Page 61

1/5/99
ESC / VP Reference ManualLevel 3
Page 61
Change Screen Mode ( Group  :  6   Item  :  7 )
Change Screen Mode Setting
  [Function]   Sets modes for changing screen.
  [Form]       1B  07  01  06  07  Parameter  CS
  [Parameter]
This parameter specifies the data to modes when changing screens.
Possible Data for Setting :
O F F :   00
Left top    Right bottom :   01
Left    Right :   02
Edge    Center :   03

	
Get Change Screen Mode
  [Function]   Gets the modes when changing...

Page 62

1/5/99
ESC / VP Reference ManualLevel 3
Page 62
User Gamma ( Group  :  6   Item  :  8 )
User Gamma Setting
    [Function]      Sets user gamma data and sends the ideal gamma data which is 33 gradation.
        The gamma data is reflected immediately after sending all data. But while displaying
        blank screen, the gamma is not reflected.
  [Form]       1B  27  01  06  08  Gamma Data  CS
    [Gamma Data]
        Gamma Data :          33 byte       (Ideal Gamma Data : 0 to 32)
	

 

...

Page 63

1/5/99
ESC / VP Reference ManualLevel 3
Page 63
3.8 Custom
Sets added function that user can program. Each function for Custom is as shown below.
Effect Key ( Group  :  7   Item  :  0 )
Effect Key
    [Function]      Indicates that effect keys are pressed.
  [Form]       1B  07  01  07  00  Parameter  CS
  [Parameter]
    This parameter specifies the data to effect keys.
    Possible Data for Setting :
Effect 1 Key      : 00
Effect 2 Key      : 01
Effect 3 Key      : 02
Effect 4 Key      : 03
Effect 5...

Page 64

1/5/99
ESC / VP Reference ManualLevel 3
Page 64
Custom Key Function ( Group  :  7   Item  :   1 )
Custom Key Function Setting
    [Function]      Sets the function assigned to custom keys.
  [Form]       1B  07  01  07  01  Parameter  CS
  [Parameter]
    This parameter specifies the data to effect keys.
    Possible Data for Setting :
Zoom      : 00
Preview      : 01
Strobe  : 02
	
Get Custom Key Function
    [Function]      Gets the present custom key function.
  [Form]       1B  06...

Page 65

1/5/99
ESC / VP Reference ManualLevel 3
Page 65
Counts of Strobe Frames ( Group  :  7   Item  :  2 )
Counts of Strobe Frames Setting
    [Function]      Sets number of frames.
  [Form]       1B  07  01  07  02  Parameter  CS
  [Parameter]
 This parameter specifies the data to the number of frames.
 Possible Data for Setting :
Frames 4   :  00
Frames 9   :  01
Frames 16  :  02

	
Get Counts of Strobe Frames
    [Function]      Gets the present number of frames.
  [Form]       1B  06  02...

Page 66

1/5/99
ESC / VP Reference ManualLevel 3
Page 66
Counts of Strobe Time ( Group  : 7   Item  :  3 )
Counts of Strobe Time Setting
    [Function]      Sets numbers of strobe time.
  [Form]       1B  07  01  07  03  Parameter  CS
  [Parameter]
This parameter specifies numbers of strobe time.
	
Get Counts of Strobe Time
    [Function]      Gets the present number of strobe time.
  [Form]       1B  06  02  07  03  EE
  [Return Value]
Returns the present number of strobe time.
 	...

Page 67

1/5/99
ESC / VP Reference ManualLevel 3
Page 67
3.9  Hardware Control
Controls hardware directly. Each function of the Hardware Control is as shown below.
Change operation mode to Circuit Adjustment mode to control hardware.
I 2 C ( Group  :  8   Item  :  0 )
Hardware Control from I 2 C bus
    [Function]      Controls hardware by I 2 C bus.
  [Form]       1B  Size  01  08  00  Parameter  CS
  [Parameter]
This parameter specifies the action of    I 2 C bus.
W hen you want to set values for each device,...

Page 68

1/5/99
ESC / VP Reference ManualLevel 3
Page 68
Get State of Hardware from I 2 C Bus
    [Function]      Gets the state of hardware from I 2 C Bus.
  [Form]       1B  Size  02  08  00  Parameter  CS
  [Parameter]
This parameter specifies the action of I 2 C Bus.
W hen you want to get values from each device, refer the I 2 C bus communication system
of the devices and match the following I 2 C bus action.
    I 2 C Bus Action :
Start Requirement                                       : 00
Stop Requirement...

Page 69

1/5/99
ESC / VP Reference ManualLevel 3
Page 69
Memory ( Group  :  8   Item  :  1 )
Memory Data Setting
  [Function]   W rites memory data.
  [Form]       1B 0A  01  08  01  Parameter  CS
  [Parameter]
This parameter specifies the addresses to write data and set data to memory.
    Address   :   3 byte
    Set Data  :   1 byte
	
  
! 

Get Memory Data
    [Function]      Gets values of Memory.
  [Form]       1B  09  02  08  01  Parameter  CS
  [Parameter]
This parameter...

Page 70

1/5/99
ESC / VP Reference ManualLevel 3
Page 70
VS 2000 ( Group  :  8   Item  :  2 )
VS 2000 Data Setting
    [Function]      Controls VS2000. (Sets 1byte data to the register of VS2000.)
  [Form]       1B  0B  01  08  02  Parameter  CS
  [Parameter]
This parameter specifies the first address, off-set address and set data of VS2000.
        VS 2000 First Address :  3 byte
        VS 2000 Off-set Address :  1 byte
    VS 2000 Set Data :       1 byte



 	

...