Parts, Names and Operations - 19 Rear Panel 1 Battery Cover 1
20 - Parts, Names and Operations Range of Remote Control Operations Depending on the distance and angle from the main unit’s light receiving area, there are cases where the remote control will not function. Ensure that the remote control is used within the fol- lowing conditions: Operable distance: Approximately 10 meters Operable range: Point ·Ensure that the [R/C ON OFF] switch is set at [ON] when using the remote control unit. ·Aim the remote control at the projector’s light-receiving area. ·There are cases where the operable distance (approximately 10 meters) of the remote control is diminished when signals are reflected off screens depending on the type of screen in use. ·Ensure that sunlight and florescent lighting is not shone directly into the projector’s light- receiving area. ·If the remote control will not function or malfunctions, there is a possibility that the batter- ies need changing. In this event, replace the batteries accordingly. ·Use the optional remote control receiver if it is to be used at a distance of 10m or more. (Front Panel) (Rear Panel) Approximately 30 degreesApproximately 30 degrees Light-emitting area on the remote control Approximately 15 degreesApproximately 15 degrees Approximately 15 degreesApproximately 15 degrees
Parts, Names and Operations - 21 Inserting the Remote Control Batteries The remote control batteries are inserted in accordance with the following procedure: 1Remove the Battery Cover. Apply pressure to the clip holding the Battery Cover, and then lift it upwards. 2Insert the batteries. Ensure that the batteries are aligned correctly with the “+” and “-“ labels on the remote control. 3Replace the cover. Apply pressure to the battery cover until it clicks firmly into place. Point ·Specified batteries: Two three-cell alkaline manganese batteries (LR6). ·The batteries should be replaced approximately once every three months when used for thirty minutes per day. Caution Ensure that unused batteries of the same type are used.
22 - Installation Procedure Installation Procedure Determines the projection angle and projection distance to ensure the most suitable screen display. Installation example The projector may be installed in locations that conform to the installation conditions and pro- jection methods. Viewing projected images from the front Viewing projected images from the front with a ceiling suspended projector Use the optional ceiling suspension unit and set the ceiling suspension parameter to [ON]. (see page 69) Viewing images projected onto half-transparent screens from the rear ·Set the rear parameter to [ON]. (see page 69) ·Ceiling suspension is also possible with the use of the optional ceiling suspension unit. Caution ·Do not block the ventilation outlet at the back of the projector or the Air Filter (suction inlet) on the rear panel. ·There are cases where material or paper get sucked onto the Air Filter on the rear panel when the projector is in use, so attention must be paid to prevent this. ·Do not place the projector in a location where it is subject to the direct air flow from air con- ditioners or heaters. ·When the projector is to be placed near a wall, ensure that there is at least 20cm of space between the wall and the projector. ·Do not cover the projector with table cloths or other material.
Installation Procedure - 23 Screen size and projection distance Determines the distance that the screen must be from the lens in order to obtain the required screen size. The projector’s Standard Lens is approximately a 1.4x zoom lens and the largest screen size is about 1.4 times the size of the smallest screen. Using the following table for reference purposes, install the projector so that the screen size is smaller than the screen. Point ·The projection distances listed above are the distances when the standard lense is in use. If optional lenses are to be used, refer to the relevant instruction manuals for further details. ·The screen size will become smaller when the trapezoid correction function is used. Screen SizeApproximate Projection Distance 30-inch (61 ×46cm)1.1m to 1.4m 40-inch (81 ×61cm)1.5m to 2.0m 60-inch (120 ×90cm)2.2m to 3.0m 80-inch (160 ×120cm)3.0m to 4.1m 100-inch (200 ×150cm) 3.7m to 5.1m 200-inch (410 ×300cm) 7.5m to 10.4m 300-inch (610 ×460cm)11.2m to 15.6m 7.5 -10.4 11.2- 15.6m 3.7 - 5.1 3.0 - 4.1 2.2 - 3.0 1.5 - 2.01.1 - 1.4 30-inch 40-inch 60-inch 80-inch 100-inch 200-inch 300-inch61X46 cm81X61 cm120X90 cm160X120 cm200X150 cm410X300 cm610X460 cm Screen Size Center of the lens Distance from the projector
24 - Installation Procedure Projection angles The optimum projection screen is acquired by placing the center of the projector’s lens and a right-angle to the screen. When viewing from the side* It is possible to move the projection position up and down with the lens shift function When viewing from the top or bottom Point Although the projection position can be adjusted with the foot lever (see page 45), there are cases where the screen will distort into a trapezoid shape. In this event, adjust the trap- ezoid distortion with the trapezoid correction function. (see page 46 ) A BA B A:B 10:Becomes 0A:B 5:Becomes 5 Upward 20 Downward 20
Connecting the projector to a computer - 25 Connecting the projector to a computer Switch off the power supply to the projector and computer before attempting to make the connection. Eligible computers There are computers with which connections cannot be established and computer that cannot be used for projection purposes even though a connection has been established. First of all, it is necessary to confirm that a connection can be established with the computer in use. Conditions for eligible computers Condition #1: The computer must be fitted with an image signal output port Check to ascertain that the computer is fitted with ports that will output image signals, such as the [RGB Port], the [Monitor Port] and the [Video Port]. If you have trouble confirming this, refer to chapter on external monitor connections in the computer’s instruction manual. There are computers, such as combined computer/monitor models and laptop models, that do not allow connections or for which optional external output ports must be purchased. Point Depending on the computer, there are cases when it is necessary to switch the image sig- nal output with the connection key ( , etc.,) and the settings. The table shown above provides examples for certain products. Refer to the computer’s instruction manual for further details. Condition #2: The resolution and frequency of the computer must be within the boundaries listed in the chart on the next page. Projection will not be possible if the computer does not support the output image signal resolutions and frequencies shown in the chart on the next page (there are cases where projection is possible, but vivid projection will not be possible). Confirm the image signal resolution and frequency with the computer’s instruction manual. There are also computers available that allow the output resolution to be amended. In this case, amend the parameters to fit within the ranges shown in the chart on the next page. NECPanasonicTo s h i b aIBMSONYFUJITSUMacintosh Fn+F3 Fn+F3 Fn+F5 Fn+F7 Fn+F7 Fn+F10 The control panel monitor and sound to be set to mirroring after rebooting.
