1/5/99 ESC / VP Reference ManualLevel 3 Page 71 Gamma Data ( Group : 8 Item : 3 ) Sets gamma data directly from outside. [Function] Sets gamma data and sends 33 gradation data for each RGB. [Form] 1B 28 01 08 03 Parameter CS [Parameter] This parameter specifies RGB type and sets gamma data. R G B Type : 1 byte ( R : 00 G : 01 B : 02 ) Gamma Data : 33 byte ( No correction 0 to 32 ) Get Gamma Data [Function] Gets the gamma value (33 gradation) presently set. [Form] 1B 07 02 08 03 Parameter CS [Parameter] This parameter specifies RGB type and sets gamma data. R G B Type : 1 byte ( R : 00 G : 01 B : 02 ) [Return Value] Returns gamma data (33 gradation) for specified type. ( 33 byte ) & !(.)$
1/5/99 ESC / VP Reference ManualLevel 3 Page 72 CPU A / D Register ( Group : 8 Item : 4 ) Get CPU A / D Register [Function] Gets values of CPU A / D register data. [Form] 1B 07 02 08 04 Parameter CS [Parameter] This param eter specifies A / D register. L C P 1 A / D Register : ( 0 to 1 ) 1 byte L C P 2 A / D Register : ( 0 to 2 ) 1 byte Detecting Temp ( L V side) : 0 Detecting Temp (Lamp side) : 1 Detecting Temp (P B S side) : 2 [Return Value] Returns register data specified by A / D. Range of Return Value : 00 to FF
1/5/99 ESC / VP Reference ManualLevel 3 Page 73 Key Codes ( Group : 8 Item : 5 ) Get Key Codes [Function] Gets key codes of keys. [Form] 1B 06 02 08 05 EB [Return Value] Returns key codes have been pressed so far. Each key is represented by 1 bit, so if more than two keys are pressed at same time, it returns the sum of them. Key Codes : ( 5 byte ) S t a n d b y : 0000000001 S y n c + : 0000008000 C o m p u t e r : 0000000002 S y n c - : 0000010000 V i d e o : 0000000004 T r a c k i n g + : 0000020000 R e si z e : 0000000008 T r a c k i n g - : 0000040000 F r e e z e : 0000000010 M e n u : 0000080000 B l a n k : 0000000020 S e l e c t + : 0000100000 A u t o : 0000000040 S e l e c t - : 0000200000 M u t e : 0000000080 A d j r s t + : 0000400000 E n t e r : 0000000100 S e l e c t - : 0000800000 P o w e r : 0000000200 U p : 0001000000 S o u r c e : 0000000400 D o w n : 0002000000 P a u s e : 0000000800 L e f t : 0004000000 U s e r : 0000001000 R i g h t : 0008000000 V o l u m e + : 0000002000 Mouse Left Button : 0010000000 V o l u m e - : 0000004000 Mouse Right Button : 0020000000 Custom : 0040000000 ! /! 0!
1/5/99 ESC / VP Reference ManualLevel 3 Page 74 F R O M Checksum ( Group : 8 Item : 6 ) Making F R O M Checksum [Function] Makes checksum of FROM presently contained. [Form] 1B 06 01 08 06 CS [Parameter] Non (Note) Making the checksum takes 6 seconds. No commands are accepted during it. Get F R O M Checksum [Function] Gets the checksum of FROM. [Form] 1B 06 02 08 06 CS [Return Value] Returns the checksum of F R O M. * % !( /! 0!
