Page 61
6 Maintenance Lamp warning Lamp (continued) HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE ►The projector uses a high-pressure mercury glass lamp. The lamp can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, when the bulb bursts, it is possible for shards of glass to fly into the lamp housing, and for gas containing mercury...
Page 62
6 Maintenance Please check and clean the air filter periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise, which could cause a fire, a burn or malfunction to the projector. When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. Note that the projector may shut down, when the projector heats too much. Please replace the air filter when it is damaged or too soiled. Preparation of a new air filter is...
Page 63
63 Maintenance • Please replace the air filter when it is damaged or too soiled. • When you replace the projection lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector . • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter. • The projector may display the message such as “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal...
Page 64
64 Maintenance Consumption of the battery makes the clock not to work correctly. When the clock is wrong or it has stopped, please replace the battery according to the following procedures. Internal clock batter y 1.Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2.After making sure that the projector has cooled adequately, slowly turn over the projector, so that the bottom is facing. 3.Remove the battery cover. Turn the battery cover in the direction...
Page 65
65 Maintenance Other care In order to ensure the safe use of your projector, please have it cleaned and inspected by your dealer about once every year. 1.Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2.After making sure that the projector is cool adequately, lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the lens directly with your hand. If the lens is flawed, soiled or fogged, it could cause deterioration of...
Page 66
66 Troubleshooting Troubleshooting Related messages When the unit's power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please follow the instructions described below. If the same message is displayed after the remedy, or if a message other than the following appears, please contact your dealer or service company. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the...
Page 67
67 Troubleshooting Regarding the indicator lamps Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please follow the instructions within the table. If the same indication is displayed after the remedy, or if an indication other than the following is displayed, please contact your dealer or service company. (Continued on next page) POWER indicator LAMP indicator TEMP indicatorDescription Lighting In Orange...
Page 68
68 Troubleshooting Regarding the indicator lamps (continued) • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (OFF) side of the power switch, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again. NOTE POWER indicator...
Page 69
69 Troubleshooting Phenomena that may be easy to be mistaken for machine defects ►Never use the projector if abnormal operations such as smoke, strange odor, excessive sound, damaged casing or elements or cables, penetration of liquids or foreign matter, etc. should occur. In such cases, immediately turn off the power switch and then disconnect the power plug from the power outlet. After making sure that the smoke or odor has stopped, contact your dealer or service company. WARNING (Continued on...
Page 70
70 Troubleshooting Phenomena that may be easily mistaken for machine defects (continued) (Continued on next page) PhenomenonCases not involving a machine defectReference page Sound does not come out. The signal cables are not correctly connected.Correctly connect the audio cables. 0 The MUTE function is working.Restore the sound pressing the MUTE or VOLUME button on the remote control. 7 The volume is adjusted to an extremely low level.Adjust the volume to a higher level using the menu...