Home > Epson > Projector > Epson Projector Emp 7000 Specifications

Epson Projector Emp 7000 Specifications

    Download as PDF Print this page Share this page

    Have a look at the manual Epson Projector Emp 7000 Specifications online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1734 Epson manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  21
    Get Application State( Group  :  0   Item  :  B )
    Operating State of Application
     [Function] Inquires that now application has been working or not. Projector issues this command
    to the application. After the application received the command, returns a response
    packet to the projector. If the projector failed to receive the response packet,
    the projector interprets that the application was aborted or problems occurred on the
    communication channel, then cancels sending data after that.
    This command is issued for application regularly.
     [Form]     1B  06  02  00  0B  ED
     [Return Value]
    Returns response packets.( Application       Projector)
    
    	
    
    
      
      
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  22
    3.2  Screen Control
    Controls display screen. Each function is as follows.
    Input Source( Group  :  1   Item  :  0 )
    Input Source Adjustment
     [Function] Sets input source.
     [Form]     1B  07  01  01  00  Parameter  CS
     [Parameter]
    This parameter specifies the data of input source.
    Possible Data for Setting :
    No  S i g n a l           :    0 x 0 0 ( only EMP-ELP-3500 is available)
    P C 1   :    0 x 1 0
    P C 2   :    0 x 1 1
    Vi d e o           :    0 x 2 0
    
    Get Input Source
     [Function] Gets the present input source.
     [Form]     1B  06  02  01  00  F7
     [Return Value]
    Returns the present input source.
    
    	
    
    ./012345670
    Initialize Input Source
     [Function] Initializes input source.
     [Form]     1B  06  03  01  00  F6 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  23
    Input Mode( Group  :  1   Item  :  1 )
    Get Input Mode
     [Function] Gets the present input mode.
     [Form]     1B  06  02  01  01  F6
     [Return Value]
    Returns the present input mode.
    
    	
    
    
      
     
    n :    Mode Number
    ( For EMP/ELP-3500)
    Mode Name Mode Number Mode Name Mode Number
    No modes 0x00 SVGA56 0x08
    MAC16 0x01 MAC13 0x09
    XGA 0x02 VGA 0x0A
    SVGA72 0x03 PC98 0x0B
    SVGA75 0x04 EGA 0x0C
    VESA72 0x05 NTSC 0x0E
    SVGA60 0x06 PAL 0x0F
    VESA75 0x07 SECAM 0x10 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  24
    ( For EMP/ELP-5000, 5100, 7000 and 7100)
    Mode Name Mode Number Mode Name Mode Number
    No modes : 00 1024 x 768@60H z : 19
    E G A : 01 1024 x 768@70H z : 1A
    V G A    T E X T : 02 1024 x 768@75H z : 1B
    V G A 2 5 6 : 03 1024 x 768@85H z : 1C
    V G A E G A : 04 N T S C : 1D
    VG A C G A : 05 P A L : 1E
    P C -9 8    Normal : 06 S E C A M : 1F
    M A C 19” R G B : 07 Not supported : 20
    M A C 19” R G B 60 : 08
    M A C 16” R G B : 09
    M A C      II 13” R G B : 0A
    M A C      L C 13” R G B : 0B
    M A C      L C 12” R G B : 0C
    640 x 350@85H z : 0D
    640 x 400@85H z : 0E
    720 x 400@85H z : 0F
    640 x 480@60H z : 10
    640 x 480@72H z : 11
    640 x 480@75H z : 12
    640 x 480@85H z : 13
    800 x 600@56H z : 14
    800 x 600@60H z : 15
    800 x 600@72H z : 16
    800 x 600@75H z : 17
    800 x 600@85H z : 18 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  25
    Freeze( Group  :  1   Item  :  2 )
    Freeze Setting
     [Function] Sets freeze setting or cancels it.
     [Form]     1B  07  01  01  02  Parameter  CS
     [Parameter]
    This param eter specifies the data for Freeze ON/OFF.
        Possible Data for Setting :
    O F F  :    00
    O N    :    01
    
    
    Get Freeze State
     [Function] Gets the present freeze state.
     [Form]     1B  06  02  01  02  F5
     [Return Value]
    Returns the present freeze state.
    
