Home > Haier > Fridge freezer > Haier Hrf 369aa Service Manual

Haier Hrf 369aa Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Haier Hrf 369aa Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 68 Haier manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							10  There are so many joints and sealed surfaces in a 
    refrigerator ,accordingly ,quite a lot potential leak points do exist in the 
    system .In troubleshooting ,pay attention to those parts that are liable to 
    leak ,check main connection points for oil seepage and tubing for cracks .If 
    there is no severer leak point ,charge the system with nitrogen and detect 
    leak points with the commonly adopted method ,repair 
    them ,evacuate ,charge the system with refrigerant ,and then turn on the 
    refrigerator to make a test run . 
    2) Too much refrigerant charged into the system 
    Analysis of Trouble 
    a) In case the amount of refrigerant charged into the system exceeds 
    its nominal capacity ,the superfluous refrigerant will of course take some 
    space of the evaporator ,thus reducing its heat-dissipation area and hence 
    the refrigerating efficiency of the system .The abnormal phenomena 
    caused by this reason are as follows :the gas suction and exhaust 
    pressures are generally higher than their respective normal values ,the 
    temperature of its condenser is higher and the electric current of the 
    compressor rises ,loose frost forms on the evaporator ,the refrigerator 
    temperature drops slowly ,and frost appears on the gas return tube . 
    b) In case excessive refrigerant has been charged ,the liquid 
    refrigerant that cannot evaporates in the evaporator will return to the 
    compressor ,and thus a phenomenon of “liquid striking” will occur .The 
    liquid refrigerant evaporates and effervesces as soon as it flows into the 
    refrigerating oil at the bottom of compressor .If the condition is 
    severe ,foams will fill all over inside the compressor housing and be sucked 
    by the piston ,causing damage to the components of compressor . 
    Remedy 
    According to the operating procedures ,it is mandatory to turn the 
    machine off ,and several minutes later ,open the refrigerant charging tube 
    and let the refrigerant escape from it ,replace the dry filter ,recharge 
    refrigerant after evacuating ,and then seal the charging port . 
    3) There is air left in the refrigerating system 
    Analysis of Trouble 
    Residual air in the refrigerating system will reduce its refrigerating 
    efficiency .The prominent phenomena are the increase in its gas suction 
    and exhaust pressures (however ,the gas exhaust pressure will not exceed 
    its rated value ),obvious increase in temperature in the segment from the 
    compressor outlet to the condenser inlet .Because there is air in the 
    system ,both the gas exhaust pressure and temperature will rise ,and 
    moreover ,the gas flowing sound is intermittent and obviously louder . 
    Remedy 
    After shut down for several minutes ,open the tubing ,evacuate it and 
    then recharge the system with refrigerant . 
    4) Low efficiency of compressor Maintenance Service and Trouble Shooting  
    						
    							11  Analysis of Trouble 
    Low efficiency of a refrigerating compressor refers to the actual 
    reduction of gas discharge capacity ,and hence the corresponding 
    reduction of refrigerating capacity ,under the condition that the refrigerant in 
    the system is unchanged .This phenomenon occurs mostly when the 
    compressor has been used for quite a long time ,its moving parts have 
    worn to a considerable degree ,fit clearance between various parts have 
    increased and sealing property of its gas valve has deteriorated ,resulting 
    in an decrease in its actual gas discharge capacity . 
    Methods of Judgment 
    Measure the high and low pressures with pressure gauges to see 
    whether they are normal .If an abnormal sound comes from the compressor 
    or the temperature of its causing is too high ,Cut the discharge port open 
    and operate the compressor ,feel it if there is pressure at the discharge port 
    with your finger (For a normal compressor ,its discharge port is difficult to 
    be blocked with your finger if you just apply a little effort). 
    5) Too thick frost layer formed on evaporator 
    Analysis of Trouble 
    If a direct cooling refrigerator is to be used for a prolonged period of 
    time ,be sure to defrost its evaporator regularly ;if you fail to do so ,the frost 
    layer on the evaporator tubing will become thicker and thicker .Heat 
    conduction will be severely affected when the whole tubing is wrapped with 
    a transparent ice layer ,and finally the temperature in the refrigerator 
    cannot drop down to the prescribed range . 
    Remedy 
    Turn the refrigerator off ,and make preparations for defrosting ,open the 
    refrigerator door to let the air come in ,or use a fan to speed up air flowing 
    so as to shorten the time needed for defrosting .Never strike the frost layer 
    with any iron tools or wood stick in order to avoid damage to the evaporator 
    tubing . 
    6) Refrigerating oil left in evaporator tubing  
    Analysis of Trouble 
    During the process of refrigerating cycles ,a little refrigerating oil may 
    remain in the evaporator tubing ,and after a longer time of operation ,if 
    there is considerable refrigerating oil left in the evaporator ,the heat 
    conduction effect will be severely affected ,thus causing a poor refrigerating 
    effect . 
    Remedy 
    It is quite difficult to determine whether this trouble is caused by the 
    refrigerating oil left in the evaporator tubing ,because this kind of 
    phenomenon and other several trouble are tends to be confused .Generally 
    speaking ,you can make a judgment based on the frost formed on the 
    evaporator .If the frost does not cover the evaporator , and moreover ,it is 
    loosely formed ,you can make a judgment that the deterioration of Maintenance Service and Trouble Shooting  
    						
