Page 31

1/5/99
ESC/VP Reference ManualLevel 3
Page  31
SPECIALIZER( Group  :  2   Item  :  4 )
Adjusting Specializer
 [Function] Sets specializer to the sound presently selected.
 [Form]     1B  07  01  02  04  Parameter  CS
 [Parameter]
This parameter specifies the data supports for the sound effect.
      Possible Data for Setting :
No sound effect   :    00
Normal           :    01
Wide              :    02


Get Specializer
 [Function] Gets the present specializer.
 [Form]     1B  06  02...

Page 32

1/5/99
ESC/VP Reference ManualLevel 3
Page  32
3.4  PC Image Control
Controls the images for the PC.    Each function for PC is as shown below.
Brightness( Group  :  3   Item  :  0 )
Adjusting Brightness Value
 [Function] Sets brightness for screens.
 [Form]     1B  07  01  03  00  Parameter  CS
 [Parameter]
This parameter specifies the brightness to set.

Get Brightness Value
 [Function] Gets the present brightness.
 [Form]     1B  06  02  03  00  F5
 [Return Value]
Returns the...

Page 33

1/5/99
ESC/VP Reference ManualLevel 3
Page  33
Contrast( Group  :  3   Item  :  1 )
Adjusting Contrast Value
 [Function] Sets contrast values for screens.
 [Form]     1B  07  03  01  Parameter  CS
 [Parameter]
This parameter specifies the contrast values to set.

Get Contrast Value
 [Function] Gets the present contrast values.
 [Form]     1B  06  02  03  01  F4
 [Return Value]
Returns the present contrast values.
 
	


  
 
Initialize...

Page 34

1/5/99
ESC/VP Reference ManualLevel 3
Page  34
Synchronization( Group  :  3   Item  :  2 )
Sync Adjustment
 [Function] Sets phases for sampling clock.
 [Form]     1B  07  01  03  02  Parameter  CS
 [Parameter]
This parameter specifies the sync value to set.


Get Sync Value
 [Function] Gets the present sync values.
 [Form]     1B  06  02  03  02  F3
 [Return Value]
Returns the present sync values.

	


  
 
Initialize Sync Value...

Page 35

1/5/99
ESC/VP Reference ManualLevel 3
Page  35
Tracking( Group  :  3   Item  :  3 )
Adjusting Tracking Value
 [Function] Adjusts number of sample for input signal.
 [Form]     1B  07  01  03  03  Parameter  CS
 [Parameter]
This parameter specifies the tracking value to set.

Get Tracking Value
 [Function] Gets the present tracking values.
 [Form]     1B  06  02  03  03  F2
 [Return Value]
Returns the present tracking values.

	


  
 ...

Page 36

1/5/99
ESC/VP Reference ManualLevel 3
Page  36
Tracking Base( Group  :  3   Item  :  4 )
Get Tracking Base
 [Function] Gets the present tracking base.
 [Form]     1b  06  02  03  04  EE
 [Return Value]
Returns the present tracking base.
 
- 


  
 
& ( 

Page 37

1/5/99
ESC/VP Reference ManualLevel 3
Page  37
Mouse/Serial Port fixed( Group  :  3   Item  :  5 )
Designating Mouse/Serial Port fixed
 [Function] Sets mouse/serial port fixed.
 [Form]     1B  07  01  03  05  Parameter  CS
 [Parameter]
This parameter specifies the data to support for ports.
Possible Data for Setting :
Not fixed    :    00
P C 1        :    01
P C 2       :    02

Get State of Mouse/Serial Port fixed
 [Function] Gets the present state of mouse/serial port fixed....

Page 38

1/5/99
ESC/VP Reference ManualLevel 3
Page  38
Color Red Level( Group  :  3   Item  :  6 )
Adjusting Color Red Level Value
 [Function] Sets color red level for the screen to the input source presently selected.
 [Form]    1B  07  01  03  06  Parameter  CS
 [Parameter]
This parameter specifies the red level to set.
	
Get Color Red Level Value
 [Function] Get the present color red level to the input source presently selected.
 [Form]     1B  06  02  03  06  EF
 [Return Value]
Returns...

Page 39

1/5/99
ESC/VP Reference ManualLevel 3
Page  39
Color Green Level( Group  :  3   Item  :  7 )
Adjusting Color Green Level Value
 [Function] Sets color green level for screens to the input source presently selected.
 [Form]     1B  07  01  03  07  Parameter  CS
 [Parameter]
This parameter specifies the color green level to set.

Get Color Green Level Value
 [Function] Gets the present color green level to the input source presently selected.
 [Form]     1B  06  02  03  07  EE
 [Return...

Page 40

1/5/99
ESC/VP Reference ManualLevel 3
Page  40
Color Blue Level( Group  :  3   Item   :  8 )
Adjusting Color Blue Level
 [Function] Sets color blue level for screens to input source presently selected.
 [Form]     1B  07  01  03  03  Parameter  CS
 [Parameter]
This parameter specifies the color blue level to set.


Get Color Blue Level Value
 [Function] Gets the present color blue level to the input source presently selected.
 [Form]     1B  06  02  03  03  ED
 [Return Value]
Returns...