GB 2 Before any installation, use or maintenance operation, read the safety i\ nstructions in this manual carefully . Remove all packaging materials from the unit. Keep all packaging away fr\ om babies and small children to avoid the danger of suffocation. Before inserting the power plug, please make sure that the voltage is wi\ thin the range indicated on the unit. The dehumidifier is intended exclusively for the use for which it was cr\ eated. Amcor is not responsible for any damage caused by improper use. As with all electrical appliances, please use with care. The first time that you use the unit please ensure that it has been stan\ ding for 2 hours in an upright position before it is switched on. NOTE: The unit is not to be used in temperatures under 5 °C. IMPORT ANT! • The u nit i s d esign ed f or i ndoor op era ti on . • Rating: T his u nit m ust b e c onnecte d t o a 2 20 -2 4 0 V ~ / 5 0H z e arth ed o utle t. • The i nsta ll a ti on m ust b e in a ccor da nce w ith r eg u la ti on s o f the c ou n tr y w here t he u n it i s u se d . If you are in any doubt about the electrical installation, have it check\ ed and if necessary modified by a qualified electrician. Thank you for choosing this innovative Home Dehumidifier. We suggest that you keep this manual in a safe place for future reference. It explains the m\ any benefits and advanced features this unique product has to offer . Before you use your new dehumidifier you should carefully read these instructions to maximise p\ roduct performance. F or over 60 years Amcor has specialised in complete indoor environmental \ control; manufacturing and marketing dehumidifiers, portable air conditioners, co\ olers, air purifiers, ionisers and aroma therapy scent diffusers. These world class\ products incorporate the latest technological developments. T H AN K Y OU ! IMPORTANT SAFETY INSTRUCTIONS
GB 3 Do not use your dehumidifier under the following conditions: Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the power cable wires are frayed or cut When small children may be left unattended If an extension lead is needed to reach an outlet Where the power cable may be damagedOn a slope or uneven surface Where it may be damaged by chemicals Where there is a risk of interference by foreign objects This product is not made for DIY repair If there is a risk of liquid falling on the unit • Unp lug w hen n ot i n u se . D o n ot unp lug b y pulli n g the c ord. • Do n ot op era te t his p ro du ct w ith w et h an ds. • Keep o ut o f the r ea ch o f chil d re n . • Do n ot c le an the u nit b y spra yin g it or i mmer sin g it i n wate r. • Dis con nect it f rom the m ain s b efor e c le ani ng the u nit or a ny o f its c om pon en ts . • Alw ays unp lug b efor e c han gi ng the f ilt e r. • Do n ot c on nect the u nit t o a n e le ctr ic a l o utle t u sin g a n e xte n sion c ord. I f a n o u tle t i s n ot a vail able, on e shou ld b e insta ll e d b y a l ic e n se d e le ctr ic ian . • This a pp lian ce i s n ot i nte n ded f or u se b y pers on s (in clu din g c hil d re n ) w ith r e d u ce d p hys ic a l, s en sor y or men ta l c apa bilitie s, or l ack o f exp erie nce a nd k now le dge , unl ess the y have b een gi ve n s up erv isi on or i nstr ucti on c once rn in g the u se o f the a pp lian ce b y a p ers on r esp on sible f or thei r safety . • Chil d re n s hou ld b e sup erv is e d t o e nsu re t hat the y do n ot p la y w ith the a pp lian ce . If the power cord is damaged, it must be replaced by an approved service\ representative or a similar qualified person in order to avoid any hazar\ d.
