Eiki Projector Lc X7 User Manual
Have a look at the manual Eiki Projector Lc X7 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 422 Eiki manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
61 Maintenance and Care Check the number of lamp to be replaced on the Lamp Status Display. Loosen a screw on the Lamp Cover. Slide and open the Lamp Cover until it makes a clicking sound. (See the right figure.) 1 3 Loosen two screws and pull out the Lamp to be replaced by grasping handle.4 Turn off the projector, press the Main On/Off Switch to Off and unplug the AC power cord from the AC outlet. Let the projector cool for at least 45 minutes. 2 Replace the Lamp with a new one and tighten two screws. Make sure the Lamp is set properly. 6 Follow these steps to replace the lamp. Put the Lamp Cover back and tighten a screw. 5 7 8 Connect the AC Power Cord to the projector and turn on the projector. Reset the Lamp Replacement Counter. (Refer to section "Resetting the Lamp Counter" on page 62.) NOTE : Do not reset LAMP REPLACEMENT COUNTER when lamp is not replaced. SCREW LAMP COVER SCREWS Make sure which number of lamp needs to be replaced on Lamp Status Display. Figure shows case of replacing LAMP 1. LAMP 2 LAMP 1 CAUTION : DO NOT OPERATE THE PROJECTOR WHILE ANy OF LAMPS IS REMOVED . IT MA y RESULT IN MALFUNCTIONS, FIRE HAZARD, OR OTHER ACCIDENTS . NOTES ON LAMP REPLACEMENT To maintain quality of picture (better balance of color and brightness in entire screen), we recommend replacing both lamps at a time . Lamp Replacement For continued safety, replace with a lamp assembly of the same type. Do not drop the lamp assembly or touch a glass bulb! The glass can shatter and may cause injury. Allow the projector to cool, for at least 45 minutes before you open Lamp Cover. The inside of the projector can become very hot. CAUTION TURN OFF THE UV LAMP BEFORE OPENING THE LAMP COVER. WARNING: When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP 1/2 REPLACE indicator lights orange. Replace the lamp with a new one promptly. The timing when the LAMP 1/2 REPLACE indicators should light is depending on the lamp mode. Indicators LAMP 1 / REPLACE indicators Lamp replacement icon ✔Note: • The Lamp replacement icon will not appear when the Display function is set to “Off” (p.48), or during “Freeze” (p.29).
6 Maintenance and Care ORDER REPLACEMENT LAMP Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the following information to the dealer. ● Model No . of your projector : LC-X7 ● Replacement Lamp Type No . : POA-LMP104 (Service Parts No. 610 337 0262) Resetting the Lamp Counter Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP 1/2 REPLACE indicator stops lighting and the Lamp replacement icon disappears. ✔Note: • Do not reset the Lamp counter without replacing the lamp. Be sure to reset the Lamp counter only after replacing the lamp. Press the MENU button to display the On-Screen Menu. Use the Point 7 8 buttons to move the red frame pointer to the Setting Menu icon Use the Point ed buttons to move the red frame pointer to Lamp counter and then press the SELECT button. A dialog box appears. Select a lamp and the “Lamp replacement counter Reset?” appears. Select [Yes] to continue. 1 2 Lamp counter Select a lamp and the “Lamp replacement counter Reset?” appears. Select [Yes] again to reset the lamp counter. Select [Yes], then another confirmation box appears. Another confirmation dialog box appears and select [Yes] to reset the Lamp counter.3
6 This projector uses a high-pressure lamp which must be handled carefully and properly. Improper handling may result in accidents, injury, or create a fire hazard. ● Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no guarantee of the same lifetime for each lamp. Some lamps may fail or terminate their lifetime in a shorter period of time than other similar lamps. ● If the projector indicates that the lamp should be replaced, i.e., if the LAMP 1/2 REPLACE indicators light up, replace the lamp with a new one IMMEDIATELY after the projector has cooled down. (Follow carefully the instructions in the Lamp Replacement section of this manual.) Continuous use of the lamp with the LAMP 1/2 REPLACE indicators