Home > Epson > Projector > Epson Projector Emp S1 User Manual

Epson Projector Emp S1 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Epson Projector Emp S1 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1734 Epson manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							50
    EMP-S1 User’s Guide Troubleshooting > When You Suspect a Problem
    fImage colours are poor, tinted green or tinted red/purple
     Are the image signal format settings 
    correct?
    If a component video device is connected and Computer is set as the 
    Image → Input Signal configuration menu setting, the projected 
    images will appear greenish. If a computer is connected and either 
    Component Video (YPbPr
    g ) or Component Video (YCbCr
    g) is set as 
    the Image → Input Signal configuration menu setting, the projected 
    images will appear red/purplish. Please select the appropriate setting for 
    the equipment you are using. ([Menu] button → Image → Input 
    Signal) sImage menu P.35
     Does the lamp need replacement?
    When the lamp is due for replacement, colours will weaken and the image 
    will become dark. Replace the lamp when this is the case. sLamp 
    replacement period P.56
     Has the image contrast been adjusted 
    correctly? ([Menu] button → Image → 
    Picture Quality → Contrast) 
    sImage menu P.35
     Has the colour been adjusted correctly? 
    ([Menu] button → Image → Picture 
    Quality → Color Temperature) 
    sImage menu P.35
     Has the saturation and tint been adjusted 
    correctly? ([Menu] button → Image → 
    Picture Quality → Saturation, Tint) 
    sImage menu P.35
     Has the image brightness been adjusted 
    correctly? ([Menu] button → Image → 
    Picture Quality → Brightness)
    sImage menu P.35
     Are the cables connected correctly? 
    sConnecting to a Computer P.12 , Connecting to Video Equipment 
    P.18
     When connecting to a computer
    Colours may not exactly match those displayed on the computer screen or 
    LCD screen, but this is normal and is not the sign of a problem. 
    						
    							51
    EMP-S1 User’s Guide Troubleshooting > When You Suspect a Problem
    fImage is darkfNo sound can be heard
     Does the lamp need replacement?
    When the lamp is due for replacement, colours will weaken and the image 
    will become dark. Replace the lamp when this is the case. sLamp 
    replacement period P.56
     Has the image brightness been adjusted 
    correctly? ([Menu] button → Image → 
    Picture Quality → Brightness)
    sImage menu P.35
     Has the image contrast been adjusted 
    correctly? ([Menu] button → Image → 
    Picture Quality → Contrast)
    sImage menu P.35
     Is A/V Mute activated?
    The projector may be in A/V Mute mode.
    Press the [A/V Mute] button on the remote control to cancel A/V Mute. 
    sA/V Mute P.28
     Is the volume turned down to the minimum 
    setting? ([Menu] button → Setting → 
    Volume) 
    sSetting menu P.38
     Is the audio source connected correctly?
    sPlaying sound from a computer P.14 , Playing sound from video 
    equipment P.19 
    						
    							52
    EMP-S1 User’s Guide Troubleshooting > When You Suspect a Problem
    fThe remote control does not workfThe power does not turn off (after the [Power] button is pressed)
     Is direct sunlight or strong light from 
    fluorescent lamps shining onto the remote 
    control infrared receiver?
    sUsing the Remote Control P.9
     Is the remote control too far from the 
    projector?
    The operating distance for the remote control is approximately 6m (20ft.). 
    sOperating range P.9
     When in use, is the remote control infrared 
    transmitter facing the remote control infrared 
    receiver on the projector?
    The operating angle for the remote control is approximately ±30½° 
    horizontally and approximately ±15½° vertically. sOperating range 
    P. 9
     Has the battery insulating tape been 
    removed?
    sBefore using the Remote Control P.9
     Is the battery dead?
    sChanging the battery (Remote Control, Presentation Remote 
    Controller) P.55
     Is the battery inserted correctly? 
     Is the battery installed?  The power indicator remains orange.
    This projector is designed so that the Power indicator remains lit even after 
    the power has been turned off. The Power indicator will switch off when 
    the power cable is disconnected from the electrical outlet.
     The cooling fan does not stop.
    After the [Power] button has been pressed, the cool-down period begins.
    After this, the Power indicator changes to a steady orange, and you can 
    then disconnect the power cable from the electrical outlet.
    Cool-down lasts for about 20 seconds. 
    						
    							53
    EMP-S1 User’s Guide
    Appendices
    Projector CareCleaningYou should clean the projector if it becomes dirty or if the projected 
    image starts to deteriorate.fCleaning the projector case
    Clean the projector case by wiping it gently with a soft cloth.
    If the projector is particularly dirty, moisten the cloth with water 
    containing a small amount of (ph) neutral detergent, and then firmly wring 
    the cloth dry before using it to wipe the projector case. After you have 
    done this, wipe the projector another time with a soft, dry cloth.
    fCleaning the lens
    Use a commercially-available air blower, or lens cleaning paper to gently 
    wipe the lens.
    c
    Be sure to read the separate Safety Instructions/World-Wide 
    Warranty Terms before proceeding.
    c
    Do not use volatile substances such as wax, alcohol or thinner to 
    clean the projector case. These can cause the case to warp and 
    make the surface coating peel off.
    c
    As the lens can be easily damaged, do not rub the lens with 
    harsh materials or subject the lens to shocks. 
    						
