Description
When the DRAC 5 cfgSerialConsoleEnable property is set to 0 (disabled), 
the DRAC 5 serial port becomes the IPMI serial port. This property 
determines the IPMI defined mode of the serial port. 
In Basic mode, the port uses binary data with the intent of communicating 
with an application program on the serial client. In Terminal mode, the port 
assumes that a dumb ASCII terminal is connected and allows very simple 
commands to be...

Page 382

382DRAC 5 Property Database Group and Object Definitions
cfgIpmiSerialFlowControl (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (None)
1 (CTS/RTS)
2 (XON/XOFF)
Default
1
Description
Specifies the flow control setting for the IPMI serial port.
cfgIpmiSerialHandshakeControl (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (FALSE)
1 (TRUE)
Default
1
Description
Enables or disables he IPMI terminal...

Page 383

DRAC 5 Property Database Group and Object Definitions383
Default
1
Description
Enables or disables line editing on the IPMI serial interface.
cfgIpmiSerialEchoControl (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (FALSE)
1 (TRUE)
Default
1
Description
Enables or disables echo control on the IPMI serial interface.
cfgIpmiSerialDeleteControl (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0...

Page 384

384DRAC 5 Property Database Group and Object Definitions
Legal Values
0 (None)
1 (CR-LF)
2 (NULL)
3 ()
4 ()
5 ()
Default
1
Description
Specifies the newline sequence specification for the IPMI serial interface.
cfgIpmiSerialInputNewLineSequence (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 ()
1 (NULL)
Default
1
Description
Specifies the input newline sequence specification for the IPMI serial 
interface.
cfgIpmiSol
This group is used to configure...

Page 385

DRAC 5 Property Database Group and Object Definitions385
cfgIpmiSolEnable (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (FALSE)
1 (TRUE)
Default
1
Description
Enables or disables Serial Over LAN (SOL).
cfgIpmiSolBaudRate (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
9600, 19200, 57600, 115200
Default
57600
Description
The baud rate for serial communication over LAN.
cfgIpmiSolMinPrivilege...

Page 386

386DRAC 5 Property Database Group and Object Definitions
Default
4
Description
Specifies the minimum privilege level required for serial over LAN access.
cfgIpmiSolAccumulateInterval (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
1 – 255.
Default
10
Description
Specifies the typical amount of time that the BMC waits before transmitting 
a partial SOL character data packet. This value is 1-based 5ms increments.
cfgIpmiSolSendThreshold (Read/Write)...

Page 387

DRAC 5 Property Database Group and Object Definitions387
cfgIpmiLanEnable (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (FALSE)
1 (TRUE)
Default
1
Description
Enables or disables the IPMI-Over-LAN interface.
cfgIpmiLanPrivLimit (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
2 (User)
3 (Operator)
4 (Administrator)
Default
0
Description
Specifies the maximum privilege level allowed for IPMI over...

Page 388

388DRAC 5 Property Database Group and Object Definitions
Default
1
Description
Enables or disables global e-mail alerting. This property overrides all 
individual e-mail alerting enable/disable properties.
cfgIpmiEncryptionKey (Read/Write)
 NOTE: To view or modify this property, you must have Configure DRAC 5 
permission and administrator privileges.
Legal Values
A string of hexadecimal digits from 0 to 20 characters with no spaces.
Default
00000000000000000000
Description
The IPMI encryption key....

Page 389

DRAC 5 Property Database Group and Object Definitions389
cfgIpmiPef
This group is used to configure the platform event filters available on the 
managed server.
The event filters can be used to control policy related to actions that are 
triggered when critical events occur on the managed system.
cfgIpmiPefName (Read Only)
Legal Values
String. Maximum Length = 255.
Default
The name of the index filter.
Description
Specifies the name of the platform event filter.
cfgIpmiPefIndex (Read Only)
Legal Values
1...

Page 390

390DRAC 5 Property Database Group and Object Definitions
cfgIpmiPefAction (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (None)
1 (Power Down)
2 (Reset)
3 (Power Cycle)
Default
0
Description
Specifies the action that is performed on the managed system when the alert 
is triggered.
cfgIpmiPefEnable (Read/Write)
 NOTE: To modify this property, you must have Configure DRAC 5 permission.
Legal Values
0 (FALSE)
1 (TRUE)
Default
1
Description
Enables or...