11PJ NETWORK MANAGEROWNER'S MANUAL Addition of the target 1 Select Target Addition from Target menu. The target information registering window appears. 2 Enter target setup information and click Update button. The information set on the target equipment are dis- played on the system information items. 0 When the target equipment is not operating, or it is not the monitoring equipment, the error dialog "Cannot obtain infor-mation" will appear. 3 Click OK to close the window. Repeat the above steps to register for other equipment which is to be managed. Editing the target 1 Select a target name to edit on the status list with right click. 2 Select Target editing on the popup menu. The target information window will appear and edit the contents, then click OK button. 0 The system information cannot be edited. 0 Target editing can be executed by selecting Target editing from Target menu. Deletion of the target 1 Select a target name to delete on the status list with right click. 2 Select Target deletion on the popup menu. The confirmation dialog will appear and click Yes button to execute deleting. 0 Target deletion can be executed by selecting Target deletion from Target menu. 0 It cannot perform the target addition, editing and deletion during the target monitoring. 0 Up to 200 targets can be registered. 0 Up to 255 characters can be used for target name and community. Items Description Name ......................... Enter a management name of the target equipment.IP address ............... Enter IP address of the target equipment.Community ........... Enter a community name in the network. Default name is "public".System information ..... Displays information set on the network equipment Addition of the target
1 Chapter 3 Basic Operation Setting up the warning value PJ Network Manager provides a function to display the alert when the use time of the set- ting item reaches a specified setting time. The available setting items (use time) are depend- ing on the target equipment. 1 Select a target on the status list with right click. 0 When setting multiple targets together, select targets with pressing "Shift" or "Control" key. 2 Select Warning value setting on the popup menu. The setting window will appear as the right figure. 3 Check Warning time check box. The setting items are activated. Select a setting item and click Edit button. Another setting window appears. 4 Enter the threshold value of selected item and then click OK button. The setting window will dis- appear. 5 Set up warning value for remaining items if avail- able and then click OK button. The setting win- dow will disappear. 0 To disable the warning value, clear Warning time check box. 0 When selecting multiple targets, the value set to the lowest target on the status list is displayed as the current setting time. Up to 99,999 hours can be set for the use time. The warning value is stored in the management file. Starting target monitoring 1 Click button on the tool bar to start monitoring the target. 2 PJ Network Manager starts polling the target in a sequential from the top of the status list and displays the results on the status list. (Example of the set up window)
1PJ NETWORK MANAGEROWNER'S MANUAL What's Trap Trap is the event predefined by the SNMP agent. If the predefined event ( "When PJ lamp is off ", "When internal PJ power circuit is failed" etc. ) happens, target sends trap information to the SNMP manager. When happens the alert on the target When happens the alert on the target If the abnormality or connection error happens on the target, PJ Network Manager indi- cates target name, icon and status column item with red color to let you know the abnor- mality. 0 When PJ Network Manager cannot acquire the MIB information of the target equipment, it indi-cates as Connection Error. 0 The interval of target monitoring is according to the setting of Monitoring interval on System default setting from System menu. (+p.17) 0 For the way to give notice of the alert information, refer to Event reception process on System default setting from System menu. (+p.17) When happens the trap event on the target During the target monitoring, if the predefined event (trap) happens on the target equip- ment, the target sends the trap information to PJ Network Manager. This trap information is displayed on the status list. The trap information is set up in the SNMP setting items of the target equipment. Projector has items such as "When PJ lamp is off ", "When the life span of lamp is reached", "When internal PJ power circuit is failed" etc. For further trap information, refer to "SNMP setting" in the separated network owner's manual. 0 For the way to give notice of the trap information, refer to Event reception process on System default setting from System menu. (+p.17)
1 Chapter 3 Basic Operation Displaying all the status information of the target Select a target and click button on the tool bar. The following status window appears and displays all the available status information of the target. 0 The target name and item which have an abnormality or connection error happen-ing are indicated with red. 0 W h e n PJ N e t w o r k M a n a g e r c a n n o t acquire the value of column information, "---" is displayed. Stopping monitoring the target To stop monitoring the target, click button again on the tool bar. 0 The projectors setting different network passwords cannot be set to the same group. It is necessary for the projectors in the same group to set to the same password. 0 The above procedure can perform by selecting Target display from Display menu. Setting the target group The target group can be set up by the procedure below. When you set a command in the same group, you set it. 1 Select targets which you want to set from the status list. Select Group setting from Target menu, the dialog box will appear as the below figure. 2 Select a group, and then click OK button. 0 "---" will not set the group.