    							54
    EMP-S1 User’s Guide Appendices > Projector Care
    fCleaning the air filter
    If the air filter becomes clogged with dust, it can cause overheating and 
    damage the projector.
    Keeping the projector horizontal, use a vacuum cleaner to clean away the 
    dust from the air filter.p
     If the air filter is difficult to clean or if it is broken, it should be 
    replaced. Contact your dealer for a new air filter.
     Spare lamps are provided with new air filters. When replacing 
    the lamp, please replace the air filter at the same time. 
    						
    							55
    EMP-S1 User’s Guide Appendices > Projector Care
    Replacing consumablesfChanging the battery 
    (Remote Control, Presentation Remote Controller)
    Replacement battery: 1 × CR2025 lithium batteryA
    Remove the battery holder.While pressing the catch of the battery holder inwards, pull the battery 
    holder out.
    B
    Remove the old battery and insert the new one.Check the position of the (+) mark inside the battery holder to ensure 
    that the battery is inserted the correct way.
    C
    Replace the battery holder.Press the battery holder in until it clicks.
    c
    Keep batteries away from children to avoid the risk of accidents.
    If a child swallows the battery, contact your doctor immediately.
    p
    Please dispose of used batteries in accordance with local 
    waste disposal regulations. 
    						
    							56
    EMP-S1 User’s Guide Appendices > Projector Care
    fLamp replacement period
     It is time to change the lamp when the Replace Lamp message appears 
    in the bottom left hand corner of the screen at the commencement of 
    projection and remains for 30 seconds.
     It is also time to change the lamp when the Warning indicator flashes red 
    at 0.5 second intervals.
    fReplacing the lamp
    A
    Turn off the projector and wait for the cool-down 
    period to end. (Approx. 20 seconds)Remove the power cable and wait for the lamp to cool down. (Approx. 
    1 hour)
    B
    Open the lamp cover.Put your finger into the recess in the lamp cover hook, and lift up the 
    air filter to remove it.
    p
     The replacement message will appear after about 1900 hours of 
    use.
     When this message is displayed, please replace the lamp as 
    quickly as possible.
     The lamp may explode if you continue to use it beyond the 
    lamp replacement period.
     Some lamps may stop operating before the replacement 
    message is displayed. It is recommended that you have a 
    replacement lamp ready in case this happens.
     Replacement lamps can be purchased at your nearest dealer.
    c
     Wait until the lamp has cooled down sufficiently before 
    opening the lamp cover. It takes a further one hour after the 
    cool-down period has finished for the lamp to be cool enough.
     When the lamp is broken, replace it with a new lamp, or contact 
    your dealer for further advice. If replacing the lamp yourself, 
    be careful to avoid pieces of broken glass. 
    						
    							57
    EMP-S1 User’s Guide Appendices > Projector Care
    C
    Loosen the fixing screws holding the lamp in place.
    D
    Remove the old lamp.
    E
    Install the new lamp.Press the lamp until it clicks into place, then tighten the two fixing 
    screws.
    F
    Replace the lamp cover.First insert the tabs, and then press down on the opposite side until it 
    clicks into place.p
     Install the lamp securely. If the lamp cover is removed, the 
    lamp turns off automatically as a safety precaution. The 
    lamp will not turn on if the lamp or the lamp cover is not 
    installed correctly.
    • After replacing the lamp, be sure to reset the lamp 
    operating time.
     New air filters are included with replacement lamps. The 
    air filter should also be replaced when the lamp is replaced. 
    sLamp replacement period P.56
     Dispose of used lamps properly in accordance with your 
    local regulations. 
    						
    							58
    EMP-S1 User’s Guide Appendices > Projector Care
    fResetting the lamp operating time
    The projector has a built-in counter which keeps track of the lamp 
    operating time and causes the replacement warning message to be 
    displayed when the cumulative operating time reaches a certain point. 
    Therefore, the counter needs to be reset from the configuration menu, after 
    the lamp has been replaced with a new one.A
    Turn on the power and press the [Menu] button.
    B
    Select Lamp Hours Reset from the Reset menu, 
    using the [u][d][e] buttons.
    C
    Use the [l][r] buttons to select Yes, then press the 
    [e] button.The lamp operating time will be reset.
    p
    Please do not reset the lamp operating time except when the 
    lamp has been changed. Otherwise, the lamp operating time will 
    not be displayed correctly. 
    						
    							59
    EMP-S1 User’s Guide Appendices > Projector Care
    fReplacing the air filter
    Replacing the air filter can also be performed when the projector is 
    mounted to a ceiling.A
    Turn off the projector power, wait for the cool-down 
    period to end, then disconnect the power cable.Cool-down takes about 20 seconds.
    B
    Put your finger into the recess in the air filter hook, 
    and lift up the air filter to remove it.
    C
    Replace the air filter with a new one.Take out the old air filter and install the new one. Please ensure there 
    are no gaps between the air filter and the plastic grill.
    D
    Replace the air filter cover.First insert the tabs, and then press down on the opposite side until it 
    clicks into place.p
    Dispose of used air filters properly in accordance with your 
    local regulations. 
    						
    All Epson manuals Comments (0)