    Monitoring window layout
    *1 When Temperature level display group view is set to On at 
    Environment setup in the Tool menu, an icon indicating the internal 
    temperature of the projector will be displayed on top of the projector 
    icon. The default setting is Off.
    *2 Check the following items.
     Check that the projectors power is turned on. 
     Check that the LAN cable is connected.
     Check that Network Monitoring is set to ON or Standby Mode 
    is set to Network ON in the projectors configuration menu.
    *3 Check that the projector has been correctly connected to the network.
    *4 You can display the Replace Lamp warning at any time preset in 
    Environment setup in the Tool menu.
    fSelecting display items
    You can select only the required items to be displayed in Detail list view.PROCEDURE
    Select Option from the View menu.
    The Option window will be displayed.
    Error information:Shows a notification or warning/problem status 
    using the following icons.
    Clean Air Filter 
    Notice
    Lamp Error
    Replace Lamp
    *4
    Lamp failure at 
    power on
    High-temperature 
    warning
    High internal 
    temperature error
    Replace Air Filter
    Internal Error
    No Air Filter
    Fan error
    Low Air Flow
    Sensor error
    Air Flow Sensor Err.
    Supply System Error 
    (Ballast)
    Low air flow error
    Auto Iris Error
    Air filter air flow 
    sensor error
    Other error
    Lamp Cover Open
    TIP
     The projector information that is generated when a problem is 
    detected is stored until EMP Monitor is closed. The EMP Monitor 
    displays will not be updated automatically even if the projector status 
    returns to normal. Click [Refresh] in the main window to update the 
    status.
     Detectable error information differs with the projector you are using. 1 
    						
    							21
    Monitoring window layout
    Select the check box of the item you want to display.Click [OK].When all of the details of the item cannot be displayed 
    in Detail list view, drag the boundary line on the 
    right of the item name so that the view is extended to 
    the desired width.
    fSorting lists
    You can sort detailed lists by using a specific row as a sort key, such as 
    projector name order or IP address order.PROCEDUREClick the item name of the row you want to use as the sort 
    key.
    Searching for desired icons (Projector list)
    The Projector list feature is useful for searching in lists when many 
    groups and projectors are registered and the icon you are looking for is not 
    displayed on screen.  PROCEDURESelect Projector list from the View menu. The Projector list lets you check the registration details for groups in a 
    hierarchical diagram. When you click on an icon, Grouping view and 
    Detail list view are scrolled so that the selected icon is displayed in the 
    window.
    234
    With Projector list, temperature 
    level icons are not displayed 
    regardless of the setting of 
    Temperature level display group 
    view at Environment setup.  
    						
    							22
    Monitoring window layout
    Monitoring using the system tray
    The projector statuses are always displayed as icons in the system tray, 
    even when Grouping view or Detail list view is not always displayed, 
    and the statuses can be checked by the icon patterns. 
    When the configuration menus are set using the following operations, an 
    icon appears in the system tray and the status can be monitored by means 
    of the icons pattern.
    PROCEDURE
    Select Environment setup from the Tool menu.
    The Environment setup window will be displayed.Select Resident in the task tray.Click [OK].
     : No problem
     : Problem
    123
    TIP
     Right-click the icon in the system tray to open a pop-up menu to 
    select the Open the main screen or Exit.
     If Register at start up in the Environment set up is selected, 
    EMP Monitor starts automatically when the computers power is 
    turned on. When using EMP Monitor under Windows Vista, you 
    must have administrator authority in order to use this function. 
    						