    							12  refrigerating effect is due to the accumulation of refrigerating oil left in the 
    evaporator tubing in case no other troubles have been found . To clear off 
    refrigerating oil left in the evaporator ,dismantle the evaporator ,purge it 
    thoroughly and then dry it .In case it is difficult to dismantle it ,charge 
    refrigerant from the evaporator inlet to wash it several times ,then purge 
    and dry it with nitrogen . 
    7) Flowing obstructed in refrigerating system 
    Analysis of Trouble 
    Because the refrigerating system was originally not purged 
    thoroughly ,some of the filter screen meshes have been clogged by dirt 
    accumulated in the filter after using it for a certain time of period ,thus 
    resulting in a decrease in flow rate ,and hence a poorer refrigerating effect . 
    The abnormal phenomena caused by this kind of slight clogging in the 
    system are as follows: the gas discharge pressure is lower ,the 
    temperature of discharged gas drops down ,the position clogged has a 
    temperature lower than that in normal conditions ,and for a severe 
    clogging ,even dew condensation as frosting may appear . 
    Remedy 
    Purge the tubing ,and after replacing the dry filter with a new one or 
    clearing it thoroughly ,recharge the system with refrigerant and seal the 
    charging port . 
    B. No Refrigerating 
    The phenomenon that the compressor runs normally ,but no frost (or 
    only a little frost ) appears on the evaporator ,and the refrigerator 
    temperature does not drop down is called “no refrigerating”. There are 
    many causes for this trouble and it is relatively complicated , too . In 
    servicing ,special attention to finding direct causes for this 
    phenomenon .Three main potential causes for this trouble are analyzed 
    below : 
    1) All refrigerant in the system has leaked out 
    Analysis of Trouble 
    Leak points in the refrigerating system have not been found and 
    repaired timely ,thus resulting in the total escape of refrigerant .There are 
    two kinds of leakage :I) slow leakage for instance ,when we want to use a 
    refrigerator that has been put out of quite a long time ,we find the leakage 
    of refrigerant ,or in the course of its operation ,we have found that the 
    refrigerator is gradually becoming not so cold and finally no refrigerating 
    cab be achieved ; ii) fast leakage in that  case ,all the refrigerant will 
    escape swiftly due to abrupt rupture of system tubing . 
    Symptoms of total leakage of refrigerant are mainly as follows : the 
    compressor can be started easily (if there is no damage to the compressor 
    parts) and its operating current becomes low ,its gas suction pressure is 
    high and discharge pressure is lower ,the gas discharge tube feels rather 
    cold ,no sound of gas eruption from the liquid in the evaporator can be Maintenance Service and Trouble Shooting  
    						