1PJ NETWORK MANAGEROWNER'S MANUAL Setting up the password of Telnet The password of telnet can be set up by the procedure below. It is necessary to make a password, same as the network password. 1 Select a target which you want to set up the password of telnet from the status list. You can select multiple targets. 2 Select Telnet setting from Target menu, Telnet setting dialog box will appear as the below figure. Set a password and click OK button. When multiple targets are selected, all the selected targets are set as the same password. Setting up the password of Telnet 0 The initial setting is "0000". Setting commands batch processing for multiple targets The commands batch processing for multiple targets can be set up by the procedure below. 1 Select a target belonging to the batch processing group which you want to set, and select Commands batch processing from Target menu. Commands batch processing dialog box will appear as the below figure. 2 Select a command which you want to set, click Edit button. Parameter editing dia- log box will appear. Select a parameter, and then click OK button. The check box of Commands batch processing dialog box will be checked. 3 Click OK button. The commands are carried out to all the targets of the same group. 0 The commands also work for the target which is not set to a group.
1 Chapter 3 Basic Operation Commands batch processing : Available CommandItems Description Power ON/OFF ......................... Sets up the Power ON or Power OFF.Input,Source .............................. Sets up the Input and Source. Selects Input and Source.Screen ....................................... Sets up the screen size. Resizes the picture screen.Background ............................... Sets up the background. Selects the background screen for when no input signal is detected.Display ........................................ Sets up the Display. Decides whether to display On-Screen Displays or not.Shutter(No show) .................... Sets up the Shutter (No show). Sets black out the image.Lamp control ............................. Sets up the Lamp control. Changes brightness of the screen.Fan control ................................. Sets up the Fan control. Chooses the running speed of cooling fans. Setting timer for targets The timer information for targets can be set up by the procedure below. 1 Choose a target which you want to set the timer. 2 Select Timer setting from Target menu. Timer selection dialog box will appear as the below figure. Check in a check box of an event to carry out. 3 When you want to add events, click Add button. Input timer informations in Timer set- ting dialog box, and click OK button. 4 Click OK button of Timer selection dialog box, timers are set to the selected target. When selecting multiple targets, timers are set to all the selected targets. TimerItems Description Execution date ......................... Sets up the Timer execution date. (everyday or a day)Execution time .......................... Sets up the Timer execution time. (hh:mm:ss)Action ....................................... Sets up the events.
1PJ NETWORK MANAGEROWNER'S MANUAL Setting up default setting The monitoring information and e-mail information can be set up by the procedure below. 1 Select System default setting from System menu. The setting window will appear. 2 Switch by clicking Monitoring information or E-mail information tab for each setting. Monitoring informationItems Description Monitoring interval ................ Sets up the interval of the polling in minute unit. (1 to 99 minutes can be set)Temperature unit ..................... Sets up the display temperature unit Centigrade or Fahrenheit.Event reception process.......... Sets up the treatment when the event (ALERT, TRAP, SYSERR) happens on the target. For further information, refer to the item "About event treatment" (+p.26). p Sound warning alarm p Send e-mail p Display warning dialog Monitoring information Setting up default setting
1 Chapter 3 Basic Operation E-mail informationItems Description SMTP server ..................... Sets up the IP address of SMTP mail server or server host name.Administrator'smail address ...................... Sets up the e-mail address of administratorDestination mail address ................................ Sets up the destination mail address when the event (ALERT, TRAP, SYSERR) happens on the target. The mail address entering window appears when clicking Add button. E-mail information 0 If Send e-mail check box of Event reception process on Monitoring information is un-checked, the alert e-mail will not be sent even if you set up the e-mail address. 0 Up to 10 addresses can be set up for the destination mail address.0 For the contents of the mail, refer to item "About event treatment" (+p.26).
