    11PJ NETWORK MANAGEROWNER'S MANUAL
    
    Addition of the target
    1  Select Target  Addition  from Target  menu.  The  target 
    information registering window appears.
    2  Enter  target  setup  information  and  click Update  button. 
    The  information  set  on  the  target  equipment  are  dis-
    played on the system information items.
    0   
    When  the  target  equipment  is  not  operating,  or  it  is  not  the monitoring equipment, the error dialog "Cannot obtain  infor-mation" will appear.
    3   Click OK  to  close  the  window.  Repeat  the  above  steps  to  register  for  other  equipment 
    which is to be managed. 
    Editing the target
    1  Select a target name to edit on the status list with right click.
    2  Select Target  editing  on  the  popup  menu. The  target  information  window  will  appear 
    and edit the contents, then click OK button.
    0 The system information cannot be edited.
    0 Target editing can be executed by selecting Target editing from Target menu.
    Deletion of the target
    1 Select a target name to delete on the status list with right click.
    2  Select Target  deletion on  the  popup  menu.  The  confirmation  dialog  will  appear  and 
    click Yes button to execute deleting.
    0 Target deletion can be executed by selecting Target deletion from Target menu.
    0  It cannot perform the target addition, editing and deletion during the target monitoring.
    0 Up to 200 targets can be registered.
    0  
    Up to 255 characters can be used for target name and community.
    Items  Description
    Name .........................  
    Enter a management name of the target equipment.IP address ...............  
    Enter IP address of the target equipment.Community  ...........  
    Enter a community name in the network. Default name is "public".System information  .....  
    Displays information set on the network equipment
    Addition of the target 
    						
    							
    1
    
    Chapter 3 Basic Operation
    
    Setting up the warning value
    PJ  Network  Manager  provides  a  function  to 
    display  the  alert  when  the  use  time  of  the  set-
    ting  item  reaches  a  specified  setting  time. The 
    available  setting  items  (use  time)  are  depend-
    ing on the target equipment.
    1  Select a target on the status list with right click.
    0  
    When  setting  multiple  targets  together,  select targets with pressing "Shift" or "Control" key.
    2   Select Warning value setting on the popup 
    menu.  The  setting  window  will  appear  as 
    the right figure.
    3  Check Warning  time  check  box. The  setting 
    items  are  activated.  Select  a  setting  item  and  click 
    Edit button. Another setting window appears.
    4  Enter  the  threshold  value  of  selected  item  and 
    then click OK button. The setting window will dis-
    appear.
    5  Set  up  warning  value  for  remaining  items  if  avail-
    able  and  then  click OK  button.  The  setting  win-
    dow will disappear.
    0 To disable the warning value, clear Warning time check box.
    0   
    When selecting multiple targets, the value set to the lowest target on the status list is displayed as the current setting time. Up to 99,999 hours can be set for the use time. The warning value is stored in the management file.
    Starting target monitoring
    1 Click  button on the tool bar to start monitoring the target.
    2   PJ  Network  Manager  starts  polling  the  target  in  a  sequential  from  the  top  of  the  status 
    list and displays the results on the status list.
    (Example of the set up window) 
    						
    							
    1PJ NETWORK MANAGEROWNER'S MANUAL
    
    What's Trap
    Trap is the event predefined by the SNMP agent. If the predefined event ( "When PJ lamp is 
    off ",  "When  internal  PJ  power  circuit  is  failed"  etc.  )  happens,  target  sends  trap  information 
    to the SNMP manager.
    When happens the alert on the target
    When happens the alert on the target
    If  the  abnormality  or  connection  error  happens  on  the  target,  PJ  Network  Manager  indi-
    cates target name, icon and status column item with red color to let you know the abnor-
    mality.
    0  
    When  PJ  Network  Manager  cannot  acquire  the  MIB  information  of  the  target  equipment,  it  indi-cates as Connection Error.
    0   
    The  interval  of  target  monitoring  is  according  to  the  setting  of Monitoring  interval  on System default setting from System menu. (+p.17)
    0   For  the  way  to  give  notice  of  the  alert  information,  refer  to Event  reception  process  on System default setting from System menu. (+p.17)
    When happens the trap event on the target
    During  the  target  monitoring,  if  the  predefined  event  (trap)  happens  on  the  target  equip-
    ment, the target sends the trap information to PJ Network Manager. This trap information is 
    displayed on the status list.
    The trap information is set up in the SNMP setting items of the target equipment. Projector 
    has  items  such  as  "When  PJ  lamp  is  off ",  "When  the  life  span  of  lamp  is  reached",  "When 
    internal PJ power circuit is failed" etc. For further trap information, refer to "SNMP setting" in 
    the separated network owner's manual.
    0   For  the  way  to  give  notice  of  the  trap  information,  refer  to Event  reception  process  on System default setting from System menu. (+p.17) 
    						