    							13  heard ,and no will gush out of the process tube if you cut it open after 
    shutdown . 
    Remedy 
    Check the whole machine , particularly those locations which are liable 
    to leak .After leak points have been found ,repair them or replace them with 
    new parts according to specific circumstances ,then evacuate the system 
    and finally charge refrigerant. 
    2) Refrigerating system has been clogged 
    a) Clogged with Ice 
    Analysis of Trouble 
    The dryness treatment for the major parts in the refrigerating system 
    has been performed improperly, the effect of air purging for the whole 
    system is not good ,or the water content in the refrigerant is out of 
    standard ,all these will cause the expansion valve to be clogged with 
    ice .The symptom for this trouble are as follows :the refrigerator sometimes 
    can refrigerate and sometimes cannot :the refrigerator compartment works 
    normally at the beginning ,but after working for a certain period of 
    time ,frosting begins at the clogged position ,evaporation temperature 
    reaches below 0℃, water will accumulate at the narrow part of the capillary 
    and clog it gradually ,then frost begins to melt at the evaporator ,no gas 
    flowing sound can be heard ,and the gas suction pressure assumes a state 
    of vacuum .Note that these phenomena will appear intermittently ; 
    sometimes ,the refrigerator works well ,and sometimes not well .In order to 
    determine whether it is clogged with ice ,heat the suspicious points with hot 
    water to make ice melt ,and after a while if a gas flowing sound resulting 
    from an abrupt gush is heard and the gas suction pressure rises as well ,it 
    can be confirmed that the trouble is caused by ice clogging . 
    Remedy 
    If there is too much moisture in the refrigerating system, it is advisable 
    to release the refrigerant, purge the tubing with nitrogen, and then charge 
    the system with the filtered refrigerant. However, the commonly adopted 
    method is to connect a filter with moisture absorbers (such as silica-gel, 
    anhydrous calcium chloride) to the refrigerating system so as to filter out 
    the moisture from the system, then replace the filter, evacuate it again and 
    finally charge the system with refrigerant.  
    b) Clogged with dirt in capillary  
    Analysis of Trouble 
    The capillary inlet is a place where coarse-grained dirt or refrigerant oil 
    in the system will tend to settle down and clog it. In case considerable dirt 
    accumulates there, the whole filter screen may be blocked totally, making 
    the refrigerant unable to go through. Clogging with dirt exhibits the same 
    symptoms as that with ice, namely, higher gas suction pressure, lower 
    temperature of discharged gas, and no gas flowing sound from the 
    evaporator. The difference between the both is as follows: if the clogging is Maintenance Service and Trouble Shooting  
    						
    							14  caused by dirt , tapping the suspicious clogged point (generally in the 
    capillary or the connection joint of the filter) may cause the refrigerant to 
    flow through partially, resulting in some corresponding change, whereas in 
    that case if you heat it with a hot towel, no reaction will happen, no flowing 
    sound can be heard, moreover, there is no periodic change. After rejecting 
    the possibility of ice clogging, it can be generally considered as the 
    clogging due to dirt . 
    Remedy  
    Dismantle the system, remove the dry filter from it, purge the tubing with 
    nitrogen, install a new filter, then evacuate it and finally charge it with 
    refrigerant.  
    C) Clogging in filter 
    Analysis of Trouble 
    Total clogging of a filter is rarely to occur. This trouble is mostly caused 
    by the paste-like matter formed from the substances filled into the system 
    or other dust after the refrigerator has been used for a longer time, or by 
    the dirt accumulated gradually inside the filter. Sometimes, tapping the filter 
    nay cause a passage for flowing, Touching it with your hand, you will feel 
    that it is cooler compared with its temperature in the normal state. 
    Remedy 
    The same as described in the capillary clogging with dirt. 
    3) Troubles of Compressor 
    a) Breakage of gas suction and discharge valve blocks 
    Analysis of Trouble  
    The compressor works by means of the opening and closing of gas 
    suction valve and discharge valve to suck and discharge the refrigerant. If 
    the valve block is broken, the refrigerant can not be discharged, and hence 
    no refrigerating can be achieved. 
    Method for making judgement  
    It is quite difficult to differentiate this trouble from others because they 
    often have similar symptoms. In repairing, firstly, hear attentively if there is 
    some abnormal sound coming from the compressor (sometimes , the 
    broken pieces of valve block may strike against the cylinder), and feel the 
    compressor casing with your hand to ascertain whether it is too hot, this is 
    also helpful to the troubleshooting; secondly, measure the pressures at the 
    high and low pressure ports of the compressor with pressure gauges, if the 
    gas suction valve block is broken, the suction pressure gauge pointer will 
    swing violently and the suction pressure is very high, whereas when the 
    gas discharge valve block is broken , the discharge pressure gauge pointer 
    will swing drastically and the discharge pressure is very high. In the both 
    cases, stop the compressor at once, and if technique is available, open the 
    cylinder cover and check up the valve block, repair it, or replace it with a 
    new one,  
    C. Sudden stop of Compressor during Its Running  Maintenance Service and Trouble Shooting  
    						
