Dukane Imagepro 8755d-Rj Portable Lcd Projector Users Manual
Have a look at the manual Dukane Imagepro 8755d-Rj Portable Lcd Projector Users Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Dukane manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
39 Multifunctional settings ItemDescription SERVICE Selecting this item displays the SERVICE menu.Select an item using the buttons ▲/▼, and press the button ► or the ENTER button on the remote control to execute the item.FAN SPEED AUTO ADJUST GHOST KEY LOCK FILTER MESSAG FACTORY RESET FAN SPEEDUsing the buttons ▲/▼ switches the rotation speed of the cooling fans. The HIGH is the mode for use at highlands etc. Note that the projector is noisier when the HIGH is selected. HIGH NORMAL AUTO ADJUST Using the buttons ▲/▼ enables/disables the automatic adjustment.When DISABLE is selected, the automatic adjustment feature is disabled, although rough adjustment is automatically performed depending on the basic setting. ENABLE DISABLE • Depending on conditions, such as input image, signal cable to the projector, environment around the projector, etc., the automatic adjustment may not work correctly. In such a case, please choose DISABLE to disable the automatic adjustment, and make adjustment manually. GHOST 1. Select a color element of ghost using the buttons ◄/►. 2. Adjust the selected element using the buttons ▲/▼ to disappear ghost. KEY LOCKUsing the buttons ▲/▼ turns on/off the key lock feature. When TURN ON is selected, the buttons on the projector except the STANDBY/ON button are locked. TURN ON TURN OFF• Please use to avoid a mischief and touching accidentally. This function does not have any effect on the remote control. FILTER MESSAGE Use the ▲/▼ button to set the timer for the interval to show the message for cleaning up the air filter. 50h 100h 200h 300h TURN OFFAfter selecting “50h”, “100h”, “200h”, or “300h”, the message “CLEAN THE AIR FILTER” will appear after the timer reaches the interval time set by the menu. (38) When the “TURN OFF” is chosen, the air filter cleaning message will not appear. • Please check and clean the air filter periodically, even if there is no message. If the air filter becomes to be blocked by dust or others, the internal temperature will rise, which could cause malfunction, or reduce the lifetime of the projector. • It is recommended to choose “100h” in general. Please be careful with the operating environment of the projector and the condition of the air filter, especially when the “200h”, “300h or “TURN OFF” is chosen. FACTORY RESET Selecting RESET using the button ▲ performs this function. By this function, all the items in all of menus will collectively return to the initial setting. Note that the items LAMP TIME, FILTER TIME and LANGUAGE are not reset. RESET CANCEL OPTION Menu (continued)
40 Maintenance Maintenance Lamp WARNING HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE ►The projector uses a high-pressure mercury glass lamp. The lamp can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, when the bulb bursts, it is possible for shards of glass to fly into the lamp housing, and for gas containing mercury to escape from the projector’s vent holes. ►About disposal of a lamp • This product contains a mercury lamp; do not put it in a trash. Dispose of it in accordance with environmental laws. For lamp recycling, go to www.lamprecycle.org. (in the US) For product disposal, contact your local government agency or www .eiae.org (in the US) or www.epsc.ca (in Canada). For more information, call your dealer. • If the lamp should break (it will make a loud bang when it does), unplug the power cord from the outlet, and make sure to request a replacement lamp from your local dealer. Note that shards of glass could damage the inside of the projector, or cause injury during handling, so please do not try to clean the projector or replace the lamp yourself. • If the lamp should break (it will make a loud bang when it does), ventilate the room well, and make sure not to breathe the gas that comes out of the projector vents, or get it in your eyes or mouth.• Before replacing the lamp, turn the projector off and unplug the power cord , then wait at least 45 minutes for the lamp to cool sufficiently. Handling the lamp while hot can cause burns, as well as damaging the lamp. • Never unscrew except the appointed (marked by an arrow) screws. • Do not open the lamp cover while the projector is suspended from the ceiling. This is dangerous, since if the lamp’s bulb has broken, the shards will fall out when the cover is opened. In addition, working in high places is dangerous, so ask your local dealer to have the lamp replaced even if the bulb is not broken.• Do not use the projector with the lamp cover removed. To replace the lamp, make sure that the screws are tightened firmly. Loose screws could result in damage or injury. • Use only the lamp of the specified type. • If the lamp breaks soon after the first time it is used, it is possible that there are electrical problems elsewhere besides the lamp. If this happens, contact your local dealer or a service representative.• Handle with care: jolting or scratching could cause the lamp bulb to burst during use.• Using the lamp for long periods of time, could cause it dark, not to light up or to burst. When the pictures appear dark, or when the color tone is poor, please replace the lamp as soon as possible. Do not use old (used) lamps; this is a cause of breakage. Disconnect the plug from the power outlet
41 Lamp (continued) A lamp has a finite product life. Using the lamp for long periods of time could cause the pictures darker or the color tone poor. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. Preparation of a new lamp and early replacement are recommended. To prepare a new lamp, contact your dealer and tell the lamp type number. Type number = DT00731. 1. Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes. 2. Prepare a new lamp. If the projector is mounted on the ceiling, or if the lamp has broken, also ask the dealer to replace the lamp. In the case of replacement by yourself, 3. Loosen the lamp cover screw (marked by arrow) and then slide the lamp cover to the side to remove it. 4. Loosen the 2 screws (marked by arrow) of the lamp, and slowly pick up the lamp by the handles. 5. Insert the new lamp, and retighten firmly the two screws that are loosened in the previous process to lock it in place. 6. Slide the lamp cover back in place and firmly fasten the lamp cover screws. 7. Turn the projector on and reset the lamp time using the LAMP TIME function in the OPTION menu (38). (1) Press the MENU button to display a menu. Only when the EASY MENU has appeared, please perform the next step (2). (2) Point at the “Go To Advance Menu …” in the menu using ▼/▲ button, then press the ► button. (3) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then press the ► button. (4) Point at the ”LAMP TIME” using ▼/▲ button, then press the ► button. A dialog will appear. (5) Press the ▲ button to select “RESET” on the dialog. It performs resetting the lamp time. Maintenance Lamp cover Screw Handle Screws NOTE • Please reset the lamp time only when you have replaced the lamp, for a suitable indication about the lamp.