1/5/99 ESC / VP Reference ManualLevel 3 Page 75 Mouse Movement ( Group : 8 Item : 7 ) Mouse Movement Setting [Function] Permits or inhibits mouse movements. [Form] 1B 07 01 08 07 Parameter CS [Parameter] This parameter specifies the data to Permit or Inhibit. Possible Data for Setting : Inhibit : 00 Permit : 01 Get State of Mouse Movement [Function] Gets the state of mouse movement. [Form] 1B 06 02 08 07 E9 [Return Value] Returns the state of mouse movement. *
1/5/99 ESC / VP Reference ManualLevel 3 Page 76 O S D Parameter ( Group : 8 Item : 8 ) O S D Parameter Setting [Function] Sets parameters of OSD display. (W hen displaying OSD, first you need to preset the following settings related to the OSD display.) [Form] 1B Size 01 08 08 Parameter CS [Parameter] ( For EMP/ELP-3500 ) This parameter sets the start coordinate for OSD display, line width, letter size, backcolor and flashing cycle. Start X-coordinate : Register value at the horizontal start position of Display RAM on the OSD screen ( 2 byte ) Start Y -coordinate : Register value at the vertical start position of Display RAM on the OSD screen ( 2 byte ) Magnification : 1 byte V magnification 1 / H magnification 1 = 0 V magnification 1 / H magnification 2 = 1 V magnification 2 / H magnification 1 = 2 V magnification 2 / H magnification 2 = 3 BackColor : 1 byte BLACK = 0 YELLOW = 3 CYAN = 6 RED= 1BLUE= 4WHITE= 7 GREEN = 2 MAGENTA = 5 BackColor of Inverted Characters : 1 byte BLACK = 0 YELLOW = 3 CYAN = 6 RED= 1BLUE= 4WHITE= 7 GREEN = 2 MAGENTA = 5 Flashing Cycle : 1 byte No flash = 0 Flashing Duty Rate23 % = 1 Flashing Duty Rate 50 % = 2 Flashing Duty Rate 75 % = 3 All Luster Blanking : 1 byte (Display BackColor / Non-display) O N = 1 O F F = 0 Display Mode : 1 byte (Set 1) Lines of Inverted Characters : 1 byte Specifies lines for inverted characters from the first line to eighth line in the values from 0 bit to 7 bit. Sets 1 for the byte of inverted characters line. ! # $ %# &# %# &#
1/5/99 ESC / VP Reference ManualLevel 3 Page 77 ( For EMP/ELP-5000, 5100, 7000, 7100 ) The parameters sets the start coordinate for OSD display, line width, letter size, backcolor and flashing cycle. Start X-coordinate : Start X-coordinate on the OSD screen (Pixel Unit 60 to 775) 2 byte Start Y-coordinate : Start Y-coordinate on the OSD screen (Pixel Unit 0 to 581) 2 byte Height of Characters : Height of Characters (Pixel unit 18 to 63) 1 byte OSD Backcolor : 1 byte BLACK = 0 CYAN = 3 YELLOW = 6 BLUE = 1 RED = 4 W HITE = 7 GREEN = 2 MAGENTA = 5 No backcolor = 8 Flashing Cycle : 1 byte No flash : 0 1 / 1 Flash : 1 1 / 1 Flash : 2 3 / 1 Flash : 3 #$% &% ! !
1/5/99 ESC / VP Reference ManualLevel 3 Page 78 O S D Character Data ( Group : 8 Item : B ) O S D Character Data Setting [Function] Sets characters to display OSD. (If displaying OSD, you first need to preset for OSD display in the OSD parameter settings.) [Form] 1B Size 01 08 0B Parameter CS [Parameter] (For EMP/ELP-3500) This parameter sets the display position on the OSD screen and number of characters in order of displaying character parameters and character codes repeatedly. Display position on the OSD screen : 2 byte [X-position : 1 byte] Specify the start position to display with character’s coordinates. Range : 0 to 23 [Y- position : 1 byte] Specify the start position to display with character’s coordinates. Range : 0 to 9 Character parameters : 1 byte [Color of Character : 4 bit] B L A C K : 0 B L U E : 4 R E D : 1 M A G E N T A : 5 G R E E N : 2 C Y A N : 6 Y E L L O W : 3 W H I T E : 7 [Flash / No Flash : 1 bit] Flash : 1 No Flash : 0 [Invert / No Invert : 1 bit] Invert : 1 No Invert : 0 ! Character Code (MITSUBISHI M35042-XXXSP : Character font code) : 1 byte
1/5/99 ESC / VP Reference ManualLevel 3 Page 79 ( For EMP/ELP-5000, 5100, 7000, 7100 ) The parameter sets the display position on the OSD screen and number of characters in order of displaying character parameters and character codes repeatedly. Parameter : Display position on the OSD screen : 2 byte [X-position : 1 byte] Specify the start position to display with character’s coordinates. Range : 0 to 32 [Y-position : 1 byte] Specify the start position to display with character’s coordinates. Range : 0 to 13 Character Parameters : 1 byte [Color of Character : 3 bit] B L A C K : 0 R E D : 4 B L U E : 1 M A G E N T A : 5 G R E E N : 2 Y E L L O W : 6 C Y A N : 3 W H I T E : 7 [Flash / No Flash : 1 bit] Flash : 1 No Flash : 0 [BackColor of Character : 4 bit] B L A C K : 0 R E D : 4 B L U E : 1 M A G E N T A : 5 G R E E N : 2 Y E L L O W : 6 C Y A N : 3 W H I T E : 7 No BackColor : 8 ! Character Code ( THOMSON STV942X : Character Font Code ) : 1 byte
1/5/99 ESC / VP Reference ManualLevel 3 Page 80 No Gamma ( Group : 8 Item : C ) No Gamma Setting [Function] Controls digital gamma correction. [Form] 1B 07 01 08 0C Parameter CS [Parameter] Possible Data for Setting : No : 00 Yes : 01 (only EMP/ELP-5000, 5100, 7000 and 7100 are available)