    							15  The cause of sudden stop of a compressor during its running is mostly 
    that the gas suction pressure and/or discharge pressure exceed their 
    respective prescribed ranges, thus making a pressure-operated protective 
    relay shut off the power to the compressor and stop it. In the following we 
    discuss mainly the reasons for causing excessively high gas discharge 
    pressure and low suction pressure. 
    1) Stoppage due to excessively high gas discharge pressure 
    A) Too much refrigerant charged into the system  
    Analysis of Trouble  
    The phenomenon, such as loose frosting and poor refrigerating effect, 
    may occur if excessive refrigerant has been charged into the system. 
    Superfluous refrigerant will occupy a certain space of the evaporator, thus 
    reduce its heat dissipating area, and the phenomenon of “liquid striking” 
    may occur, too. Meanwhile, dew or frost condensation may occur on the 
    gas return tube, and the gas discharge pressure will obviously rise, when it 
    reaches the threshold value, the protective relay will actuate and shut off 
    the power supply to the compressor. 
    Remedy 
    Open the tubing, re-evacuate and then charge the system with a proper 
    quantity of refrigerant. 
    b) Air left in the system  
    Analysis of Trouble  
    The residual air in the system will circulate together with the refrigerant 
    in the system. The major symptoms caused by this residual air is higher 
    gas discharge pressure, higher discharged gas temperature (the gas 
    discharge tubing is considerably hot when you feel it with your hand), and 
    poorer refrigerating effect. Furthermore, the gas discharge pressure will 
    exceed its normal value when the compressor has run for a period not too 
    long, thus making the protective relay actuate and bring to a stoppage. 
    Remedy 
    Check up how the air has been left in the refrigerating system. 
    Generally, there are two possibilities: one is that the air has been sucked 
    into the system when repairing due to carelessness, or it has not been 
    purged out totally when evacuating the system; the other is that there are 
    leak points at the low pressure end of the refrigerating system. Leak points 
    appear mostly in those low temperature parts or assemblies, because the 
    evaporation temperature is lower for such low temperature devices, 
    especially at the low pressure end, it is easier for the air goes into the 
    system. Once it has been ascertained that air does exist in the system, you 
    have to open the tubing, re-evacuate it and then charge it with refrigerant. 
    2) Stoppage due to electric troubles  
    a) Thermostat  is out of control 
    Analysis of Trouble  
    In case the thermostat does not work in its good order or its Maintenance Service and Trouble Shooting Maintenance Service and Trouble Shooting  
    						