42 If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn and/or malfunction to the projector. When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible. Please check and clean the air filter periodically, even if there is no message. Please replace the air filter when it is damaged or too soiled. Preparation of a new air filter is recommended. To prepare a new air filter , contact your dealer and tell the air filter type number. Type number = NJ22222 And also when you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector . 1. Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes. 2. When the projector is suspended from the ceiling, apply the vacuum cleaner to and around the filter cover first, to prevent penetration of dust or the like. 3. While supporting the projector with one hand, use your other hand to pull the filter cover forward in the direction of the arrow. Remove the air filter. Maintenance WARNING ►Before caring, make sure the power switch is off and the power cable is not plugged in, then allow the projector to cool suffi ciently. The care in a high temperature state of the projector could cause an electric shock, a burn and/or malfunction to the projector. ►Use only the air filter of the specified type. Do not use the projector with the air filter and the filter cover removed. It could result in a fire and/or malfunction to the projector. ►The air filter should be cleaned periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn and/or malfunction to the projector. Air filter Handle Filter cover NOTE • Please replace the air filter when it is damaged or too soiled, and also when you replace the lamp. • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter. (38) • The projector may display the message such as “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising.
43 Maintenance 4. Apply a vacuum cleaner to the air filter and the filter cover. Please replace the air filter when it is damaged or too soiled. 5. Replace the air filter in its original position. Secure the air filter in place by pressing each of the six locations. Make sure there is no dust or dirt remaining after the cover is in place. If any dust or dirt remains use a vacuum cleaner to remove it as when placing the filter cover on the air filter. Reattach the filter cover to the projector by aligning the filter cover with the grooves on the projector. While holding the handle, push down on the filter cover until it locks firmly in place. 6. Turn the projector on and reset the filter time using the FILTER TIME function in the OPTION menu (38). (1) Press the MENU button to display a menu. When the EASY MENU has appeared, please skip the next step (2). (2) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then press the ► button. (3) Point at the “FILTER TIME” using ▼/▲ button, then press the ► button. A dialog will appear. (4) Press the ▲ button to select “RESET” on the dialog. It performs resetting the lamp time. Air filtre (continued) Filter cover Air filter Air filter’s knob mark Model 8755D-RJ Only! Internal Clock Battery Replacement of battery is discribed on page 45. The clock will not function correctly when the battery is expended. A dead battery will cause the clock to indicate wrong or stopped time.
