Switching On/Off
To switch on the unit:
1. Switch on the circuit breaker on the rear of the unit (see 
Figure 1-4).
2. Press   (on/off button) on the top left of the control panel 
(see Figure 1-4).
After initialization the default scanning screen (2D mode) is 
displayed, the active probe being the one connected to the 
left most connector socket.
Switching off the unit
When the Vivid 7/Vivid 7 PRO is switched off, the system 
performs an...

Page 33

Getting started
Vivid7/Vivid7 PRO Users Manual19
FC092326-03
In case of total lock-
up of the system, 
hold the on/off but-
ton down a few sec-
onds to turn the 
system off.2. Select Shutdown.
The shutdown process takes a few seconds and is 
completed when the control panel illumination is turned off. 
To switch off before moving the unit, follow the additional steps 
below:
1. Set the circuit breaker to OFF.
2. Remove the plug from the mains power socket.
3. Secure the unit power cable around the cable...

Page 34

Getting started
20Vivid7/Vivid7 PRO Users Manual
FC092326-03
At the new location:
1. Secure the power plug in the wall outlet.
2. Switch on the circuit breaker on the rear of the unit 
(Figure 1-4).
3. Press   (on/off button) (Figure 1-4).
When turning on a system in standby it takes a few seconds 
before it responds. Do not push the on/off button again during 
this period (A second push will initiate a full shutdown).
If the power cable is removed from the wall outlet the system 
will remain in Standby...

Page 35

Getting started
Vivid7/Vivid7 PRO Users Manual21
FC092326-03
Moving and transporting the unit
Wheels
The wheels of the unit are controlled by the pedals situated 
between the front wheels of the unit (see Figure 1-5). 
Examine the wheels frequently for defects to avoid breaking or 
jamming.
 Figure 1-5: The Vivid 7/Vivid 7 PRO ultrasound unit pedalsWheel Characteristics
Front Swivel, swivel lock and full lock
Rear Swivel, but do not lock
1. Swivel lock pedal 
(Free position)
2. Full lock pedal 
(Free...

Page 36

Getting started
22Vivid7/Vivid7 PRO Users Manual
FC092326-03
Wheel operation
To engage the pedal in full lock
To release the brake
To engage swivel lock
Pedal Action
Press on pedal no. 2
Pedal Action
Press on pedal no.1
Pedal Action
Press on pedal no.1
12
12 

Page 37

Getting started
Vivid7/Vivid7 PRO Users Manual23
FC092326-03
To release swivel lock
Moving the unit
To prepare the unit to be moved
1. If not locked, push the keyboard console to its park position.
2. Turn the system off, including the circuit breaker (see 
page 18), and remove the plug from the wall.
3. Disconnect all cables linking the unit to any off-board 
peripheral devices and network.
Note the marks on 
each cable to recon-
nect them later.4. Secure the unit’s power cable.
5. Place all probes in...

Page 38

Getting started
24Vivid7/Vivid7 PRO Users Manual
FC092326-03
bar and push or pull. Do not attempt to move the unit using 
cables or probe connectors. Take extra care while moving 
the unit on inclines.
3. Ensure that the unit does not strike the walls or door 
frames.
4. Ensure the pathway is clear.
5. Move the unit slowly and carefully.
6. Use two or more persons to move the unit over long 
distances or on inclines.
Transpor ting the unit
Take extra care when transporting the unit by vehicle. In...

Page 39

Getting started
Vivid7/Vivid7 PRO Users Manual25
FC092326-03
brakes (see page 22).
2. Follow the installation procedure described on page 12.
Unit acclimation time
Following transport the unit may be very cold or hot. Allow the 
unit to acclimate before being switched on. Acclimation will 
take one hour for each 2.5 ºC increment when the unit’s 
temperature is below 10 ºC or above 40 ºC.
ºC02.557.510354042.5
ºF32 36.5 41 45.5 50 95 104 108.5
Hours43210023
ºC45 47.5 50 52.5 55 57.5 60
ºF113 117.5 122...

Page 40

Getting started
26Vivid7/Vivid7 PRO Users Manual
FC092326-03
System description
System over view
 Figure 1-6: the Vivid 7/Vivid 7 PRO ultrasound system
1
2
3
4
5
6
78
9
10
11
12
13 
Start reading GE Vivid 7 User Manual

Related Manuals for GE Vivid 7 User Manual

All GE manuals