    							16  temperature sensor has not been installed properly, frequent stoppage is 
    also likely to occur. 
    Remedy 
    Try to adjust the temperature sensor’s position until the compressor can 
    be started and stopped normally. If this cannot be achieved, and the 
    stoppage still occurs repeatedly, it is most likely that the mechanical parts 
    or contacts are out of order, disassemble the thermostat, make a thorough 
    checkup and repair it. 
    b) Overload of electric motor  
    Analysis of Trouble  
    Probably, too many things have been put into the refrigerator, and 
    hence the thermal load exceeds its refrigerating capacity ; or in case the 
    power supply voltage drops considerably, the current flowing through the 
    motor will increase drastically making the thermal protector actuate and the 
    fuse blown , and hence the motor stops running. If the motor is still running 
    continuously in such a case , its windings will be burned out . 
    Remedy 
    Reduce the thermal load, pay attention to the variation in voltage of the 
    power supply. 
    c) Abnormal thermal protection 
    Analysis of Trouble  
    The compressor current is within its normal range, but the thermal 
    protector actuates repeatedly. 
    Remedy 
    Replace the thermal protector with a new one. 
    3) Sudden stoppage due to other causes  
    Normal Stoppage 
    Start and stop of the compressor is generally controlled by a thermostat . 
    When the temperature in the refrigerator reaches its desired value, the 
    thermostat will shut down the compressor automatically. Never take this 
    normal operation as a trouble, care should be taken to differentiate it from 
    other real troubles in servicing. 
    D. Compressor won t start 
    In case the compressor cannot be started, you must find out the origins 
    of this trouble through checkup step by step, because probably there are 
    many causes, including those electrical and mechanical. 
    1) Inspect the power supply to see whether it is connected to the 
    compressor circuit. 
    Analysis of Trouble 
    In case the compressor cannot be started, this will generally exhibit in 
    the power supply circuit, for instance, power failure, poor contact of switch, 
    and blown fuse. Make a comprehensive analysis of these phenomena, fine 
    out its real cause and take correct measures to remove this trouble. 
    Remedy Maintenance Service and Trouble Shooting  
    						
    							17  a) Check the input power circuit to see whether where is voltage of the 
    power supply,  namely, the circuit which is connected to the knife switch. 
    This can be determined with an avometer or a test pencil. If a blown fuse is 
    found, ascertain and remove its cause, then replace it with a new one of 
    the same specifications. 
    b) Check the compressor accessories, including its thermal protector 
    and relay. In case the thermal protector is damaged, the compressor 
    cannot be powered on. If the relay is out of order, the motor will not run and 
    hum sound can be heard from it after the compressor is turned on, in that 
    case, shut it down immediately, otherwise, the motor windings will be 
    burned out in case this condition lasts longer. 
    c) Check the relay contacts and plugs to see if they are perfect and 
    work reliably. Poor contact may cause the motor not running or humming. 
    2) Check the circuit voltage to see whether it is normal. 
    Analysis of trouble 
    If the circuit voltage is obviously lower than its rated value, it will be 
    difficult to start the motor, and a hum sound can be heard from it. 
    Remedy  
    Measure the voltage with a voltmeter, if it is really too low, give 
    directions to the user for buying a stabilizer so as to step up the voltage, 
    thus normal operation can be achieved. 
    3) Check the thermal relay to see whether its contacts are closed. 
     Analysis of Trouble 
    The contacts of thermal relay sometimes may be open due to the 
    leakage of temperature sensing agent from the temperature sensor. 
    Remedy 
    Remove the relay cover to check up its contacts, if they are open, this 
    means that the original setting is not properly set or temperature sensing 
    agent has leaked out of the temperature sensor. Try to turn the adjusting 
    stem of this value in the direction of the lower temperature graduation, then 
    check the contacts to see whether they are closed. If they are still not 
    closed, dismantle the temperature sensing disc and then immerse it into 
    warm water to see whether the contacts actuate, if not, it can be 
    preliminarily determine that temperature sensing agent has leaked out, and 
    it must be replaced with a new thermostat. 
    4) Motor troubles and other electric faults 
    a) Motor windings have been burned or short-circuited between turns 
    Analysis of Trouble  
    When motor windings have been burned or short-circuited between 
    turns, the fuse will be blown repeatedly, and the blowout occurs particularly 
    at the instant when you close the knife switch. 
    Remedy  
    Check the terminals and the outer casing to see whether they are 
    short-circuited, and measure the resistance of each phase with an Maintenance Service and Trouble Shooting  
    						