lighted may increase the risk of lamp explosion. ● Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in which the projector and lamp are being used. IF A LAMP EXPLODES, THE FOLLOWING SAFET y PRECAUTIONS SHOULD BE TAKEN . If a lamp explodes, disconnect the projector’s AC plug from the AC outlet immediately. Contact an authorized service station for a checkup of the unit and replacement of the lamp. Additionally, check carefully to ensure that there are no broken shards or pieces of glass around the projector or coming out from the cooling air circulation holes. Any broken shards found should be cleaned up carefully. No one should check the inside of the projector except those who are authorized trained technicians and who are familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who are not appropriately trained to do so, may result in an accident or injury caused by pieces of broken glass. LAMP HANDLING PRECAUTIONS Maintenance and Care
64 Turn off the projector, press the Main On/Off Switch to Off and unplug the AC power cord from the AC outlet before cleaning. Gently wipe the projection lens with a cleaning cloth that contains a small amount of non-abrasive camera lens cleaner, or use a lens cleaning paper or commercially available air blower to clean the lens. Avoid using an excessive amount of cleaner. Abrasive cleaners, solvents, or other harsh chemicals might scratch the surface of the lens. Cleaning the Projector Cabinet Turn off the projector, press the Main On/Off Switch to Off and unplug the AC power cord from the AC outlet before cleaning. Gently wipe the projector body with a soft dry cleaning cloth. When the cabinet is heavily soiled, use a small amount of mild detergent and finish with a soft dry cleaning cloth. Avoid using an excessive amount of cleaner. Abrasive cleaners, solvents, or other harsh chemicals might scratch the surface of the cabinet. When the projector is not in use, put the projector in an appropriate carrying case to protect it from dust and scratches. Cleaning the Projection Lens Maintenance and Care
65 Maintenance and Care The WARNING indicators show the state of the function which protects the projector. Check the state of the WARNING TEMP. indicator and the LAMP indicator to take proper maintenance. Warning Indicators The projector is shut down and the WARNING TEMP. indicator is blinking red. When the temperature inside the projector reaches a certain level, the projector will be automatically shut down to protect the inside of the projector. The LAMP indicator turns red brighter and the WARNING TEMP indicator blinks while the projector is being cooled down. When the projector has cooled down enough (to its normal operating temperature), it can be turned on again by pressing the ON/ STAND-BY button. ✔Note: • The WARNING TEMP. indicator continues to blink even after the temperature inside the projector returns to normal. When the projector is turned on again, the WARNING TEMP. indicator stops blinking. Then check the matters below: – Did you provide appropriate space for the projector to be ventilated? Check the installing condition to see if the air vents of the projector are not blocked. – Has the projector been installed near an Air-Conditioning/ Heating Duct or Vent? Move the installation of the projector away from the duct or vent. – Is the filter clean? Replace the filter with a new one. CAUTION DO NOT LEAVE THE PROJECTOR WITH THE AC POWER CORD CONNECTED UNDER AN ABNORMAL CONDITION. IT MAY RESULT IN FIRE OR ELECTRIC SHOCK. Indicators Indicators WARNING TEMP . blinking red Maintenance and Care The projector is shut down; and the LAMP indicator is lighting and other indicators are blinking. When the projector detects an abnormal condition, it will be automatically shut down to protect the inside of the projector and the LAMP indicator lights on and other indicators blink. In this case, unplug the AC power cord and plug it, and then turn on the projector once again to verify operation. If the projector cannot be turned on and these indicators are still lighting and blinking, unplug the AC power cord and contact the service station. LAMP indicator lights on and other indicators blink .
