control Port2 (Port: 9715)]. Default setting is blank. Re-enter Authentication Password
13 Command Control via the Network (continued) Command control settings [TCP #23] 1. Command format Same as RS-232C communication, refer to RS-232C Communicaton command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added. (1) ACK reply : 06h Refer to RS-232C communication ( &9). (2) NAK reoly : 15h Refer to RS-232C communication ( &9). (3) Error reply : 1Ch + 0000h Refer to RS-232C communication ( &9). (4) Data reply : 1Dh + xxxxh Refer to RS-232C communication ( &9). (5) Authentication error reply : 1Fh + 0400h When authentication error occurred, the projector returns the error code. [TCP #9715] 1. Command format The commands some datum are added to the head and the end of the ones of TCP#9715 are used. Header Data length RS-232C command Check sumConnection ID 0×02 0×0D 13 bytes 1 byte1 byte [Header] 02, Fixed [Data Length] RS-232C commands byte length (0×0D, Fixed) [RS-232C commands] Refer to RS-232C Communication command format ( &9). [Check Sum] This is the value to make zero on the addition of the lower 8 bits from the header to the checksum. [Connection ID] Random value from 0 to 255 (This value is attached to the reply data). NOTE • Operation cannot be guaranteed when the projector receives an undefined command or data. • Provide an interval of at least 40ms between the response code and any other code. • Commands are not accepted during warm-up.
14 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (1) ACK reply : 06h + ××h (××h : connection ID) (2) NAK reoly : 15h + ××h (3) Error reply : 1Ch + 0000h + ××h (4) Data reply : 1Dh + xxxxh + ××h (5) Authentication error reply : 1Fh + 0400h + ××h (6) Projector busy reply: 1Fh + ××××h + ××h When the projector is too busy to receives the command ,the projector returens the error code. In such a case, check the sending code and send the same command again. Automatic Connection Break T h e T C P c o n n e c t i o n w i l l b e a u t o m a t i c a l l y d i s c o n n e c t e d a f t e r t h e r e i s n o communication for 30 seconds after being established. Authentication The projector does not accept commands without authentication success when authentication is enabled. The projector uses a challenge response type authentication with an MD5 (Message Digest 5) algorithm. When the projector is using a LAN, a random 8 bytes will be returned if authentication is enabled. Bind this received 8 bytes and the authentication password and digest this data with the MD5 algorithm and add this in front of the commands to send. Following is a sample if the authentication password is set to “password” and the random 8 bytes are “a572f60c”. 1) Select the projector. 2) Receive the random 8 bytes “a572f60c” from the projector. 