44 Maintenance WARNING ►Before caring, make sure the power switch is off and the power cable is not plugged in, and then allow the projector to cool suffi ciently. The care in a high temperature state of the projector could cause a burn and/or malfunction to the projector. ►Never try to care for the inside of the projector personally. Doing is so dangerous. ►Avoid wetting the projector or inserting liquids in the projector. It could result in a fire, an electric shock, and/or malfunction to the projector. • Do not put a container containing water, cleaner or chemicals near the projector. • Do not use aerosols or sprays. CAUTION ►Please take right care of the projector according to the following. Incorrect care could cause not only an injury but adverse influence such as discoloration, peeling paint, etc. ►Do not use cleaner or chemicals other than those listed below. ►Do not polish or wipe with hard objects. Inside of the projector In order to ensure the safe use of your projector, please have it cleaned and inspected by your dealer about once every year. Caring for the lens If the lens is flawed, soiled or fogged, it could cause deterioration of display quality. Please take care of the lens, being cautious of handling. 1. Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently . 2. After making sure that the projector is cool adequately, lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the lens directly with your hand. Caring for the cabinet and remote control Incorrect care could have adverse influence such as discoloration, peeling paint, etc. 1. Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2. After making sure that the projector is cool adequately , lightly wipe with gauze or a soft cloth. If soiling is severe, dip soft cloth in water or a neutral cleaner diluted in water , and wipe lightly after wringing well. Then, wipe lightly with a soft, dry cloth. Other care
45 1. Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. 2. After making sure that the projector has cooled adequately, slowly turn over the projector, so that the bottom is facing. 3. Remove the battery cover. Turn the battery cover in the direction indicated “OPEN” using such as coins. Then the battery cover will come up. While removing the battery cover, pick its knob. 4. Take the old battery out. Press the metal claw of the battery holder. Then the battery will come up. Remove the battery. 5. Put a new battery in. Replace battery with HITACHI MAXELL, Part No.CR2032 only. Use of another battery may present a risk of fire or explosion.Insert a new battery in the battery holder according to its minus terminal as indicated in the battery holder, so that the side marked by + is facing. And push the battery into the battery holder fully to fix. 6. Close the battery cover. Replace the battery cover in place, then turn it in the direction indicated “CLOSE” using such as coins, to fix. CLOSE Battery Cover OPEN Knob Metal claw “+” marking Maintenance WARNING ►Always handle the batteries with care and use them only as directed. Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fi re. And also improper use may result in cracking or leakage, which could result in fi re, injury and/or pollution of the surrounding environment.• Be sure to use only the batteries specified. Do not use batteries of different types at the same time. Do not mix a new battery with used one.• Make sure the plus and minus terminals are correctly aligned when loading a battery .If the battery is placed in the battery holder upside-down, it may be hard to remove.• Keep a battery away from children and pets. If swallowed consult a physician immediately for emergency treatment.• Do not short circuit or solder a battery.• Do not allow a battery in a fire or water. Keep batteries in a dark, cool and dry place. • If you observe a leakage of a battery, wipe out the flower and then replace a battery. If the liquid adheres to your body or clothes, rinse well with water immediately . • Obey the local laws on disposing the battery. Replacing Internal Clock batter y (8755D-RJ only!) Consumption of the battery makes the clock not to work correctly. When the clock is wrong or it has stopped, please replace the battery according to the following procedures. NOTE • The internal clock’s time will be reset when the battery is removed. Please reconfigure the time via the menu or a web browser after replacing the battery. (Please refer to page 76 - Network Functions: Date/Time Settings for more information.) If the battery is placed in the battery holder upside-down, follow the procedure below to remove and reload it properly. 1. Remove the battery cover as described in steps 1 through 3 above. 2. Turn the projector over again, so that the top of the projector is facing up. 3. While lifting the side of the projector closest to the lens, press the metal claw of the battery holder. The battery will fall out of the holder, so be careful not to lose it. 4. Turn the projector over once more, so that the bottom faces up, and reload the battery correctly.
47 Troubleshooting Related messages When the unit's power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please follow the instructions described below. If the same message is displayed after the remedy, or if a message other than the following appears, please contact your dealer or service company. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the power is turned on. MessageDescription NO INPUT IS DETECTEDON *** There is no input signal. Please confirm the signal input connection, and the status of the signal source. SYNC IS OUT OF RANGEON *** fH *****kHz fV *****Hz The horizontal or vertical wavelength of the input signal is out of the response parameter range of this unit. Please confirm the specs for your projector or the signal source specs. CHECK THE AIR FLOW The internal temperature is rising. Please turn the power off, and allow the projector to cool down at least 20 minutes. After having confirmed the following items, please turn the power ON again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? If the same ind ication is displayed after the remedy, please set FAN SPEED of the SERVICE item in the OPTION menu to HIGH . REMINDER *** HRS PASSED AFTER THE LAST FILTER CHECK. FILTER MAINTENANCE IS ESSENTIAL TO REMOVE WARNING MESSAGE, RESET FILTER TIMER. SEE MANUAL FURTHER INFO. A note of precaution when cleaning the air filter. Please immediately turn the power off, and clean or change the air filter referring to the “Air Filter” section of this manual. After you have cleaned or changed the air filter, please be sure to reset the filter timer. ( 38).
48 Troubleshooting Regarding the indicator lamps Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please follow the instructions within the table. If the same indication is displayed after the remedy, or if an indication other than the following is displayed, please contact your dealer or service company. POWER indicatorLAMP indicatorTEMP indicatorDescription Lighting In Orange Turned offTurnedoff The projector is in a standby state. Please refer to the section “Power On/Off”. Blinking In Green Turned offTurnedoff The projector is warming up. Please wait. Lighting In Green Turned offTurnedoff The projector is in an on state. Ordinary operations may be performed. Blinking In Orange Turned offTurnedoff The projector is cooling down. Please wait. Blinking In Red (discre- tionary) (discre- tionary) The projector is cooling down. A certain error has been detected. Please wait until the POWER indicator finishes blinking, and then perform the proper measure using the item descriptions below. Blinking In Red or Lighting In Red Lighting In Red Turned off The lamp does not light, and there is a possibility that interior portion has become heated. Please turn the power off, and allow the projector to cool down at least 20 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? If the same indication is displayed after the remedy, please change the lamp referring to the section “Lamp”. Blinking In Red or Lighting In Red Blinking In Red Turned off The lamp cover has not been properly fixed. Please turn the power off, and allow the projector to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp cover. After performing any needed maintenance, turn the power on again. If the same indication is displayed after the remedy, please contact your dealer or service company.