    Maintenance Indicators
    ■The warning lights on the projector indicate problems inside the projector.
    ■If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
    red, and the projector will enter the standby mode. After the projector has entered the standby
    mode, follow the procedures given below.
    About the temperature warning indicator
    If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
    “
    ” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will
    turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and
    then the projector will enter the standby mode. After “
    ” appears, ensure you perform the measures
    described on page 70.
    About the lamp indicator
    “Change The Lamp. (LAMP 2)” is displayed when the remain-
    ing life of the lamp 2 becomes 5% or less.
    ■When the remaining lamp life becomes 5% or less, “
    ” (yellow) and “Change The Lamp. (LAMP 1/
    2)” will be displayed on the screen.
    ■When the percentage becomes 0%, it will change to “
    ” (red), the lamp will automatically turn off. At
    this time, the lamp indicator will illuminate in red.
    If you try to turn on the projector a fourth time without replacing the lamp, the lamp whose life is 0%
    will not light up.
    Power indicator
    Lamp (1, 2) indicators
    Temperature warning indicator
    Maintenance Indicators
    Indicators on the Projector
    Green on
    Red on
    Green blinks
    Red blinks
    Green on
    Green blinks
    Red on
    Off
    Red on Power indicator
    Lamp (1, 2)
    indicators
    Temperature
    warning indicato
    r
    Normal (Standby)
    Normal (Power on)
    Abnormal (See page 70.)
    Normal (Cooling)
    Normal
    The lamp is warming up.
    The lamp is shut down abnormally or requires to be changed. (See page 70.)
    Normal
    The internal temperature is abnormally high. (See page 70.) 
    						
    							70
    Maintenance indicator
    Problem
    Cause Possible solution
    Temperature
    warning
    indicatorNormalAbnormal
    OffRed on
    (Standby)The internal
    temperature is
    abnormally high. Abnormal
    • Blocked air intake•Relocate the projector to an area
    with proper ventilation. (See page
    10.)
    •Cooling fan break-
    down
    •Internal circuit failure
    •Clogged air intake
    •Clogged dust filter•Take the projector to your nearest
    EIKI Authorized Dealer or Service
    Center for repair.
    •Clean the air vents and the dust
    filter. (See page 67.)
    Lamp (1, 2)
    indicators
    Red on
    (Standby)The lamp does
    not illuminate.•Burnt-out lamp
    •Lamp circuit failure•Carefully replace the lamp. (See
    page 72.)
    •Take the projector to your nearest
    EIKI Authorized Dealer or Service
    Center for repair.
    •Please exercise care when
    replacing the lamp.
    Red on
    Time to change
    the lamp.•Remaining lamp life
    becomes 5% or less. Green on
    Green blinks
    when the lamp
    is warming up.
    Info
    •If the temperature warning indicator blinks and the projector enters the standby mode, the temperature
    warning indicator starts to illuminate. Check whether any of the ventilation holes are blocked (see page 10)
    and then try turning the power back on. Wait until the projector has cooled down completely before plugging
    in the power cord and turning the power back on. (At least 10 minutes.)
    •If the power is turned off for a brief moment due to power outage or some other cause while using the
    projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red
    and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power
    cord in the AC outlet and then turn the power on again.
    •The cooling fan keeps the internal temperature of the projector constant and this function is controlled
    automatically. The sound of the cooling fan may change during operation because the fan speed may
    change and this is not a malfunction.
    The lamp does
    not illuminate.•The lamp is shut
    down abnormally.•Disconnect the power cord from
    the AC outlet, and then connect it
    again.
    Power
    indicatorRed on/
    Green onGreen
    blinksThe power
    indicator blinks in
    green when the
    projector is on.• •• •
    •The filter cover is
    open.
    • •• •
    •The lens cover is
    open.• •• •
    •Securely install the filter cover or
    lens cover.
    • •• •
    •If the power indicator blinks even
    when the filter cover or lens cover
    is securely installed, contact your
    nearest EIKI Authorized Dealer or
    Service Center for advice.
    Maintenance Indicators 
    						
