3 Y VIDEO RGB IN1 RGB IN2DVI-D RGB OUT CONTROL AUDIO-IN REMOTE CONTROL USB DC OUT S-VIDEO LAN COMPONENT VIDEO CB/PBCR/PR R-AUDIO IN-L AUDIO-OUT Connection to the ports C onnectio n to th e p ortsConnection to the ports ARGB IN 1, BRGB IN 2, CRGB OUT D-sub 15pin mini shrink jack • Video signal: RGB separate, Analog, 0.7Vp-p, 75Ω terminated (positive) • H/V. sync. Signal: TTL level (positive/negative) • Composite sync. Signal: TTL level At RGB signal At component video signal Pin Signal 1 Video Red 2 Video Green 3 Video Blue 4 (No connection) 5 Ground 6 Ground Red 7 Ground Green 8 Ground Blue 9 (No connection) 10 Ground 11 (No connection) 12 A : SDA (DDC data), B /C : (No connection) 13 H. sync / Composite sync. 14 V. sync. 15 A : SCL (DDC clock), B /C : (No connection) Pin Signal 1 CR/PR 2Y 3CB/PB 4(No connection) 5Ground 6CR/PR Ground 7Y Ground 8CB/PB Ground 9(No connection) 10Ground 11 15 (No connection) * except for RGB OUT. 1112131415 12345678910 IK N PAB D OQ H E F J R MLC G
4 Connection to the ports DDVI -D DVI-D jack (digital to digital) Pin Signal Pin Signal1 T.M.D.S. Data 2 - 13 - 2 T.M.D.S. Data 2 + 14 +5V Power 3 T.M.D.S. Data 2/4 Shield 15 Ground (+5V, Analog H/V.sync) 4 - 16 Hot-Plug Sense 5 - 17 T.M.D.S. Data 0 - 6 SCL (DDC Clock) 18 T.M.D.S. Data 0 + 7 SDA (DDC Data) 19 T.M.D.S. Data 0/5 Shield 8 Analog V. sync 20 - 9 T.M.D.S. Data 1 - 21 - 10 T.M.D.S. Data 1 + 22 T.M.D.S. Clock Shield 11 T.M.D.S. Data 1/3 Shield 23 T.M.D.S. Clock + 12 - 24 T.M.D.S. Clock - COMPONENT VIDEO EY, FCB/PB, GCR/PR RCA jack x3 • System: 525i(480i), 525p(480p), 625i(576i), 750p(720p), 1125i(1080i) Port Signal Y Component video Y, 1.0±0.1Vp-p, 75Ω terminator with composite C B/PBComponent video CB/PB, 0.7±0.1Vp-p, 75Ω terminator C R/PRComponent video CR/PR, 0.7±0.1Vp-p, 75Ω terminator HS-VIDEO Mini DIN 4pin jack Pin Signal 1 Color signal 0.286Vp-p (NTSC, burst), 75Ω terminator Color signal 0.300Vp-p (PAL/SECAM, burst) 75Ω terminator 2 Brightness signal, 1.0Vp-p, 75Ω terminator 3 Ground 4 Ground IVIDEO RCA jack • System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43, PAL60 • 1.0±0.1Vp-p, 75Ω terminator 1615141312111092423222120191817 87654321 4 3 21
5 Connection to the ports LAUDIO IN (Ø3.5 stereo mini jack), JKAUDIO INL/R (RCA jack) • 200mVrms(max.) 50kΩ termination MAUDIO OUT (Ø3.5 stereo mini jack) • 200mVrms(max.) 1kΩ output impedance OUSB USB B type jack Pin Signal 1 +5V 2 - Data 3 + Data 4 Ground NCONTROL D-sub 9pin plug • About the details of RS-232C communication, please refer to the followin\ g page. Pin Signal Pin Signal Pin Signal1 (No connection) 4 (No connection) 7 RTS 2 RD 5 Ground 8 CTS 3 TD 6 (No connection) 9 (No connection) PLAN RJ45 jack QDC OUT DC5V/1.5A(max.) RWIRED REMOTE Ø3.5mm Stereo Mini jack • To be connected with the remote control that came with the projector. 987654321 21 34
6 RS-232C Communication RS-2 32C C om munic a tio nRS-232C Communication 6 7 8 9 1 2 3 4 5 6 7 8 9 12345 CONTROL port RS-232C cable (Cross) RS-232C port of the projector of the computer - (1) (1) CD RD (2) (2) RD TD (3) (3) TD - (4) (4) DTR GND (5) (5) GND - (6) (6) DSR RTS (7) (7) RTS CTS (8) (8) DTS - (9) (9) RI Connecting the cable 1. Turn off the projector and the computer. 