    							432-0010-00-12 Rev 100 — MD-Series Installation Guide 41
     MD-Series Reference
    By design, the camera image will freeze momentarily on a periodic basis during 
    the flat field correction (FFC) cycle. A shutter activates inside the camera and 
    provides a target of uniform temperature, allowing the camera to correct for 
    ambient temperature changes and provide the best possible image. Just prior to 
    the FFC, a small green square will appear  in the upper left corner of the screen.
    Note:  If you have a JCU, pressing and holding the COLOR button causes the 
    thermal camera to do an FFC operation.
    Multiple Cameras and/or JCUs on a single network
    You can configure the system with multiple  cameras and multiple JCUs on the 
    same network. More than one JCU can be used to control a given camera. The 
    camera will respond to commands from both  JCUs in the order the commands are 
    received across the network. Unpredic table behavior may result from users 
    sending conflicting commands from separate JCUs (for example, one user selects 
    white hot and the other selects black hot).  In general, the camera will respond to 
    the last command received and there is no way to set priority, given that IP 
    networks use a “best effort” delivery protocol.
    Note:  This behavior is true only of JCUs. If you are using the Web interface to 
    control the camera with a browser on a PC or smartphone, a message displays 
    prompting you to release control before the other Web device assumes it. 
    On Screen Messages
    In some circumstances, a status or alert message may appear on the video 
    screen. This section describes the mess ages and the appropriate actions that 
    may be necessary.
    Loading, please wait…
    Indicates the camera has power and is booting up. No action is needed; the 
    message will be removed when ca mera is ready for operation. 
    Reconnect network, now...
    Indicates the camera has detected a loopback termination on the Ethernet RJ45 
    connector and has reverted to the Factory Default network settings. Remove the 
    Ethernet RJ45 loopback termi nation adapter. The camera will then continue the 
    startup process under the factory default network configuration (with DHCP 
    dynamic IP addressing).
    No Network…
    Indicates the camera has lost connection with a previously available network. 
    Normally, when the camera is on a network, the IP address of the camera 
    displays. If the network connection is interr upted, this message displays instead.  
    						
    							 MD-Series Reference
    42432-0010-00-12 Rev 100 — MD-Series Installation Guide 
    Restoring the Factory Network Settings
    In some cases, it may be necessary to restore the network settings of the camera 
    to the original factory settings. At each  power up, the system transmits a packet 
    and then checks to determine if that sa me packet has been received. Detection 
    of the received packet indicates the camera has a custom loopback connector 
    installed on its Ethernet interface. The detection of the loopback packet cues the 
    camera to restore factory defaults and to revert to the same configuration and 
    behavior as when the camera left the factory.
    The following table describes the loopback connector.
    The RJ45 loopback termination ties pin 1 to  pin 3, and pin 2 to pin 6. The other 
    pins are not connected.
    Pin  Signal Tied to pin 
    1 Transmit + 3
    2 Transmit -  6
    3 Receive + 1
    4 Unused N/A
    5 Unused N/A
    6 Receive 
    -2
    7 Unused N/A
    8 Unused N/A 
    						
    							NOTES 
    						
    							FLIR Systems, Inc.
    CS World Headquarters
    FLIR Systems, Inc.
    70 Castilian Dr.
    Goleta, CA 93117
    USA
    PH:+ 1 805 964 9797
    PH:+ 1 877 773 3547 (Sales)
    PH:+ 1 888 747 3547 (Technical Support)
    FX: + 1 805 685 2711
    [email protected] 
    EUROPE
    CS Eurasian  Headquarters
    FLIR Systems CVS BV
    Charles Petitweg 21
    4847 NW Teteringen - Breda
    Netherlands
    PH: + 31 (0) 765 79 41 94
    FX: + 31 (0) 765 79 41 99
    [email protected]
    FLIR Systems, Inc.
    Corporate Headquarters
    FLIR Systems, Inc.
    27700A SW Parkway Ave.
    Wilsonville, OR 97070
    USA 
    PH: + 1 503 498 3547
    PH: + 1 877 773 3547
    FX: + 1 503 498 3153
    [email protected] 
    						
    All Flir manuals Comments (0)

    Related Manuals for Flir ThermovisionMDSeries Installation Manual