Dukane Imagepro 8909 Liquid Crystal Projector Users Manual
Here you can view all the pages of manual Dukane Imagepro 8909 Liquid Crystal Projector Users Manual. The Dukane manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 21
ItemDescription VOLUMEVolume Adjustment :Press the VOLUME / button. MUTE (*)Set/Clear Mute Mode :Press the MUTE button. No sound is heard in the MUTE mode. AUTO Automatic Adjustment at RGB Input :Press the AUTO button. Horizontal position(H.POSIT), vertical position (V.POSIT),clock phase (H.PHASE), and horizontal size(H.SIZE) are automatically adjusted. Use with the window at maximum size in the application display. Automatic Adjustment at Video Input :Press the AUTO button. A signal type appropriate for...
Page 22
ENGLISH-12ENGLISH-12 O O O O P P P P E E E E R R R R A A A A T T T T I I I I O O O O N N N N S S S S ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Setup MenuThe following adjustments and settings are possible when SETUP is selected at the top of the menu. Part of the Setup menu differs between RGB input and video input. Select an item with the and buttons, and start operation. Use the Single menu to reduce menu size (see Table 3, MENU SELECT). Table 4....
Page 23
ENGLISH-13 ENGLISH ENGLISH-13 O O O O P P P P E E E E R R R R A A A A T T T T I I I I O O O O N N N N S S S S ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Input MenuThe following functions are available when INPUT is selected on the menu. Select an item with the and buttons, and start or stop operation with the and buttons. The function indicated (**) are effective on video input mode only, not on RGB input mode, except in the P.IN P. window on RGB input...
Page 24
ENGLISH-14ENGLISH-14 O O O O P P P P E E E E R R R R A A A A T T T T I I I I O O O O N N N N S S S S ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Image Menu The following adjustments and settings are available when IMAGE is selected on the menu. Select an item with the and buttons, and start operation. Table 6. Image Menu KEYSTONE BLANK MIRROR START UP P. IN P.+1 SETUP INPUT OPT.IMAGE ItemDescription KEYSTONE Keystone Adjustment: Reduce size of bottom...
Page 25
ENGLISH-15 ENGLISH ENGLISH-15 O O O O P P P P E E E E R R R R A A A A T T T T I I I I O O O O N N N N S S S S ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Options Menu The following adjustments and settings are available when OPT. is selected on the menu. Select an item with the and buttons, and start operation. The function indicated (**) are effective on video input mode only, not on RGB input mode, except in the P.IN P. window on RGB input mode. Table...
Page 26
ENGLISH-16ENGLISH-16 O O O O P P P P E E E E R R R R A A A A T T T T I I I I O O O O N N N N S S S S ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) No Signal Menu The same adjustments and settings are available as with the Image and Options menus when the MENU button is pressed during display of the “NO INPUT IS DETECTED ON ***” or “SYNC IS OUT OF RANGE ON ***” message while no signal is received. Table 8. No Signal Menu VOLUME KEYSTONE BLANK MIRROR START...
Page 27
ENGLISH-17 ENGLISH ENGLISH-17 MAINTENANCE MAINTENANCE Lamp HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE Contact your dealer before replacing the lamp. For the optional lamp, see the item “Option Parts” of the Table 12. Before replacing the lamp, switch power OFF, remove the power cord from the power outlet, and wait approximately 45 minutes until the lamp has cooled. The lamp may explode if handled at high temperatures. Lamp Life Projector lamps have a finite life. The image will become darker, and hues...
Page 28
ENGLISH-18ENGLISH-18 M M M M A A A A I I I I N N N N T T T T E E E E N N N N A A A A N N N N C C C C E E E E ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Replacing the Lamp 1. Switch the projector OFF, remove the power cord from the power outlet, and wait at least 45 minutes for the unit to cool. 2. Prepare a new lamp. 3. Check that the projector has cooled sufficiently, and gently turn it upside down. 4. Loosen the screw as shown in the diagram, and...
Page 29
ENGLISH-19 ENGLISH ENGLISH-19 M M M M A A A A I I I I N N N N T T T T E E E E N N N N A A A A N N N N C C C C E E E E ( ( ( ( c c c c o o o o n n n n t t t t i i i i n n n n u u u u e e e e d d d d ) ) ) ) Air Filter Maintenance The air filter should be cleaned as described below at intervals of approximately 100 hours. 1. Switch the projector power supply OFF, and remove the power cord from the power outlet. 2. Clean the air filter with a vacuum cleaner. Other Maintenance Maintenance Inside the...
Page 30
ENGLISH-20ENGLISH-20 TROUBLESHOOTING TROUBLESHOOTING OSD Message The messages as described below may appear on the screen at power ON. Take the appropriate measures when such a message appears. Table 9. OSD Messages MessageContents CHANGE THE LAMP AFTER REPLACING LAMP, RESET THE LAMP TIME. *1) The message shown at left appears after the lamp has been used for more than 1300 hours. The lamp is approaching the end of its life. Power is switched OFF automatically when the lamp reaches the end of its life....