2. Connect the CONTROL port of the projector with a RS-232C port of the computer by a RS-232C cable (cross). Use the cable that fulfills t\ he specifi cation shown in the previous page. 3. Turn the computer on, and after the computer has started up turn the projector on. Communications setting 19200bps, 8N1 1. Protocol Consist of header (7 bytes) + command data (6 bytes). 2. Header BE + EF + 03 + 06 + 00 + CRC_low + CRC_high CRC_low : Lower byte of CRC fl ag for command data CRC_high : Upper byte of CRC fl ag for command data 3. Command data Command data chart byte_0 byte_1 byte_2 byte_3 byte_4 byte_5 Action Type Setting code low high low high low high Action (byte_0 - 1) Action Classifi cation Content1 SET Change setting to desired value. 2 GET Read projector internal setup value. 4 INCREMENT Increment setup value by 1. 5 DECREMENT Decrement setup value by 1. 6 EXECUTE Run a command.
7 RS-232C Communication (continued) Requesting projector status (Get command) (1) Send the request code Header + Command data (‘02H’+‘00H’\ + type (2 bytes)+‘00H’ +‘00H’) from the computer to the projector. (2) The projector returns the response code ‘1DH’+ data (2 bytes) to\ the computer. Changing the projector settings (Set command) (1) Send the setting code Header + Command data (‘01H’+‘00H’\ + type (2 bytes) + setting code (2 bytes)) from the computer to the projector. (2) The projector changes the setting based on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. Using the projector default settings (Reset Command) (1) The computer sends the default setting code Header + Command data (‘\ 06H’+ ‘00H’ + type (2 bytes) +‘00H’+‘00H’) to the projector. (2) The projector changes the specifi ed setting to the default value. (3) The projector returns the response code ‘06H’ to the computer. Increasing the projector setting value (Increment command) (1) The computer sends the increment code Header + Command data (‘04H’\ + ‘00H’+ type (2 bytes) +‘00H’+‘00H’) to the projecto\ r. (2) The projector in creases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. Decreasing the projector setting value (Decrement command) (1) The computer sends the decrement code Header + Command data (‘05H’\ + ‘00H’+ type (2 bytes) +‘00H’ + ‘00H’) to the projector. (2) The projector decreases the setting value on the above setting code. (3) The projector returns the response code ‘06H’ to the computer. When the projector cannot understand the received command When the projector cannot understand the received command, the error cod\ e ‘15H’ is sent back to the computer. Sometimes the projector cannot properly receive the command. In such a case, the command is not executed and the error code ‘15H’ is sent back to the computer. If this error code is returned, send the same command again. When the projector cannot execute the received command. When the projector cannot execute the received command, the error code ‘\ 1cH’ + ‘xxxxH’ is sent back to the computer. When the data length is greater than indicated by the data length code, the projector ignore the excess data \ code. Conversely when the data length is shorter than indicated by the data le\ ngth code, an error code will be returned to the computer. NOTE • Operation cannot be guaranteed when the projector receives an undefi\ ned command or data. • Provide an interval of at least 40ms between the response code and any\ other code. • The projector outputs test data when the power supply is switched ON, an\ d when the lamp is lit. Ignore this data. • Commands are not accepted during warm-up.