26 - Connecting the projector to a computer SignalRefresh Rate (Hz)Resolution (Dots) Pixels (dots) Used During Resizing Dis- play (Resize On) Pixels (dots) Used During Real Display (Resize Off) Remarks PC98 640 ×4001366×854640×400 VGACGA 640 ×4001366×854640× 400 VGAEGA 640 × 3501366×748640×350 VGA 60 640 × 4801366×1024 640× 480 VESA 72/75/85/ 100/120640 ×4801366×1024 640×480 SVGA 56/60/72/75/ 85/100/120800 ×6001366×1024 800×600 XGA 43i/60/70/75/ 85/1001024 ×7681366×1024 1024× 768 SXGA 70/75/85 11 5 2 ×8641366×102411 5 2× 864 Virtual (Partial) Display SXGA 60/75/85 1280 × 9601366×1024 1280×960 Virtual (Partial) Display SXGA 43i/60/75/85 1280 ×10241366×1024 1280×1024 Virtual (Partial) Display SXGA+ 1400 ×10501328×996 1400×1050 Virtual (Partial) Display 1440 ×10801366×1024 1440×1080 UXGA 48i/60/65/70/ 75/80/851600 ×12001366×1024 1600×1200 Virtual (Partial) Display MAC13 640 × 4801366×1024 640×480 MAC16 832 ×6241366×1024 832×624 MAC19 1024 ×7681366×1024 1024×768 MAC21 11 5 2 ×8701356×1024 1152×870 Virtual (Partial) Display 640 ×4801366×1024 640×480 iMAC 800 ×6001366×1024 800×600 1024 ×7681366×1024 1366×768 NTSC 1366 ×1024 1366×768 4:3 ↔ 16:9, Selectable PA L 1366 ×1024 1366×768 4:3 ↔ 16:9, Selectable SECAM 1366 ×1024 1366×768 4:3 ↔ 16:9, Selectable SDTV (525i)60 1366 ×1024 (4 : 3)1366×768 (16 : 9) HDTV (750P)60 1366 ×768 (16 : 9) HDTV (1125i)60 1366 ×768 (16 : 9)
Connecting the projector to a computer - 27 In the case of the mini D-Sub 15 pin ·Connect the computer’s monitor port to the Computer #1 mini D-Sub 15 Port on the projector with the computer cable supplied. ·Set the switch to the analog setting (right-hand side) with the tip of a ballpoint pen or other pointed object. When the monitor port is the D-Sub 15 pin. Caution ·Switch off the power supply to the projector and computer before attempting to make the connection. Failure to observe this may result in damage. ·Confirm the shape of the cable connector and the shape of the port before making the con- nection. Applying excessive force when the direction or shape of the connector and port differ may result in defects and damage to the equipment. Computer #1 mini D-Sub15 Port Computer Cable (supplied with the projector) Monitor port (video port)
28 - Connecting the projector to a computer When the monitor port is the 5BNC (When connected to the second computer) Point ·Do not bind the Power Cable and the Computer Cable together. Failure to observe this may result in malfunctions. ·An adapter may be required when making the connection depending on the stand of the computer’s port. Refer to the computer instruction manual for further details. ·There are cases where the optional Mac Desktop Adapter and Mac Monitor Adapter are required when connecting up to a Macintosh. ·It is possible to establish connections with both the Computer #1 Port and the Computer #2 Port when two computers are to be connected. When the monitor port is 13w3 The Computer #1 Port is also connected to the D-Sub 15 port with the use of the conversion cable when the 13w3 port is used for connecting the computer’s monitor port to a work station. ·The projector’s computer #1 mini d-Sub 15 Port is connected to the computer’s monitor port (13w3) with the 13w3 ↔D-Sub 15 cable (available on the open market). ·Set the switch to the analog setting (right-hand side) with the tip of a ballpoint pen or other pointed object. Computer #1 mini D-Sub15 Port Computer Cable (supplied with the projector) Monitor port (video port) Monitor Port Computer #1 mini D-Sub15 Port 13w3 Cable (available on the open market)