3) B i n d t h e r a n d o m 8 b y t e s “ a 5 7 2 f 6 0 c ” a n d t h e a u t h e n t i c a t i o n p a s s w o r d “password” and it becomes “a572f60cpassword”. 4) Digest this bind “a572f60cpassword” with MD5 algorithm. It will be “e3d97429adffa11bce1f7275813d4bde”. 5) Add this “e3d97429adffa11bce1f7275813d4bde” in front of the commands and send the data. Send “e3d97429adffa11bce1f7275813d4bde”+command. 6) When the sending data is correct, the command will be performed and the reply data will be returned. Otherwise, an authentication error will be returned. NOTE • As for the transmission of the second or subsequent commands, the authentication data can be omitted when the same connection. Command Control via the Network (continued)
15 This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by LAN communicaton, an external device that is connected with this projector by RS-232C communication can be controlled from the computer as a network terminal. For details, see the 3.7 Controlling the external device via the projector(using the NETWORK BRIDGE function) - Network Guide. Connection 1. Connect the computer's LAN port and the projector's LAN port with a LAN cable. 2. Connect the projector's CONTROL port and the RS-232C port of the devices that you want to control with a RS-232C cable. 3. Turn the computer on, and after the computer has started up turn the projector on. 4. Set the COMMUNICATION TYPE to NETWORK BRIDGE. (&OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide) Network Bridge Communication Network Bridge Communication LAN CONTROL LAN RS-232C
16 Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION menu. ( &OPTION menu - SERVICE - COMMUNICATION in the User's Manual - Operating Guide ) Item Condition BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) PARITY NONE/ODD/EVEN Start bit 1 bit (fixed) Stop bit 1 bit (fixed) Transmission method HALF-DUPLEX/FULL-DUPLEX NOTE • For connecting the projector to your devices, please read the manual for each devices, and connect them correctly with suitable cables. • Turn off (the power of ) both the projector and other devices and unplug , beore connecting them. • For details of Transmission method, refer to 3.8.4 Transmission method- Network Guide. Network Bridge Communication
17 Names Operation Type Header Command Data CRC Action TypeSetting Code Power SetTurn off BE EF0306 00 2A D3 01 0000 60 00 00 Turn on BE EF0306 00 BA D2 01 0000 60 01 00 Get BE EF0306 00 19 D3 02 0000 60 00 00 [Example return] 00 00 01 00 02 00 [Off] [On] [Cool down] Input Source SetCOMPUTER IN1 BE EF0306 00 FE D2 01 0000 20 00 00 COMPUTER IN2 BE EF0306 00 3E D0 01 0000 20 04 00 COMPONENT BE EF0306 00 AE D1 01 0000 20 05 00 S-VIDEO BE EF0306 00 9E D3 01 0000 20 02 00 VIDEO BE EF0306 00 6E D3 01 0000 20 01 00 Get BE EF0306 00 CD D2 02 0000 20 00 00 Error Status GetBE EF0306 00 D9 D8 02 0020 60 00 00 [Example return] 00 00 01 00 02 00 03 00 [Normal] [Cover error] [Fan error] [Lamp error] 04 00 05 00 07 00 08 00 [Temp error] [Air flow error] [Cold error] [Filter error] MAGNIFY GetBE EF0306 00 7C D2 02 0007 30 00 00 Increment BE EF0306 00 1A D2 04 0007 30 00 00 Decrement BE EF0306 00 CB D3 05 0007 30 00 00 FREEZE SetNORMAL BE EF0306 00 83 D2 01 0002 30 00 00 FREEZE BE EF0306 00 13 D3 01 0002 30 01 00 Get BE EF0306 00 B0 D2 02 0002 30 00 00 PICTURE MODE SetNORMAL BE EF0306 00 23 F6 01 00BA 30 00 00 CINEMA BE EF0306 00 B3 F7 01 00BA 30 01 00 DYNAMIC BE EF0306 00 E3 F4 01 00BA 30 04 00 BOARD(BLACK) BE EF0306 00 E3 EF 01 00BA 30 20 00 BOARD(GREEN) BE EF0306 00 73 EE 01 00BA 30 21 00 WHITEBOARD BE EF0306 00 83 EE 01 00BA 30 22 00 DAYTIME BE EF0306 00 E3 C7 01 00BA 30 40 00 Get BE EF0306 00 10 F6 02 00BA 30 00 00 [Example return] 00 00 01 00 04 00 10 00 [Normal] [Cinema] [Dynamic] [Custom] 20 00 21 00 22 00 40 00 [BOARD(BLACK)] [BOARD(GREEN)] [WHITEBOARD] [DAY TIME] BRIGHTNESS GetBE EF0306 00 89 D2 02 0003 20 00 00 Increment BE EF0306 00 EF D2 04 0003 20 00 00 Decrement BE EF0306 00 3E D3 05 0003 20 00 00 BRIGHTNESS Reset ExecuteBE EF0306 00 58 D3 06 0000 70 00 00 CONTRAST GetBE EF0306 00 FD D3 02 0004 20 00 00 Increment BE EF0306 00 9B D3 04 0004 20 00 00 Decrement BE EF0306 00 4A D2 05 0004 20 00 00 CONTRAST Reset ExecuteBE EF0306 00 A4 D2 06 0001 70 00 00 (continued on next page) RS-232C Communication / Network command table RS-232C Communication / Network command table
18 Names Operation Type Header Command Data CRC Action TypeSetting Code GAMMA Set1 DEFAULT BE EF0306 00 07 E9 01 00A1 30 20 00 1 CUSTOM BE EF0306 00 07 FD 01 00A1 30 10 00 2 DEFAULT BE EF0306 00 97 E8 01 00A1 30 21 00 2 CUSTOM BE EF0306 00 97 FC 01 00A1 30 11 00 3 DEFAULT BE EF0306 00 67 E8 01 00A1 30 22 00 3 CUSTOM BE EF0306 00 67 FC 01 00A1 30 12 00 4 DEFAULT BE EF0306 00 F7 E9 01 00A1 30 23 00 4 CUSTOM BE EF0306 00 F7 FD 01 00A1 30 13 00 5 DEFAULT BE EF0306 00 C7 EB 01 00A1 30 24 00 5 CUSTOM BE EF0306 00 C7 FF 01 00A1 30 14 00 6 DEFAULT BE EF0306 00 57 EA 01 00A1 30 25 00 6 CUSTOM BE EF0306 00 57 FE 01 00A1 30 15 00 Get BE EF0306 00 F4 F0 02 00A1 30 00 00 User Gamma Pattern SetOff BE EF0306 00 FB FA 01 0080 30 00 00 9 steps gray scale BE EF0306 00 6B FB 01 0080 30 01 00 15 steps gray scale BE EF0306 00 9B FB 01 0080 30 02 00 Ramp BE EF0306 00 0B FA 01 0080 30 03 00 Get BE EF0306 00 C8 FA 02 0080 30 00 00 User Gamma Point 1 GetBE EF0306 00 08 FE 02 0090 30 00 00 Increment BE EF0306 00 6E FE 04 0090 30 00 00 Decrement BE EF0306 00 BF FF 05 0090 30 00 00 User Gamma Point 1 ResetExecute BE EF0306 00 58 C2 06 0050 70 00 00 User Gamma Point 2 GetBE EF0306 00 F4 FF 02 0091 30 00 00 Increment BE EF0306 00 92 FF 04 0091 30 00 00 Decrement BE EF0306 00 43 FE 05 0091 30 00 00 User Gamma Point 2 ResetExecute BE EF0306 00 A4 C3 06 0051 70 00 00 User Gamma Point 3 GetBE EF0306 00 B0 FF 02 0092 30 