    							
    1
    
    Chapter 3 Basic Operation
    
    Displaying all the status information of the target
    Select  a  target  and  click  button  on  the  tool  bar. The  following  status  window  appears 
    and displays all the available status information of the target.
    0  
    The target name and item which have an abnormality or connection error happen-ing are indicated with red.
    0   
    W h e n   PJ   N e t w o r k   M a n a g e r   c a n n o t acquire  the  value  of  column  information,  "---"  is displayed.
    Stopping monitoring the target
    To stop monitoring the target, click  button again on the tool bar.
    0   The  projectors  setting  different  network  passwords  cannot  be  set  to  the  same  group.  It  is necessary for the projectors in the same group to set to the same password.
    0  
    The above procedure can perform by selecting Target display from Display menu.
    Setting the target group
    The target group can be set up by the procedure below. When you set a command in the 
    same group, you set it.
    1   Select  targets  which  you  want  to  set  from  the  status  list.  Select Group  setting  from 
    Target menu, the dialog box will appear as the below figure.
    2  Select a group, and then click OK button.
    0   "---" will not set the group. 
    						
    							
    1PJ NETWORK MANAGEROWNER'S MANUAL
    
    Setting up the password of Telnet
    The  password  of  telnet  can  be  set  up  by  the  procedure  below.  It  is  necessary  to  make  a 
    password, same as the network password.
    1  Select a target which you want to set up the password of telnet from the status list. You 
    can select multiple targets.
    2  Select Telnet  setting  from Target  menu, Telnet  setting  dialog  box  will  appear  as  the 
    below figure. Set a password and click OK button. When multiple targets are selected, all 
    the selected targets are set as the same password.
    Setting up the password of Telnet
    0   
    The initial setting is "0000".
    Setting commands batch processing for multiple targets
    The  commands  batch  processing  for  multiple  targets  can  be  set  up  by  the  procedure 
    below.
    1   Select  a  target  belonging  to  the  batch  processing  group  which  you  want  to  set,  and 
    select Commands  batch  processing  from Target  menu. Commands  batch  processing 
    dialog box will appear as the below figure.
    2  Select  a  command  which  you  want  to  set,  click Edit  button. Parameter  editing  dia-
    log  box  will  appear.  Select  a  parameter,  and  then  click OK  button.  The  check  box  of 
    Commands batch processing dialog box will be checked.
    3  Click OK button. The commands are carried out to all the targets of the same group.
    0  The commands also work for the target which is not set to a group. 
    						
    							
    1
    
    Chapter 3 Basic Operation
    
    Commands batch processing : Available CommandItems Description
    Power ON/OFF .........................  
    Sets up the Power ON or Power OFF.Input,Source .............................. Sets up the Input and Source. Selects Input and Source.Screen  .......................................  
    Sets up the screen size. Resizes the picture screen.Background ............................... Sets up the background. Selects the background screen for when no input signal is detected.Display ........................................ Sets up the Display. Decides whether to display On-Screen Displays or not.Shutter(No show)  .................... Sets up the Shutter (No show). Sets black out the image.Lamp control ............................. Sets up the Lamp control. Changes brightness of the screen.Fan control ................................. Sets up the Fan control. Chooses the running speed of cooling fans.
    Setting timer for targets
    The timer information for targets can be set up by the procedure below.
    1   Choose a target which you want to set the timer.
    2  Select Timer  setting  from Target  menu. Timer  selection  dialog  box  will  appear  as  the 
    below figure. Check in a check box of an event to carry out.
    3  
    When  you  want  to  add  events, click Add  button. Input  timer  informations  in Timer  set-
    ting dialog box, and click OK button.
    4  Click OK  button  of Timer  selection  dialog  box,  timers  are  set  to  the  selected  target. 
    When selecting multiple targets, timers are set to all the selected targets.
    TimerItems  Description
    Execution date .........................  
    Sets up the Timer execution date.  (everyday or a day)Execution time .......................... Sets up the Timer execution time. (hh:mm:ss)Action  .......................................  
    Sets up the events. 
    						
    							
    1PJ NETWORK MANAGEROWNER'S MANUAL
    
    Setting up default setting
    The monitoring information and e-mail information can be set up by the procedure below.
    1  Select System default setting from System menu. The setting window will appear.
    2  Switch by clicking Monitoring information or E-mail information tab for each setting.
    Monitoring informationItems  Description
    Monitoring interval ................  
    Sets up the interval of the polling in minute unit. (1 to 99 minutes can be set)Temperature unit ..................... Sets up the display temperature unit Centigrade or Fahrenheit.Event reception process..........  
    Sets up the treatment when the event (ALERT, TRAP, SYSERR) happens on the target. For further information, refer to the item "About event treatment" (+p.26). p Sound warning alarm p Send e-mail p Display warning dialog
    Monitoring information
    Setting up default setting 
    						
    							
    1
    
    Chapter 3 Basic Operation
    
    E-mail informationItems Description
    SMTP server .....................  
    Sets up the IP address of SMTP mail server or server host name.Administrator'smail address ...................... Sets up the e-mail address of administratorDestination mail address  ................................  
    Sets up the destination mail address when the event (ALERT, TRAP, SYSERR) happens on the target. The mail address entering window appears when clicking Add button.
    E-mail information
    0  If Send  e-mail  check  box  of Event  reception  process  on Monitoring  information  is  un-checked, the alert e-mail will not be sent even if you set up the e-mail address.
    0  
    Up to 10 addresses can be set up for the destination mail address.0  For the contents of the mail, refer to item "About event treatment" (+p.26). 
    						