8 Names Operation Type HeaderCommand Data CRC Action Type Setting Code Power Set Turn off BE EF 03 06 00 2A D3 01 00 00 60 00 00 Turn on BE EF 03 06 00 BA D2 01 00 00 60 01 00 Get BE EF 03 06 00 19 D3 02 00 00 60 00 00 (Example return) 00 00 01 00 02 00 (Off) (On) (Cool down) Input Source Set DVI BE EF 03 06 00 0E D2 01 00 00 20 03 00 RGB IN 1 BE EF 03 06 00 FE D2 01 00 00 20 00 00 RGB IN 2 BE EF 03 06 00 3E D0 01 00 00 20 04 00VIDEO BE EF 03 06 00 6E D3 01 00 00 20 01 00 S-VIDEO BE EF 03 06 00 9E D3 01 00 00 20 02 00 COMPONENT BE EF 03 06 00 AE D1 01 00 00 20 05 00 Get BE EF 03 06 00 CD D2 02 00 00 20 00 00 Error Status Get BE EF 03 06 00 D9 D8 02 00 20 60 00 00 (Example return) 00 00 01 00 02 00 03 00 (Normal) (Cover error) (Fan error) (Lamp error) 04 00 05 00 06 00 07 00 (Temp error) (Air fl ow error) (Lamp time error) (Cool error) 08 00 09 00 10 00 (Filter error) (Filter missing error) (Inner Sencer error) BRIGHT Get BE EF 03 06 00 89 D2 02 00 03 20 00 00Increment BE EF 03 06 00 EF D2 04 00 03 20 00 00 Decrement BE EF 03 06 00 3E D3 05 00 03 20 00 00 BRIGHT Reset Execute BE EF 03 06 00 58 D3 06 00 00 70 00 00 CONTRAST Get BE EF 03 06 00 FD D3 02 00 04 20 00 00 Increment BE EF 03 06 00 9B D3 04 00 04 20 00 00 Decrement BE EF 03 06 00 4A D2 05 00 04 20 00 00 CONTRAST Reset Execute BE EF 03 06 00 A4 D2 06 00 01 70 00 00 MODE Set NORMAL BE EF 03 06 00 23 F6 01 00 BA 30 00 00 CINEMA BE EF 03 06 00 B3 F7 01 00 BA 30 01 00 DYNAMIC BE EF 03 06 00 E3 F4 01 00 BA 30 04 00 Get BE EF 03 06 00 10 F6 02 00 BA 30 00 00 (Example return) 00 00 01 00 04 00 10 00 (Normal) (Cinema) (Dynamic) (Custom) GAMMA Set #1 DEFAULT BE EF 03 06 00 07 E9 01 00 A1 30 20 00 #1 CUSTOM BE EF 03 06 00 07 FD 01 00 A1 30 10 00 #2 DEFAULT BE EF 03 06 00 97 E8 01 00 A1 30 21 00 #2 CUSTOM BE EF 03 06 00 97 FC 01 00 A1 30 11 00 #3 DEFAULT BE EF 03 06 00 67 E8 01 00 A1 30 22 00 #3 CUSTOM BE EF 03 06 00 67 FC 01 00 A1 30 12 00 Get BE EF 03 06 00 F4 F0 02 00 A1 30 00 00 R S-2 32C C om munic a tio n ( c o ntin ued)RS-232C Communication (continued)
9 Names Operation Type HeaderCommand Data CRC Action Type Setting Code User Gamma Pattern Set Off BE EF 03 06 00 FB FA 01 00 80 30 00 00 9 step gray scale BE EF 03 06 00 6B FB 01 00 80 30 01 00 15 steps gray scale BE EF 03 06 00 9B FB 01 00 80 30 02 00 Ramp BE EF 03 06 00 0B FA 01 00 80 30 03 00 Get BE EF 03 06 00 C8 FA 02 00 80 30 00 00 User Gamma Point 1 Get BE EF 03 06 00 08 FE 02 00 90 30 00 00 Increment BE EF 03 06 00 6E FE 04 00 90 30 00 00 Decrement BE EF 03 06 00 BF FF 05 00 90 30 00 00 User Gamma Point 2 