66 Troubleshooting Before calling your dealer or service center for assistance, check the items below once again. 1. Make sure you have properly connected the projector to peripheral equipment as described \ on pages 20–21. 2. Check the cable connection. Make sure that all computers, video equipment, and power cords are properly connected. 3. Make sure that all power is switched on. 4. If the projector still does not produce an image, restart your computer. 5. If an image still does not appear, disconnect the projector from your computer and check your computer monitor’s display. A problem may be noticed with your graphics controller rather than with the projector. (When you reconnect the projector, be sure to turn the computer and monitor off before you turn on the projector. Turn on equipment in the order of the projector and computer.) 6. If a problem still persists, check the following solutions. Appendix Problem:Solutions No power. – Plug the power cord of the projector into the AC outlet. – Turn the MAIN ON/OFF switch to ON. – Press the ON/STAND-BY Button to ON. – Make sure the READY Indicator lights. – Check the indicators. If the LAMP indicator lights and the other indicators blink, the projector cannot be turned on. (Refer to page 65.) – Check the projection lamp. (Refer to page 61.) PIN code dialog box appears at start-up. – PIN code lock is being set. Enter a PIN code; the “1234” or numbers you have set (see pages 23, 53-54) The initial display is not shown. – Make sure “Off ” or “Countdown Off” are not chosen at Display function. (See “SETTING” section on page 48) The initial display is not same with the default one. – Make sure “User” or “Off” are not chosen at Logo select function. (See “SETTING” section on page 49) When the projector is on and you press the input button, an icon other than the Lamp mode icon appears. – That is the Filter warning icon. Refer to page 56. An icon other than Input mode or Lamp mode icon appears. – That is the Lamp replacement icon or the Filter warning icon. See page 55-56. No image. – Check the connection between your computer or video equipment and the projector. – See if the input signal is correctly output from your computer. Some laptop computers may need to be changed the setting for monitor output when connected to the projector. See your computer’s instruction manual for the setting. – It takes about 20 seconds to display an image after turning on the projector. – See if the selected system is corresponding with your computer or video equipment. – Select correct input source once again through menu operation (see pages 31, 41-42). – Make sure the temperature is not out of Operating Temperature (41˚F–104˚F [5˚C– 40˚C]).
67 appears on the screen – The end of lamp life is approaching. Replace the lamp with a new one promptly. (See page 55) appears on the screen – The filter is out of scroll. Replace the filter cartridge with a new one promptly. (See pages 57-58) The image is out of focus. – Adjust the focus of the projector. – Check Projection Lens to see if it needs cleaning. ✔Note: Moving the projector from a cool temperature location to a warm temperature location may result in moisture condensation on Projection Lens. In such cases, leave the projector OFF and wait until condensation evaporates. – Projecting from excessive slant angle to the screen may cause keystone distortion and partial imperfect focus. The image is not bright enough. –Check if “Contrast” or “Brightness” are adjusted properly. (See page 45) –Check if “Image level” is selected properly. (See pages 38, 42) –Check the Lamp control function. ( See “SETTING” section on page 51) – Check the Lamp 1/2 replace indicators. If it lights, the end of lamp life is approaching. Replace the lamp with a new one promptly. (See page 61) – The image is darker when 1 lamp mode is selected, compared with 2 lamp mode. Check the lamp mode at SETTING section on page 51. The color is strange.–Check the Input signal, color system, video system, or computer system mode. The image is Left/Right reversed.– Check the Ceiling / Rear function. (See pages 40, 44.) The image is Top/Bottom reversed.– Check the Ceiling function. (See pages 40, 44.) The image is distorted or runs off.–Check “PC Adjust” menu or “ Screen” menu and adjust them. Auto PC adjustment function does not work. – Check the Input signal. Auto PC Adjustment function cannot work when 480p, 575p, 720p, 480i, 575i, 1035i, or 1080i is selected or when the digital signal is input into DVI terminal. (See page 35) Some displays are not seen during the operation.– Check the Display function (see page 48). The setting does not remain after turning off power. – Make sure you selected “Store” after adjusting settings. Some settings cannot be stored if not registered with “Store”. Power management function does not work. – Power management function cannot work while “Freeze” function is running or the shutter is closed. Image disappears automatically. – Check the power management function in the Setting. The power management is set to "On" at the factory. Capture function does not work.–Check the connection to see if there is signal. Some menus cannot be selected.–Each of the Video Input and Computer Input has a limit on selectable menus. Appendix