00 00 Increment BE EF0306 00 D6 FF 04 0092 30 00 00 Decrement BE EF0306 00 07 FE 05 0092 30 00 00 User Gamma Point 3 ResetExecute BE EF0306 00 E0 C3 06 0052 70 00 00 User Gamma Point 4 GetBE EF0306 00 4C FE 02 0093 30 00 00 Increment BE EF0306 00 2A FE 04 0093 30 00 00 Decrement BE EF0306 00 FB FF 05 0093 30 00 00 User Gamma Point 4 ResetExecute BE EF0306 00 1C C2 06 0053 70 00 00 User Gamma Point 5 GetBE EF0306 00 38 FF 02 0094 30 00 00 Increment BE EF0306 00 5E FF 04 0094 30 00 00 Decrement BE EF0306 00 8F FE 05 0094 30 00 00 User Gamma Point 5 ResetExecute BE EF0306 00 68 C3 06 0054 70 00 00 User Gamma Point 6 GetBE EF0306 00 C4 FE 02 0095 30 00 00 Increment BE EF0306 00 A2 FE 04 0095 30 00 00 Decrement BE EF0306 00 73 FF 05 0095 30 00 00 User Gamma Point 6 ResetExecute BE EF0306 00 94 C2 06 0055 70 00 00 User Gamma Point 7 GetBE EF0306 00 80 FE 02 0096 30 00 00 Increment BE EF0306 00 E6 FE 04 0096 30 00 00 Decrement BE EF0306 00 37 FF 05 0096 30 00 00 User Gamma Point 7 ResetExecute BE EF0306 00 D0 C2 06 0056 70 00 00 RS-232C Communication / Network command table (continued) (continued on next page)
19 Names Operation Type Header Command Data CRC Action TypeSetting Code User Gamma Point 8 Get BE EF0306 00 7C FF 02 0097 30 00 00 Increment BE EF0306 00 1A FF 04 0097 30 00 00 Decrement BE EF0306 00 CB FE 05 0097 30 00 00 User Gamma Point 8 ResetExecute BE EF0306 00 2C C3 06 0057 70 00 00 COLOR TEMP Set1 HIGH BE EF0306 00 0B F5 01 00B0 30 03 00 1 CUSTOM BE EF0306 00 CB F8 01 00B0 30 13 00 2 MID BE EF0306 00 9B F4 01 00B0 30 02 00 2 CUSTOM BE EF0306 00 5B F9 01 00B0 30 12 00 3 LOW BE EF0306 00 6B F4 01 00B0 30 01 00 3 CUSTOM BE EF0306 00 AB F9 01 00B0 30 11 00 4 Hi-BRIGHT-1 BE EF0306 00 3B F2 01 00B0 30 08 00 4 CUSTOM BE EF0306 00 FB FF 01 00B0 30 18 00 5 Hi-BRIGHT-2 BE EF0306 00 AB F3 01 00B0 30 09 00 5 CUSTOM BE EF0306 00 6B FE 01 00B0 30 19 00 6 Hi-BRIGHT-3 BE EF0306 00 5B F3 01 00B0 30 0A 00 6 CUSTOM BE EF0306 00 9B FE 01 00B0 30 1A 00 Get BE EF0306 00 C8 F5 02 00B0 30 00 00 COLOR TEMP GAIN R GetBE EF0306 00 34 F4 02 00B1 30 00 00 Increment BE EF0306 00 52 F4 04 00B1 30 00 00 Decrement BE EF0306 00 83 F5 05 00B1 30 00 00 COLOR TEMP GAIN R Reset Execute BE EF0306 00 10 C6 06 0046 70 00 00 COLOR TEMP GAIN G GetBE EF0306 00 70 F4 02 00B2 30 00 00 Increment BE EF0306 00 16 F4 04 00B2 30 00 00 Decrement BE EF0306 00 C7 F5 05 00B2 30 00 00 COLOR TEMP GAIN G Reset Execute BE EF0306 00 EC C7 06 0047 70 00 00 COLOR TEMP GAIN B GetBE EF0306 00 8C F5 02 00B3 30 00 00 Increment BE EF0306 00 EA F5 04 00B3 30 00 00 Decrement BE EF0306 00 3B F4 05 00B3 30 00 00 COLOR TEMP GAIN B Reset Execute BE EF0306 00 F8 C4 06 0048 70 00 00 COLOR TEMP OFFSET R Get BE EF0306 00 04 F5 02 00B5 30 00 00 Increment BE EF0306 00 62 F5 04 00B5 30 00 00 Decrement BE EF0306 00 B3 F4 05 00B5 30 00 00 COLOR TEMP OFFSET R Reset Execute BE EF0306 00 