    							
    1PJ NETWORK MANAGEROWNER'S MANUAL
    
    Customizing the status list
    Changing the status column indication
    1  Select Column selection from System menu. The col-
    umn selection window will appear.
    2  On  the  window,  check  the  column  name  to  be  indi-
    cated on the status list.
    0   
    The  mark  [*]  next  to  the  column  name  indicates  aler t item.
    3  
    To  change  the  order  of  the  display  column  on  the 
    status  list,  select  a  column  you  intend  to  change  the 
    order and click To up or To down button.
    4 Click OK to close setting.
    0   When specifying the column width by numeric value, enter number (0 to 9999) onto "Column width" text box.
    Column  Description
    *Target name ............................Name of the network equipment*Group  ...........................................Group name*Connect  ......................................Status of connection to the network (Connected, Un-connected)*Drive time  .................................Accumulated use time of the equipment*Power status  ............................  
    Power status of the equipment (Normal(Power-on), Normal(Standby), Power Management, Power failure, lamp failure, etc.)*Input status  ..............................Input signal status (Signal, No signal, Signal interrupted)*Inside Temperature
       A status  ....................................Status of inside temperature A (Normal, Warning, Error)*Inside Temperature
       B status  ....................................Status of inside temperature B (Normal, Warning, Error)*Inside Temperature
       C status  ....................................Status of inside temperature C (Normal, Error)*External Temperature
        status.........................................Status of external temperature  (Normal, Warning, Error)*Lamp1 status  ..........................Status of Lamp1 (Off, On, Error, Replace)*Lamp2 status  ..........................Status of Lamp2 (Off, On, Error, Replace)*Lamp3 status  ..........................Status of Lamp3 (Off, On, Error, Replace)*Lamp4 status  ..........................Status of Lamp4 (Off, On, Error, Replace)*Lamp1 time..............................Used time of Lamp1*Lamp2 time..............................Used time of Lamp2*Lamp3 time..............................Used time of Lamp3*Lamp4 time..............................Used time of Lamp4*Filter status  ...............................Status of airfilter (Normal, Clogged)*Option Box
      filter status  ............................Status of option box filter (Normal, Error, Clogged)*Filter time  ..................................Use time of airfilter*Option Box
      filter time  ................................Use time of option box filter
    0   The values in parentheses are typical value and they differ depending on the connected equipment.
    0   The [*] next to the column name indicates alert items.
    Customizing the status list
    Specifies col-umn width 
    						
    							
    0
    
    Chapter 3 Basic Operation
    
    Column Description
    *Error info. ...................................Error information (Not available for the projector)IP address  ....................................IP address of the network equipmentCommunity  ................................Community name of the network equipment (public)Introduction date*1 ...............Date of the network equipment installedTimer  ...............................................Timer informationProduct info.  ..............................Name of the network equipment System name  ............................System name of the network equipment (Proj_05)Contact  ..........................................Contact information of the network equipmentLocation  ........................................Installed location of the network equipmentInput signal  ................................Information of the input mode (Input1, Input2, etc.)Input select  ................................Information of the input source (RGB, VIDEO, S-VIDEO, NETWORK, etc.)Network status.........................Condition of the network mode (Off line, Network Viewer, Network Capture)Audio system  ............................Displays audio system mode (NORMAL, PERSONAL, MUSIC, TALK)Volume  ..........................................Sound Volume of the network equipment Treble  ..............................................Sound treble of the network equipmentBass  ..................................................Sound bass of the network equipmentBalance  ..........................................Sound balance of the network equipment Mute  ................................................Sound mute status of the network equipment (ON, OFF)Power management  ............  
    Power management status of the network equipment (OFF, READY, SHUTDOWN)Monitor out  ................................Monitor out status of the network equipment (ON, OFF)Shutter  ...........................................Shutter status of the network equipment (OFF, High-Contrast, Normal)Shutter management  .........Shutter management status of the network equipment (Shutdown)Fan control  ..................................Fan control status of the network equipment (Normal, Maximum, OFF, On1, etc. )Inside Temperature A  ..........Displays inside temperature A of the equipment (in Centigrade or Fahrenheit)Inside Temperature B  ..........Displays inside temperature B of the equipment (in Centigrade or Fahrenheit)Inside Temperature C  ..........Displays inside temperature C of the equipment (in Centigrade or Fahrenheit)External Temperature  .........Displays external temperature of the equipment (in Centigrade or Fahrenheit)Lamp mode  ................................Displays lamp mode (1: 1-lamp mode, 2: 2-lamp mode, 4: 4-lamp mode, etc.)Lamp control  .............................Displays lamp control mode (Auto, Normal, Eco, etc.)Model name  ..............................Model name of the network equipment
    *1 Set up the installed date when the PJ Network Manager is newly introduced.
    0      There  are  some  un-available  columns  depending  on  the  products. The  value  of  un-available  col
    -umn is displayed in blank or with "---". 
    						