    	
    
    
      
     
    Initialize Freeze State
     [Function] Initializes freeze state.
     [Form]     1B  06  03  01  02  F4 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  26
    Pause( Group  :  1   Item  :  3 )
    Pause Setting
     [Function] Sets pause setting or cancels it.
     [Form]     1B  07  01  01  03  Parameter  CS
     [Parameter]
    This parameter specifies the data for Pause ON/OFF.
        Possible Data for Setting :
    O F F :    00
    O N  :    01
    
    Get Pause State
     [Function] Gets the present pause state.
     [Form]     1B  06  02  01  03  F4
     [Return Value]
    Returns the present pause state.
     
    	
    
    
      
     
    Initialize Pause State
     [Function] Initializes pause state.
     [Form]     1B  06  03  01  03  F3 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  27
    3.3 Audio Control
    Controls audio. Each function for the Audio Control is as follows.
    Volume( Group  :  2   Item  :  0 )
    Adjusting Volume Value
     [Function] Sets volume for the sound input presently selected.
     [Form]     1B  07  01  02  00  Parameter  CS
     [Parameter]
    This param eter specifies value for the setting.
    
    
    Get Volume Value
     [Function] Gets the present volume value.
     [Form]    1B  06  02  02  00  F6
     [Return Value]
    Returns the present volum e value.
    
    	
    
    
      
     
    Initialize Volume Value
     [Function] Initializes volume value.
     [Form]    1B  06  03  02  00  F5 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  28
    Tone( Group  :  2   Item  :  1 )
    Adjusting Tone Value
     [Function] Sets tone value for the sound input presently selected.
     [Form]     1B  07  02  01  02  01  Parameter  CS
     [Parameter]
    This parameter specifies tone value to set.
    
    
    Get Tone Value
     [Function] Gets the present tone value.
     [Form]     1B  06  02  02  01  F5
     [Return Value]
    Returns the present tone value.
    
    	
    
    
      
     
    Initialize Tone Value
     [Function] Initializes tone values.
     [Form]     1B  06  03  02  01  F4 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  29
    Loudness( Group  :  2   Item  :  2 )
    Loudness Setting
     [Function] Sets Loudness ON or OFF to the sound input presently selected.
     [Form]     1B  07  01  02  02  Parameter  CS
     [Parameter]
    This parameter specifies the data for Loudness ON/OFF.
        Possible Data for Setting :
    O F F  :    00
    O N    :    01
    
    
    
    Get Loudness State
     [Function] Gets the present loudness value.
     [Form]      1B  06  02  02  02  F4
     [Return Value]
    Returns the present loudness value.
     
    	
    
    
      
     
    Initialize Loudness State
     [Function] Initializes loudness state.
     [Form]      1B  06  03  02  02  F3 
    						
    							1/5/99
    ESC/VP Reference ManualLevel 3
    Page  30
    Mute( Group  :  2   Item  :  3 )
    Mute Setting
     [Function] Sets mute ON or OFF to the sound input presently selected.
     [Form]     1B  07  01  02  03  Parameter  CS
     [Parameter]
    This parameter specifies data for Mute ON/OFF.
        Possible Data for Setting :
    O F F  :   00
    O N   :    01
    
    
    Get Mute State
     [Function] Gets the present mute state.
     [Form]     1B  06  02  02  03  F3
     [Return Value]
    Returns the present mute state.
    
    	
    
    
      
     
    Initialize Mute State
     [Function] Initializes mute state.
     [Form]     1B  06  03  02  03  F2 
    						
    All Epson manuals Comments (0)

    Related Manuals for Epson Projector Emp 7000 Specifications