    Have a look at the manual DuVoice Hot Swappable Drive Replacement For The DV2000 With Rack Mount Chassis Technical Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 17 DuVoice manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
      DV2000                                                            Technical Notes   
    PAGE 1 OF 3 
     
    Hot swappable drive replacement for the DV2000 with Rack-mount chassis 
     
    LAST UPDATED 2/21/02  Hot swappable drive replacement for the DV2000 with Rack-mount chassis 
     
    Overview 
     
    This document provides helpful hints for drive replacement in the unlikely 
    event of a drive failure with the Adaptec®
     RAID 1 controller connected to 
    hot-swappable hard-drive carriers and frames in a DV2000 rack-mount 
    system.  For more detailed information, refer to the Adaptec®
     SCSI RAID 
    2100S Installation Guide provided with your DV2000 system. 
     
     
    Storage Manager Pro: 
     
     The Graphic User Interface (GUI) that interacts with the storage subsystem 
    to provide an intuitive graphical interface that enables the technician to do 
    such things as create and manage RAID arrays, set up security levels for 
    users and administrators and establish the means of notifying users of disk 
    failures, etc.  For more detailed information, refer to the Storage 
    Management Users Guide provided with the DV2000 system (in .PDF 
    format on the Adaptec®
     CD). 
     
     ____________________________________________________________
    _ 
    R Note:  The technician will be prompted to provide a user ID and password when 
    starting Storage Manager Pro.  The default user ID is administrator; the default 
    password is adaptec. 
     ____________________________________________________________
    _ 
     
     Certain functions may also be done from the CTRL-A menu on system 
    reboot but should only be undertaken at the direction of DuVoice Technical 
    Support. 
     
    Hot-swappable carrier/frame: 
     
     As the title implies, this consists of two components.  The frame is the 
    component that is permanently mounted within the PC and connected to  
    						
    							 
      DV2000                                                            Technical Notes   
    PAGE 2 OF 3 
     
    Hot swappable drive replacement for the DV2000 with Rack-mount chassis 
     
    LAST UPDATED 2/21/02  the Adaptec®
     RAID Controller.  The carrier; is the component which houses 
    a hard-disk drive that is removable by unlocking from the frame (using the 
    keys provided with your system) and pulling straight out (using the attached 
    handle).  It can be re-inserted by reversing the process. 
     
     ____________________________________________________________
    _ 
    R Notes:  When re-inserting, allow the handle on the carrier to close and push the 
    carrier in until it catches and feels secure, then lock.    
              
            If a carrier has been removed from the system, it will likely require a rebuild 
    upon re-insertion. 
     ____________________________________________________________
    _ 
     
     The carrier also defines the SCSI ID number for that particular drive.  The 
    actual drive inside the carrier is always set to SCSI ID 0 and the carrier 
    provides the translation to the controller.  There are only two choices in this 
    configuration, SCSI ID 0 or SCSI ID 1 (ID numbers are displayed on the 
    front of the carrier when power is applied).  The ID is set on the carrier by 
    means of a thumbwheel on the backside of the carrier (the end that is 
    inserted into the frame).  Normally, it shouldn’t be necessary to set  (or 
    adjust) the SCSI ID settings. 
     
      
     
    Drive failure: 
     
    % In the event of a drive failure, an alarm will sound continuously and the 
    failed drive will be taken offline.  The system should operate normally on the 
    single mirrored drive that remains online.  
     
    : Launch the Storage Manager Pro program by clicking on the Start menu, 
    highlight Programs|Adaptec®
     Storage Manager Pro, and double-click on the 
    Adaptec®
     Storage Manager Pro option.   The technician will be prompted for 
    the User ID and password, refer to the Storage Manager Pro Note 
    discussed earlier in this document for defaults. 
     
    Once logged on, select the Open System option.   The Storage Manager 
    Pro System Browser will launch a four-window display.  Highlight the 
    Adaptec®
     2100S Array in the Device window.  Select Silence Alarm from 
    the list of menu options on the right. 
      
    						
    							 
      DV2000                                                            Technical Notes   
    PAGE 3 OF 3 
     
    Hot swappable drive replacement for the DV2000 with Rack-mount chassis 
     
    LAST UPDATED 2/21/02  V Review the drives in the Device window by single clicking on the symbol to 
    the left of the Adaptec®
     2100S Array item, then single-click the Channel 0 
    item to expand the display to show both hard drives.  An V should be 
    displayed next to one of the drives.  The drives are identified by their ID 
    numbers; (0:00:0) equals ID 0, and (0:01:0) equals ID 1. 
     
     
     
    Remove the corresponding failed drive (carrier and all) from the rack-
    mount system and replace drive (carrier and all) with a known-good spare 
    as described earlier in this document. 
     
    After replacing the drive, go to the Array window in Storage Manager Pro’s 
    System Browser.  Highlight the Adaptec®
     2100S Array item and single click 
    the symbol to the left of this item.  This will expand the item to display the 
    Mirror Set (RAID 1) item underneath.  Highlight the Mirror Set (RAID 1) and 
    select the Rebuild option from the menu to the right.  When the Rebuild is 
    complete, the system will once again run in optimal condition. 
     
    The Rebuild status may be viewed in detail by highlighting the Mirror Set 
    (RAID 1) item in the Array window.   Then, select the Tasks tab in the 
    Detail window below.
       
      
    For further assistance, call DuVoice Corporation Technical Support  
    at (425) 889-9790.  
    						