40 C5 06 004A 70 00 00 COLOR TEMP OFFSET G Get BE EF0306 00 40 F5 02 00B6 30 00 00 Increment BE EF0306 00 26 F5 04 00B6 30 00 00 Decrement BE EF0306 00 F7 F4 05 00B6 30 00 00 COLOR TEMP OFFSET G Reset Execute BE EF0306 00 BC C4 06 004B 70 00 00 COLOR TEMP OFFSET B Get BE EF0306 00 BC F4 02 00B7 30 00 00 Increment BE EF0306 00 DA F4 04 00B7 30 00 00 Decrement BE EF0306 00 0B F5 05 00B7 30 00 00 COLOR TEMP OFFSET B Reset Execute BE EF0306 00 C8 C5 06 004C 70 00 00 (continued on next page) RS-232C Communication / Network command table (continued)
20 Names Operation Type Header Command Data CRC Action TypeSetting Code COLOR GetBE EF0306 00 B5 72 02 0002 22 00 00 Increment BE EF0306 00 D3 72 04 0002 22 00 00 Decrement BE EF0306 00 02 7305 0002 22 00 00 COLOR Reset ExecuteBE EF0306 00 80 D0 06 000A 70 00 00 TINT GetBE EF0306 00 49 7302 0003 22 00 00 Increment BE EF0306 00 2F 73 04 0003 22 00 00 Decrement BE EF0306 00 FE 72 05 0003 22 00 00 TINT Reset ExecuteBE EF0306 00 7C D1 06 000B 70 00 00 SHARPNESS GetBE EF0306 00 F1 72 02 0001 22 00 00 Increment BE EF0306 00 97 7204 0001 22 00 00 Decrement BE EF0306 00 46 7305 0001 22 00 00 SHARPNESS Reset ExecuteBE EF0306 00 C4 D0 06 0009 70 00 00 ACTIVE IRIS * SetOFF BE EF0306 00 0B 22 01 0004 33 00 00 THEATER BE EF0306 00 CB 2F 01 0004 33 10 00 PRESENTATION BE EF0306 00 5B 2E 01 0004 33 11 00 Get BE EF0306 00 38 2202 0004 33 00 00 MY MEMORY Load Set1BE EF0306 00 0E D7 01 0014 20 00 00 2 BE EF0306 00 9E D6 01 0014 20 01 00 3 BE EF0306 00 6E D6 01 0014 20 02 00 4 BE EF0306 00 FE D7 01 0014 20 03 00 MY MEMORY Save Set1BE EF0306 00 F2 D6 01 0015 20 00 00 2 BE EF0306 00 62 D7 01 0015 20 01 00 3 BE EF0306 00 92 D7 01 0015 20 02 00 4 BE EF0306 00 02 D6 01 0015 20 03 00 ASPECT Set4:3 BE EF0306 00 9E D0 01 0008 20 00 00 16:9 BE EF0306 00 0E D1 01 0008 20 01 00 14:9 BE EF0306 00 CE D6 01 0008 20 09 00 16:10 BE EF0306 00 3E D6 01 0008 20 0A 00 NORMAL BE EF0306 00 5E DD 01 0008 20 10 00 Get BE EF0306 00 AD D0 02 0008 20 00 00 OVER SCAN GetBE EF0306 00 91 7002 0009 22 00 00 Increment BE EF0306 00 F7 70 04 0009 22 00 00 Decrement BE EF0306 00 26 7105 0009 22 00 00 OVER SCAN Reset ExecuteBE EF0306 00 EC D9 06 0027 70 00 00 V POSITION GetBE EF0306 00 0D 83 02 0000 21 00 00 Increment BE EF0306 00 6B 83 04 0000 21 00 00 Decrement BE EF0306 00 BA 82 05 0000 21 00 00 V POSITION Reset ExecuteBE EF0306 00 E0 D2 06 0002 70 00 00 H POSITION GetBE EF0306 00 F1 82 02 0001 21 00 00 Increment BE EF0306 00 97 8204 0001 21 00 00 Decrement BE EF0306 00 46 8305 0001 21 00 00 H POSITION Reset ExecuteBE EF0306 00 1C D3 06 0003 70 00 00 H PHASE GetBE EF0306 00 49 8302 0003 21 00 00 Increment BE EF0306 00 2F 83 04 0003 21 00 00 Decrement BE EF0306 00 FE 82 05 0003 21 00 00 * ACTIVE IRIS is available only for CP-X2510N and CP-X3010N. (continued on next page) RS-232C Communication / Network command table (continued)