    							71
    Regarding the Lamp
    U.S.A. ONLY
    Lamp
    ■It is recommended that the lamp unit  (sold separately)  be replaced when the remaining lamp life
    becomes 5% or less, or when you notice a significant deterioration in the picture and color quality.
    The lamp life (percentage) can be checked with the on-screen display. See page  65.
    ■ Purchase a replacement lamp unit of type AH-55001 from your place of purchase, nearest EIKI
    Authorized Dealer or Service Center.
    Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
    www.lamprecycle.org or 1-800-242-3454
    Caution Concerning the Lamp
    ■ This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp
    failure can be attributed to numerous sources such as: excessive shock, \
    improper cooling, surface
    scratches or deterioration of the lamp due to a lapse of usage time.
    The period of time up to failure largely varies depending on the individ\
    ual lamp and/or the condition
    and the frequency of use. It is important to note that failure can often\
     result in the bulb cracking.
    ■ When the lamp indicator and on-screen display icon are illuminated, it i\
    s recommended that the
    lamp be replaced with a new one immediately, even if the lamp appears to be operating normally.
    ■ Should the lamp break, the glass particles may spread inside the lamp ca\
    ge or gas contained in the
    lamp may be vented into the room from the exhaust vent. Because the gas \
    in this lamp includes
    mercury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In
    case of exposure to the gas, consult a doctor as soon as possible.
    ■ Should the lamp break, there is also a possibility that glass particles \
    may spread inside of the
    projector. In such a case, it is recommended you contact your nearest EIKI Authorized Dealer or
    Service Center to assure safe operation.
    Replacing the Lamp
    Caution
    •Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn
    or injury.
    • W ait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool
    before removing the lamp unit.
    ■ Carefully change the lamp by following the instructions described in thi\
    s section. *If you wish, you
    may have the lamp replaced at your nearest EIKI Authorized Dealer or Service Center.
    * If the new lamp does not illuminate after replacement, take your projector to the nearest EIKI Authorized
    Dealer or Service Center for repair. 
    						
    							72
    Removing and Installing
    the Lamp Unit
    Warning!
    •Do not remove the lamp unit from the pro-
    jector right after use. The lamp and parts
    around the lamp will be very hot and may
    cause burn or injury.
    Info
    •Make sure the lamp unit is removed using
    the handle. Make sure the glass surface of
    the lamp unit or the inside of the projector
    are not touched.
    • To  avoid injury to yourself and damage to
    the lamp, make sure you carefully follow
    the steps below.
    • Do not loosen other screws except for the
    lamp unit cover and lamp unit.
    1Press  STANDBY-ON  on the
    projector or on  the remote con-
    trol to put the  projector into
    standby mode.
    • Disconnect the power cord and unplug
    the power cord from the AC socket after
    the cooling fan stops.
    • The cooling fan may continue to run for
    a while even after the power cord is re-
    moved.
    • Leave the lamp until it has fully cooled
    down (about 1 hour).
    2Remove the lamp unit cover.
    •Loosen the user service screw ( 1) that
    secures the lamp unit cover. Remove the
    lamp unit cover to slide it in the direc-
    tion of the arrow ( 2).
    STANDBY-ON button
    Po wer cord
    1
    2
    User service screw
    Optional
    accessoryLamp unit
    AH-55001
    Regarding the Lamp 
    						
    							73
    3Remove the lamp unit.
    •Loosen the securing screws (two for
    each lamp) from the lamp unit. Hold the
    lamp unit by the handle and pull it in the
    direction of the arrow. At this time, keep
    the lamp unit horizontal and do not tilt it.
    4Insert the new lamp unit.
    •Fully insert the lamp unit into the lamp
    unit compartment. Press the handles
    back to their positions, and tighten the
    securing screws.
    5Replace the lamp unit cover.
    •Slide the lamp unit cover to the position
    where the indicator “
    | || |
    |” of the lamp cover
    unit and the “
    \ \\ \
    \” of the projector will meet
    to close the cover. Then tighten the user
    service screw to secure the lamp unit
    cover.
    Info
    •If the lamp unit and lamp unit cover are not
    correctly installed, the power will not turn
    on, even if the power cord is connected to
    the projector.
    Securing screws
    Handle
    AH-55001
    Compartment
    for 
    Lamp 1Compartment
    for 
    Lamp 2
    User service screw 
    						
