Dukane Imagepro 8755g-Rj Projector Users Manual
Here you can view all the pages of manual Dukane Imagepro 8755g-Rj Projector Users Manual. The Dukane manuals for Projector are available online for free. You can easily download all the documents as PDF.
Page 91
25 Projector Management using SNMP The SNMP (Simple Network Management Protocol) enables to manage the projector information, which is a failure or warning status, from the co\ mputer on the network. The SNMP management software will be required on the computer to use this function. • It is recommended that SNMP functions be carried out by a network administrator. • SNMP management software must be installed on the computer to monitor the projector via SNMP. NOTE SNMP Settings Configure the...
Page 92
26 Event Scheduling Event Scheduling • You can schedule the following control events: Power ON/OFF, Input Source and Transferred Image Display. • The power on / off event has the lowest priority among the all events that are defined at the same time. • There are 3 types of Scheduling, 1) Daily 2) Weekly 3) Specific date (27). • The priority for scheduled events is as follows 1) Specific date 2) Weekly 3) Daily. • Up to five specific dates are available for scheduled events. Priority is given to...
Page 93
Event Scheduling Schedule Settings Schedule settings can be configured from a web browser. Example: If the IP address of the projector is set to 192.168.1.10: There are three types of scheduling. 1) Daily: Perform the specified operation at a specified time every day. 2) Weekly (Sunday ~ Saturday): Perform the specified operation at the specified time on a specified day of the week. 3) Specific date: Perform the specified operation on the specified date and time. • In Standby mode the...
Page 94
Date/Time Settings The Date/Time setting can be adjusted via a web browser. Example: If the IP address of the projector is set to 192.168.1.10: • A Network Restart is required after the Daylight Savings Time or SNTP configuration settings have been changed. • The battery for the built in clock may be dead if the clock loses time e\ ven when the date and time have been set correctly. Replace the battery by following the instructions on replacing the battery. ("Internal clock...
Page 95
29 e-SHOT (Still Image Transfer) Display e-SHOT (Still Image Transfer) Display The projector can display a still image that is transferred via the netw\ ork. Communication Port The following port is used for e-SHOT. TCP #9716 e-SHOT (Still Image Transfer) Settings Configure the following items from a web browser when e-SHOT is used. Example: If the IP address of the projector is set to 192.168.1.10: • e-SHOT is not available via communication ports (TCP #23 and TCP #9715) (9) which are used for...
Page 96
30 e-SHOT (Still Image Transfer) Display e-SHOT (Still Image Transfer) Settings (Continued) When the authentication setting is enabled, the following settings are r\ equired. 6) Click [Security Settings] on the main menu. ) Select [Network Control] and enter the desired authentication password. ) Click the [Apply] button to save the settings. • The Authentication Password will be the same for Network Control Port1 (Port: 23), Network Control Port2 (Port: 9715), and Image Transfer...
Page 97
31 ) Enter "http://192.168.1.10/" into the address bar of the web browser. 2) Enter the Administrator ID and password and click [Logon]. 3) Click [Port Settings] on the main menu. 4) Click the [Enable] check box to open Network Control Port1 (Port: 23) to use TCP #23. Click the [Enable] check box for the [Authentication] setting when authentication is required, otherwise clear the check box. 5) Click the [Enable] check box to open Network Control Port2 (Port: 9715) to use TCP...
Page 98
32 Command Control via the Network Command Control Settings (Continued) When the authentication setting is enabled, the following settings are r\ equired. (17) ) Click [Security Settings] on the main menu. ) Click [Network Control] and enter the desired authentication password. 9) Click the [Apply] button to save the settings. • The Authentication Password will be the same for Network Control Port1 (Port: 23), Network Control Port2 (Port: 9715), and Image Transfer Port (Port:...
Page 99
33 Command Control via the Network Command Format Command formats differ among the different communication ports. ● TCP #23 You can use the RS-232C commands without any changes. The reply data format is the same as the RS-232C commands. However, the following reply will be sent back in the event of authentication failure when authentica\ tion is enabled. ReplyError code 0x1F0x040x00 ● TCP #9715 Send Data format The following formatting is added to the header (0x02), Data length (0x0D), Checksum...
Page 100
34 Command Control via the Network Reply Data format The connection ID (the data is same as the connection ID data on the sending data format) is attached to the RS-232C commands reply data. ReplyConnection ID 0x06 byte ReplyConnection ID 0x15 byte ReplyError codeConnection ID 0x1C bytes byte ReplyDataConnection ID 0x1D bytes byte ReplyStatus codeConnection ID 0x1F bytes byte ReplyAuthentication Error codeConnection ID 0x1F0x040x00 byte Command...