Page 11
2018/02 – Subject to change11 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Valve function CodeCircuit symbolSizeDescription 101418 N, NK 2x 3/2-way valve, single solenoid Normally open Pneumatic spring return Piston spool valve With duct separation 1, 11 for valve NK Size 18 only available for valve N The function of a 5/3-way valve with mid-position pressurised can be implemented with these valves with initial position...
Page 12
Subject to change – 2018/0212 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Valve function CodeCircuit symbolSizeDescription 101418 – 5/3E function, mid-position exhausted The valve function “mid-position exhausted” is created using a 2x 3/2-way valve, normally closed (code C, CK). Pneumatic spring return Piston spool valve – 5/3B function, mid-position pressurised The valve function “mid-position pressurised” is created...
Page 13
2018/02 – Subject to change13 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Additional pneumatic functions CodeCircuit symbolSizeDescription 101418 AVacuum generator Vacuum generation according to the ejector principle. Vacuum slices of different widths for different suction capacities. Combinations with a number of vacuum slices and/or directional control function slices are possible on the same valve terminal. In principle, an...
Page 14
Subject to change – 2018/0214 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Creating pressure zones Different pressures at port 1 and 11 result in two pressure levels per valve. This means, for example, that a cylin der drive can be advanced using high pressure and retracted using low pressure to save energy.The maximum number of pressure zones possible is determined by the combination of the following components:Use of a separator...
Page 15
2018/02 – Subject to change15 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Examples: Compressed air supply External pilot air supply, flat plate silencer at both ends Compressed air supply via pneumatic multiple connector plate: code H The diagram opposite shows an example of the configuration and con nection of the compressed air supply with external pilot air supply. Port 12/14 on the pneumatic multiple con nector plate is...
Page 16
Subject to change – 2018/0216 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Example: Creating pressure zones CPV with separator plate T With the CPV valve terminals up to four pressure zones can be implem ented. The diagram shows an example of the configuration and connection of four pressure zones using separator plate code T – with external pilot air supply.Zone 2 Zone 1Zone 4 Zone 3 12 43 1Vacuum –0.9 bar 2Blast pulse 2 bar3Forward...
Page 17
2018/02 – Subject to change17 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components Compressed air supply and exhausting The two end plates that pressurise and exhaust the valve slices are a characteristic feature of a CPV valve terminal: Large duct cross sections ensure maximum flow rates even when multiple valves are switched in parallelLarge flat plate silencers in the end plates Internal/external pilot air supply Each individual valve...
Page 18
Subject to change – 2018/0218 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components End plate combination for compressed air supply via end plate CodeGraphical symbol Type of pilot air supply (internal/external)SizeNote 101418 UInternal pilot air supply 82/84 3/5 12/14 11 1 Ports in right-hand end plate only No pressure zone separation permissible Not suitable for vacuum VInternal pilot air supply 82/84 3/5 12/14 11 1 Ports in...
Page 19
2018/02 – Subject to change19 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components End plate combination for compressed air supply via pneumatic multiple connector plate CodeGraphical symbol Type of pilot air supply (internal/external)SizeNote 101418 YInternal pilot air supply 82/84 3/5 12/14 11 1 Ports on pneumatic multiple connector plate Pressure zone separation only permissible with separator plate (code T) Maximum two pressure...
Page 20
Subject to change – 2018/0220 Internet: www.festo.com/catalogue/... Valve terminals CPV, Compact Performance Key features – Pneumatic components End plate combination for compressed air supply via pneumatic multiple connector plate with flat plate silencer CodeGraphical symbol Type of pilot air supply (internal/external)SizeNote 101418 EExternal pilot air supply 82/84 3/5 12/14 11 1 Ports on pneumatic multiple connector plate Exhaust air vented via flat plate silencer on the right Pressure zone...