    							74
    Resetting the Lamp Timer
    Reset the lamp timer after replacing the lamp.
    Info
    •Make sure to reset the lamp timer only
    when replacing the lamp. If you reset the
    lamp timer and continue to use the same
    lamp, this may cause the lamp to become
    damaged or explode.
    1Connect the power cord.
    •Plug the power cord into the AC socket
    of the projector.
    2Reset the lamp timer.
    For Lamp 1
    • When you reset the timer, while simul-
    taneously holding down  \, "  and
    ENTER , press  STANDBY-ON  on the
    projector.
    • “LAMP1 0000H” is displayed, indicating
    that the lamp timer is reset.
    For Lamp 2
    • When you reset the timer, while simul-
    taneously holding down   |, "  and
    ENTER ,  press  STANDBY-ON  on the
    projector.
    • “LAMP2 0000H” is displayed, indicating
    that the lamp timer is reset.
    Po wer cord ENTER button
    \
     , " , | buttons
    STANDBY-ON button
    Regarding the Lamp 
    						
    							75
    Computer Compatibility Chart
    •Multiple signal support
    Horizontal Frequency: 15–126 kHz
    Vertical Frequency: 43–200 Hz
    Computer
    PC/
    MAC/
    WSHorizontal 
    Frequency
    (kHz)Vertical 
    Frequency
    (Hz)
    VGA
    PC
    PC
    SVGA
    XGA
    VESA 
    StandardResolution
    640 
    × 350
    1152 
    × 864 1280 
    × 720
    1280 
    × 768
    1280 
    × 800
    1360 
    × 768
    1366 
    × 768
    1152 
    × 882
    1280 
    ×1024
    1400 
    ×1050 720 
    × 350
    640 
    × 400
    720 
    × 400
    640 
    × 480
    800 
    × 600
    1024 
    × 768Display
    Upscale 27.0 60
    27.0 60
    27.0 60
    60 31.5 70
    31.5 70
    31.5
    70
    31.5
    60
    34.7
    70
    37.9
    72
    37.5
    75
    43.3
    85
    48.0
    90
    53.0
    100
    63.6
    120
    79.5
    150
    81.3
    160
    100.4 200
    31.3 50
    35.2 56
    37.9 60
    46.6 70
    48.1 72
    46.9 75
    53.7 85
    57.0 90DVI
    Support
    64.5 101
    76.2 120
    95.6 150
    101.9 160
    127.4 200
    96.8 120 31.5 70
    37.9 85
    37.9
    27.085
    37.9
    85
    26.2
    50
    Advanced 
    Intelligent 
    CompressionTrue
    Advanced 
    Intelligent 
    Compression 55.0 60
    67.5 75
    76.6 80
    77.1 85
    65.9 72 54.5 60
    67.4 74
    64.0 60
    1600 
    ×1200 SXGA WXGA
    SXGA+
    UXGA91.1 85 80.0 75 78.9 74 74.6 70
    81.3 65
    90.0 72
    93.8 75
    106.3 8575.0 60 107.2 100
    64.0 60
    87.5 70
    MAC 16
    MAC 21
    HP (WS)
    WS MAC 13
    MAC 19
    PC (WS)
    SUN (WS)
    Intelligent 
    Compression
    Upscale 640 
    × 480
    832 × 62435.0
    1152 
    × 870
    68.767
    60.2
    1280 ×102478.1 72
    60.0 60 1024 
    × 768
    1280 
    × 960 VGA
    SVGA
    SXGA
    SXGAXGA75
    85.9 85
    1152 
    × 90061.8 66
    71.7 76 49.7 75
    75 90.2 100 66.2 70
    64.9 72 45.0 60
    47.7 60
    47.8 60 47.8 60
    62.8 75
    113.3 14035.5 43
    40.3 50
    48.4 60
    58.1 72
    68.7 85 60.0 75
    72.9 90
    77.0 95
    80.8 100 56.5 70
    HDMI
    SupportPC/
    MAC/
    WSHorizontal 
    Frequency
    (kHz)Vertical 
    Frequency
    (Hz)VESA 
    StandardResolution DisplayDVI
    SupportHDMI
    Support
    1280 
    × 80049.7 60
    65.3 60
    The following is a list of modes that conform to VESA.  However, this projector supports other signals
    that are not VESA standards.
    The table below lists signal codes that are compatible with the projector. When the images are distorted or
    cannot be projected, adjust the output signal of your computer and so forth while referring to the table below.
    Pixel Clock: 12–230 MHz
    Sync signal: Compatible with TTL level
    •Compatible with sync on green signal 
    						