68 WARNING: High voltages are used to operate this projector . Do not attempt to open the cabinet . If problems still persist after following all operating instructions, contact the dealer where you purchased the projector or the service center. Specify the model number and explain about the problem. We will advise you how to obtain service. This symbol on the nameplate means the product is Listed by Under writers Laboratories Inc. It is designed and manufactured to meet rigid U.L. safety standards against risk of fire, casualty, and electrical hazards. The CE Mark is a Directive conformity mark of the European Community (EC). Appendix The power is turned off automatically. – Power management function runs by initial setting. Check “SETTING” section on page 52. You cannot operate with the side control. – The side control is not available If the side control is locked at “Key lock” under “Security” of SETTING section. Please check “SETTING” section on page 53. The Remote Control does not work. –Check the batteries. –Check if the RC sensor is set properly.(See page 52) –Make sure no obstruction is between the projector and remote control. –Make sure you are not too far from the projector when using the remote control. Maximum operating range is 16.4’ (5m). –Make sure that the remote control code conforms to the projector’s code. (See “SETTING” section on page 52.) – Make sure the reset switch in the compartment lid on back of the remote control is set to use position. –Unlock the Key lock function for the remote control. (See page 53) – Wireless remote control does not work when the remote control cable is connected to the projector. (See page 15) Indicators blinks or lights.– Check the status of the projector with referring to “ INDICATORS AND PROJECTOR CONDITION” on pages 72-74. appears on the screen –Your operation is invalid. Operate correctly. Unable to unlock the Logo PIN code lock, Security key lock or Security PIN code lock. –Contact the dealer where you purchased the projector or the service center. Forget the Logo PIN code or Security PIN code. –Contact the dealer where you purchased the projector or the service center.
69 Menu Tree InputRGB (PC analog)Go to System (1)Input 1 Y, Pb/Cb,Pr/Cr Computer Input/Video Input RGB (Scart) RGB (PC digital) RGB (AV HDCP) Input 3 RGBGo to System (1) Go to System (3) Go to System (2)Video S-video Input 2 Go to System (1) InputH-sync freq.V-sync freq. Projector Information Key lock ScreenLanguageLamp mode Power management Security Remote control Quit 0–630–63 Off/On/Film Image AdjustContrastBrightnessColor ✽Tint ✽ RedGreenBlue Sharpness ResetStore Gamma Progressive ✽ 0–630–630–63 0–31 0–15 Image 1Yes / No Quit Off/OnNoise reduction ✽ 0–630–63 ✔Note: •The Menu display varies depending on the input signal. InformationImage Adjust ✽Displayed in grayout in the computer Input. HighMidLow XLow Adj. Color temp. Appendix Colormanagement Auto picture controlOff/L1/L2 HighMidLow Color temp. OffsetRed/Green/Blue Image 10 Color Gamma ListColor M. Menu MidLow Color M. All DelMenu Lamp control Go to System (2) Shutter managementRemote Control 5 - 180 Min PIN code lock Input 4 (For Optional Interface Boards) (For Optional Interface Boards) Go to System (1)
70 Computer Input System (1)Mode 1 Mode 2 Image SelectStandard Real Image 1 Image 10 ScreenNormal True Wide Full screen Digital zoom + Digital zoom - PC AdjustAuto PC adj. Fine sync. Total dots Position H Position V Current mode Clamp Display area - H Display area - V Reset Mode free Store Quit 0–31 Yes/No Mode 1 Mode 10 Quit ✽ System displayed in the System Menu varies depending on the input signal. ✔Note: •The Menu display varies depending on the input signal. SVGA 1 SVGA 2 SVGA 3 Rear Keystone CeilingResetStore On/OffOn/Off CustomH & VScale Position H / VOn/OffH / VCommonReset Video Input System (2)Auto PAL SECAM NTSC NTSC 4.43 PAL-M PAL-N System (3)Auto 1080i 1035i 720p 575p 480p 575i 480i Image SelectStandard Cinema Image 1 Image 10 ScreenNormal Wide Rear Keystone CeilingResetStore On/OffOn/Off CustomH & VScale Position H / VOn/OffH / VCommonReset Reset Reset Appendix Quit Quit Quit Quit