Home > GTE > Communications System > GTE Omni Si Database Technical Practices Issue 1 Manual

GTE Omni Si Database Technical Practices Issue 1 Manual

Here you can view all the pages of manual GTE Omni Si Database Technical Practices Issue 1 Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 521

SVR 5210TL-130500-1001
List of Cards9.10 Tables 9.2 and 9.3 provide an alphabetical and a numerical
list of the cards used in the 
OMNI SI PABX for both voice and
data.NOTE: The FB mnemonic, which is placed in front of each card
number, stands for functional board.
The following list, provided for your reference, gives of all the
cards in a 
OMNI SI PABX. Figure 9.8 shows the system data
connections.
8187S-l 43 

Page 522

TL-130500-1001ATT1 2BCSR
rCHM85CIP/  
CP85E
DVCIP
FDCFMSD
INCKS
INCKLCM
MPB85
MPG16
/  PCMFS
I
/  PCMTS
- FB-20974-APCM Tone Source Card (Note 1)
PCONF
FB-51279-APCM Conference Card
PCOTFB-17202-A or BOAPCM Central Office Trunk (Note 2)
PDTMF
FB-17203-APCM Dual Tone Multi-frequency
PEMT
FB-17201 -APCM Two-Wire E&M Trunk (Note 2)
PFT
FB-51051 -APower Fail Transfer Card
S-l 44
8187SVR 5210
Table 9.2Alphabetical List sf Printed Circuit Boards 

Page 523

TL-130500-1001Table 9.2Alphabetical List of Printed Circuit Boards (Continued)
Tl B2FB-17192-ATl Buffer Circuit 2
TlSFB-20718-l ASupervisory Alarm Circuit for Tl
UCB/DCPFB-17231 -AUniversal Controller Board
VCIPFB-17235-AVoice Control Interface Processor
PILTFB-51280-A or BOAPCM Incoming Loop Trunk DID (Note 2)
VPLCFB-17226-AVoice Packet Line Card
VPLCDFB-17226-l AVoice Packet Line Card Derived
VPLC2FB-17246-AVoice Packet Line Card 2i
NOTES:
1. These cards cannot be removed or replaced without removing...

Page 524

TL-130500-1001Table 9.3Numerical List of Printed Circuit Boards
CARD NUMBERMNEMONICDESCRIPTION
IFB-15277-l A
FB-15278-ASILFDCSpan Interface and Output Format for TlFrame Detector Circuit for 
TlFB-15280-ALCM
FB-17187-A
PCMIFB-17188-A
TPl2FB-17189-A or BOA
PCMFS
FB-17192-A
Tl B2
FB-17201 -APEMT
FB-17202-A or BOA
PCOT
FB-17203-APDTMF
FB-17208-A
ATT12FB-17209-A
SIDML
FB-1721 O-APADIC
FB-17213-BOAMPG16
FB-17215-A
MPB85
FB-17217-AEPCMN
FB-17218-A
CHM85
FB-17220-BOAFMSD
FB-17225-A
CIPFB-17226-A
VPLC...

Page 525

TL-130500-1001Table 9.3Numerical List of Printed Circuit Boards (Continued)
NOTES:1. These cards cannot be removed or replaced without removing power from the cabinet in
which the card is located. (Refer to power-down procedures.)
2. These cards cannot be removed without first placing the card position in the maintenance
busy state. (Refer to power-down procedures.)
3.Disconnect the cables from the front of these cards before removing or replacing them.
SVR 5210
8187s-147 

Page 526

0
m, 

Page 527

TL-130500-1001VOICE10.0 The system supports a maximum of 256 lines or 64 trunks.
EQUIPMENT/TRAFFICIf optional features are used, this number is reduced.
ENGINEERINGThis section discusses:
0 The impact of line traffic on the system
* The impact of trunk traffic on the system
l The impact of features on the system
Voice Transportation10.1 Time slots transport analog (voice and tone)
Inside the PABXsignals inside the digital environment of the switch (Figure 10.1).
SW 5210voltage
voltageanalog
time
1011001...

Page 528

--TL-130500-1001
14131211109878543
21
i1
II
Level IBFigure 10.2PCM (Pulse Code Modulation) Low-usThe use of time slots permits the system to coordinate the
placement of a phone call:
0 When a call originates, the system assigns a series of memory
locations to the originator within 10 milliseconds after the
phone is taken off-hook. This is called assigning a time slot.
0 The time slot permits access to the signaling tones and timing
sequences needed to complete a connection. The access
allowed depends...

Page 529

TL-I 30500-l 001
Time Switching10.2 Each group within the system has access to certain time
GKlUpSslots (Figure 10.3).
0 System hardware is divided into six time switching groups:
- Each group has twenty-four time slots.
- The Get Started File has two time switching groups that
correspond with groups A and S.
- The Expansion File has four time switching groups - two
are located in group C and two are located in group D.
0 The Get Started File has a total of 48 time slots.
(8, The Expansion File has a...

Page 530

TL-130500-1001Group Usage of10.2.1 The OMNI SI software makes extensive use of the time
Time Switchingswitching group division. One such use permits the system to
coordinate the placement of a phone call:
l When a call originates, the system assigns a series of memory
locations to the originator within 10 milliseconds after the
phone is taken off-hook. This is referred to as assigning a
time slot.
l Depending upon the signaling mode used when dialing, and on
the feature invoked by the phone user, the...
Start reading GTE Omni Si Database Technical Practices Issue 1 Manual