1PJ NETWORK MANAGEROWNER'S MANUAL Customizing the status list Changing the status column indication 1 Select Column selection from System menu. The col- umn selection window will appear. 2 On the window, check the column name to be indi- cated on the status list. 0 The mark [*] next to the column name indicates aler t item. 3 To change the order of the display column on the status list, select a column you intend to change the order and click To up or To down button. 4 Click OK to close setting. 0 When specifying the column width by numeric value, enter number (0 to 9999) onto "Column width" text box. Column Description *Target name ............................Name of the network equipment*Group ...........................................Group name*Connect ......................................Status of connection to the network (Connected, Un-connected)*Drive time .................................Accumulated use time of the equipment*Power status ............................ Power status of the equipment (Normal(Power-on), Normal(Standby), Power Management, Power failure, lamp failure, etc.)*Input status ..............................Input signal status (Signal, No signal, Signal interrupted)*Inside Temperature A status ....................................Status of inside temperature A (Normal, Warning, Error)*Inside Temperature B status ....................................Status of inside temperature B (Normal, Warning, Error)*Inside Temperature C status ....................................Status of inside temperature C (Normal, Error)*External Temperature status.........................................Status of external temperature (Normal, Warning, Error)*Lamp1 status ..........................Status of Lamp1 (Off, On, Error, Replace)*Lamp2 status ..........................Status of Lamp2 (Off, On, Error, Replace)*Lamp3 status ..........................Status of Lamp3 (Off, On, Error, Replace)*Lamp4 status ..........................Status of Lamp4 (Off, On, Error, Replace)*Lamp1 time..............................Used time of Lamp1*Lamp2 time..............................Used time of Lamp2*Lamp3 time..............................Used time of Lamp3*Lamp4 time..............................Used time of Lamp4*Filter status ...............................Status of airfilter (Normal, Clogged)*Option Box filter status ............................Status of option box filter (Normal, Error, Clogged)*Filter time ..................................Use time of airfilter*Option Box filter time ................................Use time of option box filter 0 The values in parentheses are typical value and they differ depending on the connected equipment. 0 The [*] next to the column name indicates alert items. Customizing the status list Specifies col-umn width
0 Chapter 3 Basic Operation Column Description *Error info. ...................................Error information (Not available for the projector)IP address ....................................IP address of the network equipmentCommunity ................................Community name of the network equipment (public)Introduction date*1 ...............Date of the network equipment installedTimer ...............................................Timer informationProduct info. ..............................Name of the network equipment System name ............................System name of the network equipment (Proj_05)Contact ..........................................Contact information of the network equipmentLocation ........................................Installed location of the network equipmentInput signal ................................Information of the input mode (Input1, Input2, etc.)Input select ................................Information of the input source (RGB, VIDEO, S-VIDEO, NETWORK, etc.)Network status.........................Condition of the network mode (Off line, Network Viewer, Network Capture)Audio system ............................Displays audio system mode (NORMAL, PERSONAL, MUSIC, TALK)Volume ..........................................Sound Volume of the network equipment Treble ..............................................Sound treble of the network equipmentBass ..................................................Sound bass of the network equipmentBalance ..........................................Sound balance of the network equipment Mute ................................................Sound mute status of the network equipment (ON, OFF)Power management ............ Power management status of the network equipment (OFF, READY, SHUTDOWN)Monitor out ................................Monitor out status of the network equipment (ON, OFF)Shutter ...........................................Shutter status of the network equipment (OFF, High-Contrast, Normal)Shutter management .........Shutter management status of the network equipment (Shutdown)Fan control ..................................Fan control status of the network equipment (Normal, Maximum, OFF, On1, etc. )Inside Temperature A ..........Displays inside temperature A of the equipment (in Centigrade or Fahrenheit)Inside Temperature B ..........Displays inside temperature B of the equipment (in Centigrade or Fahrenheit)Inside Temperature C ..........Displays inside temperature C of the equipment (in Centigrade or Fahrenheit)External Temperature .........Displays external temperature of the equipment (in Centigrade or Fahrenheit)Lamp mode ................................Displays lamp mode (1: 1-lamp mode, 2: 2-lamp mode, 4: 4-lamp mode, etc.)Lamp control .............................Displays lamp control mode (Auto, Normal, Eco, etc.)Model name ..............................Model name of the network equipment *1 Set up the installed date when the PJ Network Manager is newly introduced. 0 There are some un-available columns depending on the products. The value of un-available col -umn is displayed in blank or with "---".