Page 561

TL-130500-1001
DATA EQUIPMENT/12.0 The data system can handle a maximum of 120
ENGINEERINGdata ports. This section provides a general configuration
overview, detailed configuration rules and limitations, and
procedures for engineering the data system.
The following parameters describe the customer requirements to
configure or add on a data switch:
APM= Tl + T2 - T3
where 
Tl = number of asynchronous data terminal ports
requested (maximum speed = 19.2 Kbps) (VPLO or
VP20)T2 = number of asynchronous host...

Page 562

TL-130500-1001
Compute the hardware quantities as follows:
1. Compute the total of asynchronous terminals (with and without
modems), plus asynchronous host ports (with and without
modems), plus asynchronous modems in modem pools. This
total is the number of APMs or DPF/APM required.
2. Determine any other 
DFP/APM required.
3. The X.25 terminals and host ports must be split into two
groups, depending upon line speed. Those which operate at
19.2 kbps or less fall into the first group, which uses a SPM...

Page 563

TL-130500-1001
After completing step 9, list the quantities of hardware required:1.-APM
2.DFP/APM
3.SPM with RS-232-C connectors
4.SAPM with V.35 connectors
5.VPLC type VPLO
6.VPLC type VPLl
7.VPLC2 type VP20
8.VPLC2 type VP21
9.ADMP card (2-card pair) per PD-200 Data System
10.UCB cards
11. PR
12.PBE
13.PBT
14.NIC - one per Tl card set
Local Packet Bus12.1.1 Refer to Figures 12.1 through 12.6 for possible LPB
Configuration(Local Packet Bus) configurations. These figures also provides
placement of PR,...

Page 564

TL-130500-1001LFi

Page 565

TL-130500-1001
GROUP Cslot DOGROUP D slot DlOGROUP Aslot BO GROUP B slot 
89
Figure 12.4Example of Two Local Packet Buses in Groups B & D
GROUP C
slot DO GROUP 
Dslot D10GROUP A + B
slotGROUP AGROUP Bslot
A0B9
Figure 12.5Example of Two Local Packet Buses (LPB 0, LPB I) in Groups A& B and D
slot coGROUP CGROUP D
slot 
DlOGROUP A 
+ B
.---------------------------------------------
GROUP A
slot BOGROUP B slot B9
Figure 12.6Example of Two Local Packet Buses (LPB 0, LPB 
I) in Groups B and C & D
SVR 5210
S-l 87 

Page 566

TL-130500-1001
To connect the LPB into one bus in the top file of the PEC, add
jumper wires between slots X24 and X25, pins 36-40 and 86-90.To connect the LPB into one bus in the bottom file of the PEC,
add jumper wires between slots Y26 and Y28, pins 36-40 and
86-90.Example: X24 pin 36 to X25 pin 36
X24 pin 37 to X25 pin 37
X24 pin 40 to X25 pin 40
X24 pin 86 to X25 pin 86
S-l 88
8187X24 pin 90 to X25 pin 90SW 5210 

Page 567

TL-130500-1001
Frame Image Card
12.1.2 Once the LPB location has been determined, completePlacementthe frame image as the following flowchart indicates.
Place PR
Place PBE if needed and
PBT 
(UCB/T can replace
one PBT)PR, PBE, PBT, or 
UCB/Tcan only go in end slots
bAO, A10
BO, 
B9C6, Cl0
DO, DlOIf 
UCB/T is not used,
place UCBIt is recommended to place
UCB into the Get Started File
Place NIC PCB if
required
SVR 5210
Figure 12.7
Flowchart for Card Placement
8l87S-l 89 

Page 568

TL-130500-1001
Table 12.1 provides a worksheet for determining card slots and
cards required to support the data option.Table 12.1Worksheet for Data OptionTotalnumber of 
APMsrequired:
9Total number of high-speed SPMs required:
= s2
= item 5SPM High
10Number of ADMP card sets required:ADMP1
11Number of UCB cards required:UCB1
12Number of VPLC type 0 cards required:
= add items 6 and 8 and divide by 8
= APM + SPM low) 
/8 rounded up to the next
whole number
VPLO
13Number of VPLC type 1 cards required:
=...

Page 569

TL-130500-1001Table 12.1Worksheet for Data Option (Continued)= 
DFP/APM/8 rounded
up to the next whole
Number of slots used:
= 
add2timesitemlO+ items11,12,13,14,15 + item 17
= ADMP times 
2+ UCB + VPLO + VPLl +
VP20 + VP21 + PR + NIC
19Number of packet bus extender cards
required:
= 
Oifitem16is < or =64= 1 if 16 
> 64 or if data cards occupy both
files
NOTE: Depends upon configuration.PBE
20Number of packet bus terminator cards
required:
If 1 LPB is configured the UCB is normally
used to terminate the...

Page 570

TL-130500-1001
Voice Packet LineCard Configuration12.2 Table 12.2 provides configuration rules that apply to
both VPLC (FB 17226-A) and VPLC2 (FB 17246-A).
Table 12.2Voice Packet Line Card Type 0 and Type 1 Configuration Rules
TYPE OF VOICE
PACKET LINENUMBER OF
CARDPORTSTYPE OF VOICE PACKET LINE CARD
VPLC
type VPLO
VPLCtype VPLO
VPLC2type VP20(1) APM
(2) SPM running at less than or equal to 19.2 kbps
(1) APM
(2) SPM running at less than or equal to 64 kbps
(1) DFP/APM
(2) APM
(3) SPM running at less than...