Page 11
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 11 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990
Page 13
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 13 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Device Unpacking, Verification and Permanent Installation. Unpacking: First carefully unpack the units and verify all the contents are complete, intact and match the items ordered. If there is any discrepancy then please contact Data Delivery Devices LLC for assistance. Quantity Standard Contents (for one RFScada unit) 4ADI-5DO 8ADI-9DO...
Page 14
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 14 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 device transmits data, and the red LED illuminates each time the unit receives data. If the ‘Transmit’ LED and ‘Receive’ LED flash in rapid succession (normal operation) then this device is successfully communicating with another device. For this to occur the main board, including the transmitters and receivers on each unit must all be operating...
Page 15
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 15 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Once the panel has been removed from the cabinet, drill holes large enough (commonly available ‘step’ drills are very useful for these size holes) for the cable clamps or conduit fittings and install the clamps tightly. Remove any dust or particles remaining from drilling, then replace the panel in the cabinet and complete wiring of the inputs, outputs...
Page 16
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 16 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Typical Wiring Installation – 8ADI-9DO (shown with ISM & AO8 Options)
Page 17
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 17 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 Component Identification, Signal and Wiring Reference. 8ADI-9DO Component / Connection Identification RS-232 ModBus Install jumpe rfor RS-485RS-485 Modbus GND Chan 1-4 4-20 mA In Chan 5-8 4-20mA InChan 1-4 Switch InputsChan 5-8 Switch Gnd 4-20mA Transducer +ve supply Relay 8 no nc nc nc nc nc nc nc no no no no no no com com com com...
Page 18
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 18 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 4ADI-5DO Component / Connection Identification
Page 19
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 19 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 RS-232 2-3 RS-485 1-2 Install Pin 1 Normal Operation 1-2 Power Save (relay disabled) 2-3 Install jumper for system relay Pin 1 1 DC Power AC Power AC Line Power Fuse DC Power Fuse Radio Transceiver or Interface Option Board RS-232 Connection RS-485 Connections GND A B System / Modbus LED...
Page 20
RFScada 8ADI-9DO/4ADI-5DO Manual Ver 3.6 Copyright ©2005 Data Delivery Devices LLC Page - 20 – Bartlesville OK Tel 918-335-3318 FAX 918-398-9990 The following chart lists the connections and basic functions of all pins. Refer to the detailed notes for an explanation of each function. Items marked ‘*’ are on the 8ADI-9DO only and do not apply to the 4ADI-5DO. Note that the connector nomenclature is the same for both boards, for example J1 is the AC power connection on both the 4ADI-5DO and the...