GB 4 Y our AMCOR dehumidifier will begin to protect your home from the harmful \ effects of excessive moisture as soon as it is turned on. Excess moisture travels throughout your home, in the same way cooking sm\ ells spread around the house. F or this reason, the dehumidifier should be positioned in a central and clear location so that it can draw the moist air from all ov\ er the home. A warm hallway or landing is an excellent position for your dehumidifier . If possible, leave interior doors ajar to allow air circulation. Alternatively , if you have a serious problem in one area you can begin by positioning\ the dehumidifier there and moving it to a more central location at a lat\ er date. F or the most effective use, run your dehumidifier with external doors and\ windows kept closed. Please note the unit should not be placed directly against a radiator or other heat source. When positioning your AMCOR dehumidifier , ensure that it is placed securely on a level surface clear of any obstacle that may limit the air movement. Y our AMCOR dehumidifier is fitted with 4 wheels for easy movement. Before\ you move the unit, switch it off and empty the water tank. IMPORT ANT: Keep a minimal 0.2 m safety distance between the appliance and an electr\ ical heater or any inflammable surface. C ontrol panel Air outlet grill W ater tank C astors Handle Air inlet, filter C ontinuous drainage port Supply cord P LA C EM EN T PA R Ts
GB 5 Switching the unit ON and O ff When the unit is plugged in, a buzzer will beep. Press the ON/OFF button (A) to start the dehumidifier with the default\ low fan speed, LED [3] will light. When the room humidity is between 40% to 90%, the unit will dehumidify automatically and LED [1] will light. The unit will stop dehumidifying when the relative humidity becomes lowe\ r than 40% or higher than 90%, LED [1] will go off, but the fan continues to circulate the air . Press the power button (A) to switch the unit off. Setting the fan speed Press the FAN SPEED button (B) the change the desired fan speed, the h\ igh speed LED [4] or low speed LED [3] will light accordingly . When the dehumidifier is running in room temperatures between 5 °C an\ d 12 °C, it will stop operating every 30 minutes to defrost. In room temperatures between 12 °C and 20 °C, the dehumidifier wil\ l stop to defrost every 45 minutes. 1234 AB O PER ATIO N
GB 6 Always unplug the unit from the mains before carrying out any maintenanc\ e or cleaning the unit. Cleaning the body Use only a soft cloth to wipe the unit clean. Do not use volatile chemicals, petrol, detergents, chemically treated cl\ oths or other harmful cleansing solutions. These could cause damage to the unit. Cleaning the washable air filter This dehumidifier is equipped with a washable filter . This will capture most airborne pollutants like dust, smoke, animal dander , mould spores and pollen to create a less irritating living environment. It is advisable to check the filter on a regular basis (at least monthly and after storage) and clean as necessary: • Extr act t he f ilt e r h old er • Use a v acu um c le an er or t ap t he f ilt e r l ig ht ly . If the filter is particularly dirtY, use lukewarm water with a small amo\ unt of detergent and rinse thoroughly under the cold water tap. Make sure the filter is completely dry before replacing. Do not expose the filter to sunlight or other sources of direct heat as \ this may cause the filter and frame to warp. When the unit is not being used for long period of time and you want to \ store it, note the following steps: 1. Empty any water left in the water tank. 2. Fold up the power supply cord and put it in the water tank. 3. Clean the air filter . 4. Store in a cool and dry place. ROU TIN E SERVICE AND CLEANING STORAGE
GB 7 When the water tank is full, the unit will switch off automatically and beep 15 times, the LED [2] will light up. - hold t he t op a nd b ottom c entre of t he t an k w ith b oth h an ds a n d p ull it o ut ge ntly . - afte r h avin g e mptie d t he t an k, ge ntly p ush t he t an k ba ck i nto it s p la ce . T he L ED l ig h t w ill g o o ff. W arning: 1 . D o n ot r em ove t he f loa t from t he w ate r t an k. T he t an k f ull s en sor w ill n o lon ger b e a ble t o d ete ct t he w ate r l eve l c orre ctly w ithou t t he f loa t a nd w ate r m ay l eak f r om t he w ate r t an k. 2 . If t he t an k i s d ir ty , w ash it w ith c old or l uke w arm w ate r. D o n ot u se d ete rge nt, s co u rin g pa ds, c hem ic a ll y tr ea te d d ust c lo th s, g aso li n e, b en ze n e, t hin n er, or o th er s olv e n ts , a s t hese c an s cra tc h a nd da mage t he t an k a nd c au se w ate r l e aka ge . 3 . W hen r ep la cin g t he d ra in age t an k, p re ss t he t an k f ir m ly i nto p la ce w ith b oth h an ds. I f t he t an k i s n ot p ositi on ed p rop erly , t he “ TAN K FULL” s en sor w ill b e a cti va te d , a nd t he d eh u m idif ie r w ill n ot op era te . F or the continuous drainage please follow these instructions: 1 . S w itch o ff t he u nit a nd r em ove t he p lug f rom t he e le ctr ic a l o u tle t. 2 . Rem ove t he r ubb er s top per. 3 . Con nect a d ra in t ube ( 10 m m inn er d ia m ete r) on t he d ra in age p ort. 4 . Pl ace t he oth er e nd i n a d ra in . M ake s ure t he t ube i s f re e f r om t wis ts a nd b en ds. Note: The water tank must always be in place, even during continuous drainage.\ E M PTYING THE WATER TANK CO NTIN UOU S DRAINAGEDRAIN A E
Made in P.R.C. AMCOR UK SUPPORT 1. Has the unit been standing upright? (for at least 2 hrs)2. Is the unit plugged into the mains? Is the fuse OK?3. Switch the unit on and wait three minutes to see if the issue is res\ olved.4. Check whether the water tank is full. Please, for your own convenience, make these simple checks before callin\ g the service line. If the unit still fails to operate call: 0871 620 1057 or fill the online form Office hours: 9AM - 5PM Monday to F riday www .amcoruk.com Unit 2, The Nursery, Berristow Lane, South Normanton, Derbyshire, DE55 2\ FX