Get BE EF 03 06 00 F4 FF 02 00 91 30 00 00 Increment BE EF 03 06 00 92 FF 04 00 91 30 00 00 Decrement BE EF 03 06 00 43 FE 05 00 91 30 00 00 User Gamma Point 3 Get BE EF 03 06 00 B0 FF 02 00 92 30 00 00 Increment BE EF 03 06 00 D6 FF 04 00 92 30 00 00 Decrement BE EF 03 06 00 07 FE 05 00 92 30 00 00 User Gamma Point 4 Get BE EF 03 06 00 4C FE 02 00 93 30 00 00 Increment BE EF 03 06 00 2A FE 04 00 93 30 00 00 Decrement BE EF 03 06 00 FB FF 05 00 93 30 00 00 User Gamma Point 5 Get BE EF 03 06 00 38 FF 02 00 94 30 00 00 Increment BE EF 03 06 00 5E FF 04 00 94 30 00 00 Decrement BE EF 03 06 00 8F FE 05 00 94 30 00 00 User Gamma Point 6 Get BE EF 03 06 00 C4 FE 02 00 95 30 00 00 Increment BE EF 03 06 00 A2 FE 04 00 95 30 00 00 Decrement BE EF 03 06 00 73 FF 05 00 95 30 00 00 User Gamma Point 7 Get BE EF 03 06 00 80 FE 02 00 96 30 00 00 Increment BE EF 03 06 00 E6 FE 04 00 96 30 00 00 Decrement BE EF 03 06 00 37 FF 05 00 96 30 00 00 User Gamma Point 8 Get BE EF 03 06 00 7C FF 02 00 97 30 00 00 Increment BE EF 03 06 00 1A FF 04 00 97 30 00 00 Decrement BE EF 03 06 00 CB FE 05 00 97 30 00 00 COLOR TEMP Set LOW BE EF 03 06 00 6B F4 01 00 B0 30 01 00 MIDDLE BE EF 03 06 00 9B F4 01 00 B0 30 02 00HIGH BE EF 03 06 00 0B F5 01 00 B0 30 03 00 CUSTOM BE EF 03 06 00 3B F8 01 00 B0 30 10 00 Get BE EF 03 06 00 C8 F5 02 00 B0 30 00 00 COLOR TEMP GAIN R Get BE EF 03 06 00 34 F4 02 00 B1 30 00 00 Increment BE EF 03 06 00 52 F4 04 00 B1 30 00 00 Decrement BE EF 03 06 00 83 F5 05 00 B1 30 00 00 R S-2 32C C om munic a tio n ( c o ntin ued)RS-232C Communication (continued)
10 Names Operation Type HeaderCommand Data CRC Action Type Setting Code COLOR TEMP GAIN G Get BE EF 03 06 00 70 F4 02 00 B2 30 00 00 Increment BE EF 03 06 00 16 F4 04 00 B2 30 00 00 Decrement BE EF 03 06 00 C7 F5 05 00 B2 30 00 00 COLOR TEMP GAIN B Get BE EF 03 06 00 8C F5 02 00 B3 30 00 00 Increment BE EF 03 06 00 EA F5 04 00 B3 30 00 00 Decrement BE EF 03 06 00 3B F4 05 00 B3 30 00 00 COLOR TEMP OFFSET R Get BE EF 03 06 00 04 F5 02 00 B5 30 00 00 Increment BE EF 03 06 00 62 F5 04 00 B5 30 00 00 Decrement BE EF 03 06 00 B3 F4 05 00 B5 30 00 00 COLOR TEMP OFFSET G Get BE EF 03 06 00 40 F5 02 00 B6 30 00 00 Increment BE EF 03 06 00 26 F5 04 00 B6 30 00 00 Decrement BE EF 03 06 00 F7 F4 05 00 B6 30 00 00 COLOR TEMP OFFSET B Get BE EF 03 06 00 BC F4 02 00 B7 30 00 00 Increment BE EF 03 06 00 DA F4 04 00 B7 30 00 00 Decrement BE EF 03 06 00 0B F5 05 00 B7 30 00 00 COLOR Get BE EF 03 06 00 B5 72 02 00 02 22 00 00 Increment BE EF 03 06 00 D3 72 04 00 02 22 00 00 Decrement BE EF 