2018/02  – Subject to change11 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Valve function
CodeCircuit symbolSizeDescription
101418
N, NK

2x 3/2-way valve, single solenoid
Normally open
Pneumatic spring return
Piston spool valve
With duct separation 1, 11 for valve NK
Size 18 only available for valve N
The function of a 5/3-way valve with mid-position pressurised 
can be implemented with these valves with initial position...

Page 12

Subject to change – 2018/0212 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Valve function
CodeCircuit symbolSizeDescription
101418
–

5/3E function, mid-position exhausted
The valve function “mid-position exhausted” is created using a 2x 3/2-way
valve, normally closed (code C, CK).
Pneumatic spring return
Piston spool valve
–

5/3B function, mid-position pressurised
The valve function “mid-position pressurised” is created...

Page 13

2018/02  – Subject to change13 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Additional pneumatic functions
CodeCircuit symbolSizeDescription
101418
AVacuum generator

Vacuum generation according to the ejector principle.
Vacuum slices of different widths for different suction capacities.
Combinations with a number of vacuum slices and/or directional control
function slices are possible on the same valve terminal.
In principle, an...

Page 14

Subject to change – 2018/0214 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Creating pressure zones
Different pressures at port 1 and 11
result in two pressure levels per valve.
This means, for example, that a cylin­
der drive can be advanced using high
pressure and retracted using low
pressure to save energy.The maximum number of pressure
zones possible is determined by the
combination of the following
components:Use of a separator...

Page 15

2018/02  – Subject to change15 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Examples: Compressed air supply
External pilot air supply, flat plate silencer at both ends
Compressed air supply via pneumatic
multiple connector plate:
code H
The diagram opposite shows an
example of the configuration and con­
nection of the compressed air supply
with external pilot air supply. Port
12/14 on the pneumatic multiple con­
nector plate is...

Page 16

Subject to change – 2018/0216 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Example: Creating pressure zones
CPV with separator plate T
With the CPV valve terminals up to
four pressure zones can be implem­
ented. The diagram shows an example
of the configuration and connection of
four pressure zones using separator
plate code T – with external pilot air
supply.Zone 2
Zone 1Zone 4
Zone 3
12 43
1Vacuum –0.9 bar
2Blast pulse 2 bar3Forward...

Page 17

2018/02  – Subject to change17 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
Compressed air supply and exhausting
The two end plates that pressurise
and exhaust the valve slices are
a characteristic feature of a CPV valve
terminal:
Large duct cross sections ensure
maximum flow rates even when
multiple valves are switched in
parallelLarge flat plate silencers in the end
plates
Internal/external pilot air supply
Each individual valve...

Page 18

Subject to change – 2018/0218 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
End plate combination for compressed air supply via end plate
CodeGraphical symbol
Type of pilot air supply (internal/external)SizeNote
101418
UInternal pilot air supply
82/84
3/5
12/14
11
1

Ports in right-hand end plate only
No pressure zone separation permissible
Not suitable for vacuum
VInternal pilot air supply
82/84
3/5
12/14
11
1

Ports in...

Page 19

2018/02  – Subject to change19 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
End plate combination for compressed air supply via pneumatic multiple connector plate
CodeGraphical symbol
Type of pilot air supply (internal/external)SizeNote
101418
YInternal pilot air supply
82/84
3/5
12/14
11
1

Ports on pneumatic multiple connector plate
Pressure zone separation only permissible
with separator plate (code T)
Maximum two pressure...

Page 20

Subject to change – 2018/0220 Internet: www.festo.com/catalogue/...
Valve terminals CPV, Compact Performance
Key features – Pneumatic components
End plate combination for compressed air supply via pneumatic multiple connector plate with flat plate silencer
CodeGraphical symbol
Type of pilot air supply (internal/external)SizeNote
101418
EExternal pilot air supply
82/84
3/5
12/14
11
1

Ports on pneumatic multiple connector plate
Exhaust air vented via flat plate silencer on
the right
Pressure zone...