    							18  avometer. If short circuit occurs or the resistance of a certain phase is low, 
    this means that short circuit does exist in the windings and/or between 
    turns, and insulation layers have been burned or deteriorated. A 
    megameter can be used in this inspection, too. I f the insulation resistance 
    is lower than 2 MΩ, this means that the insulation layer is already 
    breakdown. If the motor has been burned, repair it or replaced it with a new 
    one. 
    b) Fault of control relay 
    Analysis of Trouble  
    Overheat, burnout or wear of control relay contacts may occur generally. 
    All these will cause poor contact in electricity. 
    Remedy  
    Dismantle it to repair, or replace it with a new one. 
    c) Poor electric contactor in thermostat 
    Analysis of Trouble  
    Burnout of contactor and leakage of temperature sensing agent may 
    occur generally. 
    Remedy 
    Replace the old with a new one. 
    d) Check the terminals for loose connection and electric circuits for 
    other abnormal phenomena. 
    5) Mechanical faults of compressor 
    a) Seizing of shaft 
    This phenomenon is caused mostly by poor lubrication, such ad 
    insufficient quantity of lubricant, clogging in the lubricant oil line, or 
    intermittent lubricant oil supply. Dirt and other impurities in the lubricant oil 
    will increase its viscosity and cause the shaft to be seized. Copper plating 
    may also result in seizing of shaft. 
    b) Seizing of piston 
    This is caused by too small fit clearance between the piston and 
    cylinder or expansion due to heat. 
    Judgement of seizing shaft and piston: After the refrigerator has been 
    powered on, the compressor will not start and run, but a slight hum sound 
    can be heard, and several seconds later, thermal protective relay will 
    actuate and make the contacts open; this process will occur repeatedly, but 
    the compressor cannot be started. 
    E. Compressor won’t stop 
    Sometimes, the compressor will run continuously(for several hours or 
    run without end), If the food placed in the refrigerator is not too much, there 
    may be the following two situations: i) the refrigerator very low, this means 
    that the control system is probably out of order; ii) the control system works 
    normally, and there are troubles in the refrigerating system or other parts. 
    1) Temperature is set improperly 
    a) The temperature control knob is set to the “coldest” position. This Maintenance Service and Trouble Shooting  
    						
    							19  position is to be used for fast freezing or continuous running, its 
    temperature for power off is too low, therefore, the compressor won’t stop 
    and the temperature in the refrigerator becomes lower and lower .  
    b) Inspection method: check the temperature control knob to see 
    whether it is set in the position “coldest”. 
    2) Thermostat is malfunctioning and makes the compressor running 
    continuously 
    Analysis of Trouble 
    When the thermostat doesn’t work normally, it will make the compressor 
    run continuously, and hence very low temperature will be achieved in the 
    refrigerator. The fault is generally due to the fact that the contacts of the 
    thermostat cannot be released. 
    Remedy 
    Dismantle the thermostat and make a through checkup, if it is totally out 
    of functioning, replace it with a new one. 
    3) evaporation temperature is too high in refrigerating system, resulting 
    in lower refrigerating capacity and hence continuous running of compressor 
    Analysis of Trouble 
    Leakage of refrigerant and clogging in a refrigerating system will directly 
    affect its refrigerating capacity. Due to the reduction in its refrigerating 
    capacity, the refrigerator temperature cannot reach its rated value, the 
    thermostat won’t work, thus the compressor runs continuously. When the 
    evaporation temperature in the system is too high, the temperature sensing 
    agent in the temperature sensor is also hotter, therefore, the thermostat is 
    unable to cut off the power supply to the compressor and stop it. 
    Remedy 
    If it has been found that the refrigerant in the system is insufficient in 
    quantity, recharge it with refrigerant. In case clogging occurs, disassemble 
    the part where it is blocked. If the evaporation temperature is too high, 
    settle this problem with an appropriate quantity of refrigerant. 
    4) No stoppage of compressor due to damaged heat-insulation layer 
    inside case body and/or door seal 
    Analysis of Trouble 
    When the heat-insulation layer inside the case body deteriorates or the 
    door seal is not closely touches the door frame, the temperature in the 
    refrigerator will rise and makes the compressor running continuously. 
    Remedy 
    Check the heat-insulation layer for its damaged parts, repair it to 
    improve its heat-insulation property. If the door has deformed or the door 
    seal is not tightly sealed against the case body, repair them, respectively. 
    5) Too much food is placed in the refrigerator, or is placed too densely, 
    resulting in poor ventilation or poor conditions for temperature sensing, and 
    hence no stoppage of the compressor. 
    6) Too high ambient temperature, poorer ventilation and heat Maintenance Service and Trouble Shooting  
    						
    All Haier manuals Comments (0)

    Related Manuals for Haier Hrf 369aa Service Manual