03 06 00 02 73 05 00 02 22 00 00 COLOR Reset Execute BE EF 03 06 00 80 D0 06 00 0A 70 00 00 TINT Get BE EF 03 06 00 49 73 02 00 03 22 00 00 Increment BE EF 03 06 00 2F 73 04 00 03 22 00 00 Decrement BE EF 03 06 00 FE 72 05 00 03 22 00 00 TINT Reset Execute BE EF 03 06 00 7C D1 06 00 0B 70 00 00 SHARPNESS Get BE EF 03 06 00 F1 72 02 00 01 22 00 00 Increment BE EF 03 06 00 97 72 04 00 01 22 00 00 Decrement BE EF 03 06 00 46 73 05 00 01 22 00 00 SHARPNESS Reset Execute BE EF 03 06 00 C4 D0 06 00 09 70 00 00 MY MEMORY Load Set 1 BE EF 03 06 00 0E D7 01 00 14 20 00 00 2 BE EF 03 06 00 9E D6 01 00 14 20 01 00 3 BE EF 03 06 00 6E D6 01 00 14 20 02 00 4 BE EF 03 06 00 FE D7 01 00 14 20 03 00 MY MEMORY Save Set 1 BE EF 03 06 00 F2 D6 01 00 15 20 00 00 2 BE EF 03 06 00 62 D7 01 00 15 20 01 00 3 BE EF 03 06 00 92 D7 01 00 15 20 02 00 4 BE EF 03 06 00 02 D6 01 00 15 20 03 00 RS-2 32C C om munic a tio n ( c o ntin ued)RS-232C Communication (continued)
11 Names Operation Type HeaderCommand Data CRC Action Type Setting Code PROGRESSIVE Set TURN OFF BE EF 03 06 00 4A 72 01 00 07 22 00 00 TV BE EF 03 06 00 DA 73 01 00 07 22 01 00 FILM BE EF 03 06 00 2A 73 01 00 07 22 02 00 Get BE EF 03 06 00 79 72 02 00 07 22 00 00 3D-YCS Set TURN OFF BE EF 03 06 00 E6 70 01 00 0A 22 00 00 NORMAL BE EF 03 06 00 76 71 01 00 0A 22 01 00 STILL IMAGE BE EF 03 06 00 86 71 01 00 0A 22 02 00 Get BE EF 03 06 00 D5 70 02 00 0A 22 00 00 VIDEO NR Set LOW BE EF 03 06 00 26 72 01 00 06 22 01 00 MIDDLE BE EF 03 06 00 D6 72 01 00 06 22 02 00HIGH BE EF 03 06 00 46 73 01 00 06 22 03 00 Get BE EF 03 06 00 85 73 02 00 06 22 00 00 ASPECT Set 4:3 BE EF 03 06 00 9E D0 01 00 08 20 00 00 16:9 BE EF 03 06 00 0E D1 01 00 08 20 01 00 SMALL BE EF 03 06 00 FE D1 01 00 08 20 02 00 NORMAL BE EF 03 06 00 5E DD 01 00 08 20 10 00 Get BE EF 03 06 00 AD D0 02 00 08 20 00 00 OVER SCAN Get BE EF 03 06 00 91 70 02 00 09 22 00 00 Increment BE EF 03 06 00 F7 70 04 00 09 22 00 00 Decrement BE EF 03 06 00 26 71 05 00 09 22 00 00 OVER SCAN Reset Execute BE EF 03 06 00 EC D9 06 00 27 70 00 00 V POSITION Get BE EF 03 06 00 0D 83 02 00 00 21 00 00 Increment BE EF 03 06 00 6B 83 04 00 00 21 00 00 Decrement BE EF 03 06 00 BA 82 05 00 00 21 00 00 V POSITION Reset Execute BE EF 03 06 00 E0 D2 06 00 02 70 00 00 H POSITION Get BE EF 03 06 00 F1 82 02 00 01 21 00 00 Increment BE EF 03 06 00 97 82 04 00 01 21 00 00 Decrement BE EF 03 06 00 46 83 05 00 01 21 00 00 H POSITION Reset Execute BE EF 03 06 00 1C D3 06 00 03 70 00 00 H PHASE Get BE EF 03 06 00 49 83 02 00 03 21 00 00 Increment BE EF 03 06 00 