    							23
    Monitoring window layout
    Displaying projectors with problem or warning statuses in a list
    You can display a list of only the projectors which have a problem or 
    warning status.PROCEDURESelect Warning and Error Projector list from the View 
    menu.The following Warning and Error Projector list window will be 
    displayed.The icon patterns and their meanings are explained below.
    If you move the 
    mouse pointer over 
    the icon, details of 
    the error and the 
    remedy will be 
    displayed.
    If you double-click in 
    a line, the properties 
    for that projector will 
    be displayed. 
    s p.25
    Ty p e : Shows the group or projector status. sp.17Display name: Shows the display name.Power: Shows the power on status for the projector.
    Power on and normal 
    status
    Power on and 
    abnormal status
    Power off and normal 
    status
    Power off and 
    abnormal status
    Lamp Hours: Shows the lamp operating time for the projector.Source: Shows the input source that has been selected for the projector.
    Computer or 
    Computer1
    Video(BNC)
    Computer2
    DVI or HDMI 
    (Digital)
    BNC
    D-Video
    S-Video
    EasyMP
    Video(RCA)
    Temperature level: The following five icons display the differing 
    internal temperature status of the projector.
    Internal temperature 
    normal
    High-temperature 
    warning
    Internal temperature 
    normal
    Internal temperature 
    error
    High-temperature 
    warning 
    						
    							24
    Monitoring window layout
    *You can display the Replace Lamp warning at any time preset in 
    Environment setup in the Tool menu.
    Checking properties in detail
    You can check the properties of groups and projectors in detail.
    fDisplaying group properties
    You can use either of the following methods to display the properties.
    • Displaying the properties for all groups in Grouping view
    Right-click in Grouping view and then select Property.
     Displaying properties for specified groups
    Right-click an icon in Grouping view and then select Property.
    Error information:Shows the warning or problem status using the 
    following icons.
    Replace Lamp*
    Lamp Error
    High-temperature 
    warning
    Lamp failure at 
    power on
    Replace Air Filter
    High internal 
    temperature error
    No Air Filter
    Internal Error
    Low Air Flow
    Fan error
    Air Flow Sensor Err.
    Sensor error
    Low air flow error
    Supply System Error 
    (Ballast)
    Air filter air flow 
    sensor error
    Auto Iris Error
    Lamp Cover Open
    Other error
    TIP
    Detectable error information differs with the projector you are using. 
    If you double-click 
    in a line, the 
    properties for that 
    group or projector 
    will be displayed. 
    						
    							25
    Monitoring window layout
    fDisplaying projector properties
    Right-click on a projector icon in Grouping view or Detail list view 
    and select Property.
    Displaying and deleting logs
    In your web browser, you can check a transmission log of content such as 
    what has been controlled by the EMP Monitor, projector errors. You can 
    delete logs once you have checked them.
    fDisplaying logs
    PROCEDURESelect Log - show from the View menu.
    The web browser will open and the communication logs up until that 
    time will be displayed.
    fDeleting logsPROCEDURESelect Log - Delete from the View menu.
    When the confirmation message is displayed, click [OK].
    All logs will be deleted and details of EMP Monitor control 
    operations and details of projector errors from that point onward will 
    be recorded in a new log.
    Displays the 
    projector firmware 
    version.
    TIP
    When Log output is set to On at Environment setup in the 
    Tool menu, transmission logs are stored. The default setting is 
    Off. 
    						
    							26
    Using the control functionsCarrying out control using control buttons
    Click the icon of a projector to be controlled in Grouping view or Detail 
    list view, and click a control button to enable control of only that selected 
    projector.
    You can also enable control of all selected projectors by selecting more 
    than one projector in Grouping view or Detail list view and clicking a 
    control button. The methods of selecting more than one projector at the 
    same time are as follow.
     If you select a group icon in Grouping view, all projectors that have
    been registered in that group and that are set to be monitored can be 
    controlled at the same time.
     Hold down the [Ctrl] key on the keyboard while clicking on the desired 
    icons.
     Use drag and drop to select a range of desired icons.
    The following table shows the meanings of the control buttons.
    Control buttons
    Power On
    Turns the projector power on.
    Power Off
    Turns the projector power off.
    Switch source
    Computer 1
    Switches the input source to the [Computer1] port 
    or [Computer] port.
    Switch source
    Computer 2
    Switches the input source to the [Computer2] port.
    Switch source 
    BNC
    Switches the input source to the [BNC] port.
    Switch source 
    S-Video
    Switches the input source to the [S-Video] port.
    Switch source 
    Video(RCA)
    Switches the input source to the [Video] port or the 
    [Video 2] port.
    Switch source 
    Video(BNC)
    Switches the input source to the [Video1] port.
    Switch source 
    DVI, HDMI
    Switches the input source to the [DVI] port or 
    [HDMI] port.
    Switch source 
    D-Video
    Switches the input source to the [D4] port.
    Switch source 
    EasyMP
    Switches to EasyMP or EasyMP.net.  
    						