    							76
    Note
    •This projector may not be able to display images from notebook computers in simultaneous (CRT/LCD)
    mode. Should this occur, turn off the LCD display on the notebook computer and output the display data
    in “CRT only” mode. Details on how to change display modes can be found in your notebook computer
    owner’s manual.
    •When this projector receives 640 × 350 VESA format VGA signals, “640 × 400” appears on the screen.
    •When projecting the RGB interlace signal using COMPUTER 1/2 with “Signal Type” set to “Auto” or
    “RGB”, the image may not be projected as desired. In this case, select either VIDEO or S-VIDEO.
    •When “Screen resolution” of the computer is different from the resolution displayed on the projected
    image, follow the procedures shown below.
    –Refer to “Setting the Resolution” on page 53 and select the same resolution as the resolution in “Screen
    resolution” of the computer.
    –Depending on the computer you are using, the output signal may not be faithful to the “Screen resolu-
    tion” adjustment. Check the settings of the computer’s signal output. If the settings cannot be changed,
    it is recommended that the resolution be set to the one that corresponds to “True” in the “Display”
    column.
    DTV
    15.7
    31.5
    33.8
    15.6
    31.3
    45.0
    37.5
    33.8
    33.8
    28.1
    67.5
    56.3 480I480P
    540P
    576
    I576P
    720P
    1035
    I
    1080I
    1080P*60
    60
    60
    50
    50
    60
    50
    60
    60
    50
    60
    50
    Signal Vertical Frequency (Hz)DVI/HDMI Support 
    (Compatible with HDCP)  Horizontal Frequency (kHz)
    * When 1080P signal is input, the image is compressed before it is displayed on the screen.
    Computer Compatibility Chart 
    						
    							77
    STANDBY-ON button
    UNDO button
    H&V LENS SHIFT
    button
    Po wer cord
    1
    2
    1Press  STANDBY-ON  on the projec-
    tor or on the remote control to put
    the projector into standby mode.
    • Disconnect the power cord and unplug the
    power cord from the AC socket after the
    cooling fan stops.
    2Remove the lens cover.
    •Press the lens cover removal button ( 1).
    Slide the lens cover forward ( 2).
    3Turn the lens in the direction of the
    arrow while pressing the lens re-
    moval lever to pull the lens out.
    Do not attempt to exchange the lens when the
    projector is installed hanging from the ceiling.
    Injury may occur if the lens cover and lens fall.
    Before exchanging the lens, reset lens shift to the
    center position. (The lens shift is located at the
    center in the factory preset.)
    When resetting the lens shift to the center position,
    press  H&V LENS SHIFT  and then press  UNDO.
    • The lens shift reset screen will be displayed.
    Select “Yes” to reset.
    Attaching the Optional Lens
    Removal lever 
    						
    							78
    4Remove the lens cap from a re-
    placement lens.
    5Insert the hook of the replacement
    lens to the notch, and turn the lens
    in the direction of the arrow.
    •Make sure that the lens is locked with the
    lens removal lever when you hear a click
    sound.
    6Slide and attach the lens cover.
    •The power cannot be turned on unless the
    lens cover is fully inserted.
    7After changing (setting) the lens,
    select the correct lens type. (See
    page  62.)
    Attaching the Optional Lens
    Info
    If you try to attach the lens to the projector 
    without removing this cap, the optional lens 
    attachment part can be damaged. 
    						
    All Eiki manuals Comments (0)

    Related Manuals for Eiki Projector Eip Wx5000 User Manual