2F 83 04 00 03 21 00 00 Decrement BE EF 03 06 00 FE 82 05 00 03 21 00 00 H SIZE Get BE EF 03 06 00 B5 82 02 00 02 21 00 00 Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00 Decrement BE EF 03 06 00 02 83 05 00 02 21 00 00 H SIZE Reset Execute BE EF 03 06 00 68 D2 06 00 04 70 00 00 AUTO ADJUST Execute BE EF 03 06 00 91 D0 06 00 0A 20 00 00 R S-2 32C C om munic a tio n ( c o ntin ued)RS-232C Communication (continued)
12 Names Operation Type HeaderCommand Data CRC Action Type Setting Code COLOR SPACE Set AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00 RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00 SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00 REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00 REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00 Get BE EF 03 06 00 3D 72 02 00 04 22 00 00 COMPONENT Set COMPONENT BE EF 03 06 00 4A D7 01 00 17 20 00 00 SCART RGB BE EF 03 06 00 DA D6 01 00 17 20 01 00Get BE EF 03 06 00 79 D7 02 00 17 20 00 00 VIDEO FORMAT Set AUTO BE EF 03 06 00 9E 75 01 00 00 22 0A 00 NTSC BE EF 03 06 00 FE 71 01 00 00 22 04 00PAL BE EF 03 06 00 6E 70 01 00 00 22 05 00 SECAM BE EF 03 06 00 6E 75 01 00 00 22 09 00 NTSC4.43 BE EF 03 06 00 5E 72 01 00 00 22 02 00 M-PAL BE EF 03 06 00 FE 74 01 00 00 22 08 00N-PAL BE EF 03 06 00 0E 71 01 00 00 22 07 00 Get BE EF 03 06 00 0D 73 02 00 00 22 00 00 DVI Set DVD BE EF 03 06 00 3E D9 01 00 20 20 00 00 COMPUTER BE EF 03 06 00 AE D8 01 00 20 20 01 00 Get BE EF 03 06 00 0D D9 02 00 20 20 00 00 KEYSTONE V Get BE EF 03 06 00 B9 D3 02 00 07 20 00 00 Increment BE EF 03 06 00 DF D3 04 00 07 20 00 00 Decrement BE EF 03 06 00 0E D2 05 00 07 20 00 00 KEYSTONE V Reset Execute BE EF 03 06 00 08 D0 06 00 0C 70 00 00 KEYSTONE H Get BE EF 03 06 00 E9 D0 02 00 0B 20 00 00 Increment BE EF 03 06 00 8F d0 04 00 0B 20 00 00 Decrement BE EF 03 06 00 5E D1 05 00 0B 20 00 00 KEYSTONE H Reset Execute BE EF 03 06 00 98 D8 06 00 20 70 00 00 WHISPER Set NORMAL BE EF 03 06 00 3B 23 01 00 00 33 00 00 WHISPER BE EF 03 06 00 AB 22 01 00 00 33 01 00Get BE EF 03 06 00 08 23 02 00 00 33 00 00 MIRROR Set NORMAL BE EF 03 06 00 C7 D2 01 00 01 30 00 00 H:INVERT BE EF 03 06 00 57 D3 01 00 01 30 01 00V:INVERT BE EF 03 06 00 A7 D3 01 00 01 30 02 00 H&V:INVERT BE EF 03 06 00 37 D2 01 00 01 30 03 00 Get BE EF 03 06 00 F4 D2 02 00 01 30 00 00 VOLUME Get BE EF 03 06 00 31 D3 02 00 01 20 00 00 Increment BE EF 03 06 00 57 D3 04 00 01 20 00 00 Decrement BE EF 03 06 00 86 D2 05 00 01 20 00 00 R S-2 32C C om munic a tio n ( c o ntin ued)RS-232C Communication (continued)