    							27
    Using the control functions
    Carrying out control using a web browser (Web control)
    You can use the computers web browser to change the configuration menu 
    settings for projectors.PROCEDURE
    Right-click on the icon of a projector to be controlled 
    in Grouping view or Detail list view and select 
    Web control.The web browser will open and the Web control 
    window will be displayed.
    Web control lets you set the same details as the configuration menu for the 
    projector. Refer to the Projectors Users Guide for details on the 
    configuration menu.
    TIP
     Some connected projectors may not be equipped with all of the 
    above ports or functions. If you click a button for a port or function 
    that is not available, nothing will happen.
     You can select objects to be controlled and use the control buttons to 
    carry out control operations even when the following are being 
    displayed. 
    s
    For details on each display p.23, 24
    - Group properties
    - Projector properties
    - Warning and Error Projector list (Control operations can only be 
    carried out for projectors with a warning status.)
    12
    TIP
    You can select projectors and right-click on them to select Web 
    control even when the following are being displayed.
     Group properties 
    s
    p.24
     Warning and Error Projector list (Control operations can only be 
    carried out for projectors with a warning status.) 
    s
    p.23 
    						
    							28
    Using the control functions
    Carrying out control using timer settings
    This is useful for carrying out certain control operations such as turning a 
    projectors power on and off at specified times every day or every week.
    Timer settings can be carried out either for a single projector only, or all at 
    once for all projectors in a group.PROCEDURE
    Select Timer - Timer Settings from the Tool 
    menu.
    The following window will be displayed and you can then 
    check the timer setting status.
    The details that can be checked and operations that can be carried out at this 
    time are given below.
    1
    The colours in the lines of the list have the following meanings:
    : Current days timer setting
    : When some of the projectors in the group have timer setting 
    enabled and others have it disabled for the current days timer 
    setting
    : When the current days timer setting is a disabled setting
    : Timer setting for a day other than the current day
    Projectors
    Selects a group or projector to check the status of.
    When a group is selected, the timer setting statuses for 
    all projectors in that group are displayed.
    Date
    Shows the current day in a red box.
    Days for which timer settings have been made are shown 
    in bold.
    Click   or   to switch to the calendar for the 
    previous or next month.
    Timers
    Shows a list of the timer settings.
    [Enabled]
    [Disabled]
    Switches the timer settings that have been selected from 
    the timer list between enabled and disabled.
    [Add]
    Registers new timer settings.
    [Edit]
    Lets you change the timer settings that have been 
    selected from the timer list.
    If a group has been selected for status checking, the 
    settings cannot be changed.
    [Delete]
    Lets you delete timer settings that have been selected 
    from the timer list. 
    						
    							29
    Using the control functions
    fProcedures for new timer settings
    When you click Add, the following window is 
    displayed and the new timer settings are applied.
    At Operation, you can carry out the operations of turning the 
    power on and off and switching the input sources, similarly for 
    the control buttons on the main window. If you set the input 
    source switching, the projectors power will turn on at the timer 
    start time even if it is not on at the time. Because of this, it is not 
    necessary to make two separate timer settings for turning the 
    power on and switching the input source.
    After completing the timer settings, click [OK].
    The timer settings that have been made will be registered and 
    they can be checked in the displayed timer list.
    23
    TIP
    You can enable and disable all of the timer settings that have been 
    registered. Select Timer - Enable or Disable from the Tool 
    menu. 
    						
    All Epson manuals Comments (0)