Daewoo Rf 420 Service Manual
Have a look at the manual Daewoo Rf 420 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 51 Daewoo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1. Front PCB DISASSEMBLY 2. Door Switch 2-1. RF-420N.. Models No No Inuput a cutter sleeve between Window FCP and Panel F control. ( Be careful not to scratch the surface. ) Unscrew Panel F Control. Lift up the Window FCP. ( Input cutterr deeply to lift up easily.) Pull up the Panel and disconnect the wire connector. Procedure Procedure 3 4 2 1 No No Inuput a thin driver in the right part as above picture. Move switch to left side. And lift up to remove. Disconnect the wire housing.Procedure Procedure 12 20
2-2. RN-420N.. Models 3. Multi-Duct As ( In Freshfood Compartment ) DISASSEMBLY No No Remove top cover hinge screw with (+) driver. Remove the Door Switch from the cover hinge. Separate the Cover hinge by using driver. Disconnect door switch connector. Be careful not to scratch the cabniet surface.Procedure Procedure 4 23 1 No No 1 Remove screw cap with flat driver Unscrew 2 points Disconnect the Lamp & Sensor wire housing.Procedure 3 2Procedure 21
4. Freezer Louver As DISASSEMBLY No No Unscrew the fixing screw to remove the Louver F As Remove 3 screws in order to disassemble Louver F As. Remove the Louver F As pulling the top side. When disassembling check the Knob position. Disconnect Fan motor wire housing. Default position is M 36Procedure Procedure 4 5 2 1 L M H 22
Below process is for RN-420N (Refrigerant type : R-600a) models. Some parts are differ to RF-420N models. ( Hinge Cover, Door Switch, Wire Harness and Button Door Switch. ) When you change door opening direction ( RF-420N models ), please refer page 20 (Door switch Disassemlby) and below. How to change Door opening Dirction (Reversable) No No After hiding door wire harness, remove the button Door Remove top cover hinge screw with (+) driver. Switch and Cover Bushing. After unscrewing the Cover Hinge Harness *T *L, Separate the Cover hinge by using driver. disclose the door wire harness. Reassemble the cover and button door switch. And also assemble the door stopper to opposite side. Remove the Door Switch from the cover hinge. (Which is located the Door under Cap. ) Remove the Middle Hinge. Disconnect all wire connector and hinge. Assemble Cover Bushing & Stopper to the opposite. a. Change the location (screw & division hinge cap ) b. Change the unnder hinge Unscrew the Cover Hinge Harness *T *R location to the opposite. and hide the door wire harness. 510 38 49Procedure Procedure 7 26 1Refrigerator Door Cap Hidden Wire Button Cover Bushing Stopper Freezer Door 23
How to change Door opening Dirction (Reversable) No No Screw the middle hinge to fix the Freezer Door. Connect the wire harness to door swtich. ( Washer should be up. ) ( Be careful the dircetion. ) Also assemble wire cover on the top plate. ( On the rightAssemble Door and hing cover. Change the plate position and separate door switch.Procedure Procedure 15 1214 11 13 24
1. Safety Warning ( R-600a Refrigerant Models Only, RN-420N.. ) This appliance contains a certain amount of isobutane refrigerant (R600a) a natural gas with high environmental compatibility that is, however, also combustible. When transporting and installing the appliance, care should be taken to ensure that no parts of the refrigerating circuit are damaged. Refrigerant squirting out of the pipes could ignite or cause an eye injury. If a leak is detected, avoid any naked flames or potential sources of ignition and air the room in which appliance is standing for several minutes. - In order to avoid the creation of a flammable gas-air mixture if a leak in the refrigerating circuit occurs, the size of the room in which the appiance may be sited depends on the amount of refrigerant used. The room must be 1m3 in size for every 8g of R600a refrigerant inside the appliance. The amount of refrigerant is shown on the identification plate inside the appliance. - Never start up an appliance showing any sings of damage. If in doubt, consult your dealer. 2. Tools How To Charge R-600a Refrigerant 25
3. Process Summary 4. In Detail Precess How To Charge R-600a Refrigerant - Connect the dis- charging hose to the outdoors. - Time : 7 min. 1st Step. R-600a ref. discharging2nd Step. Removing the remaning refrigerant3th Step. Exchanging comp. & dryer / pipe welding 4th Step. Welding coupling pipe5th Step. Vacuum6th Step. Charge R-600a - For removing of remaning refrigerant., connect the discharging hose to the vacuum pump -Time : 10min- Exchange Comp. and Dryer - Welding the Pipe - Copper-Copper : 5% rod - Copper-Steel : 30% rod - Check the vacuum with (mani-polder) gauge - Time : 60~80min- Charging the ref. on POWER ON - Time : 10min Coupling cap and gas charging cap should be seperated before welding. NO. SVC process Image Details 1. Connect the dis charging hos e to the pinc h-plier 2. The outlet of dis c harging hos e s hould be plac ed to the outdoor(window) 1. Fix the pinc h-plier to the c om pres s or c harging pipe. 2. Pinc h-plier s hould not be m oving freely. ※ If that is m oving freely, it would c aus e fire/explos ion as leakage gas in the room . 1. Dis charge the R-600a ref. to outdoor. [Befor c onnec ting the vac uum pum p] ※ It s hould have enough tim e m ore than 7 minutes to discharge. 3Discharging the R-600a re f. 1 2Connecting the pinch -plier & discharging hose Fix ing the pinch-plier & charging pipe OUT DOOR 26
How To Charge R-600a Refrigerant NO. SVC process Image Details 1. Change the c om p. & dryer. ※ You s hould c hec k the com p. s pec . and as s em ble c orrec tly. 1. W eld the eac h pipe. ※ O Copper-Copper welding - 5% rod △ Copper-Steel welding - 35% rod 1. Dec ap the c ouplig pipe c ap and disassemble the vlave assy. ※ If you dont dis ass em ble, the c oupling rubber would be m elted. 8Disassembly of charging v alv e ( Co u pling pipe ) 7 Welding 6Ex changing comp & d r y e r Val v e As s ' y Val v e As s ' y 1. And then, c onnec t the vac uum pum p to the outlet of disc harging hos e 1. Dis as s em be the each pipe (Del-pipe, Suc -pipe, Capi-pipe, Dryer & Hot-pipe) ※V ac um pump s hould be plac ed at t he out door where is able t o c lear air eas ily . ※ It s hould have enough t ime more t han 10 minutes t o dis c harge. ※ Caution ; A part is eas ily dam aged by flam e s o that dis as s em ly should be done c arefully. 4Remov ing the remaining ref. 5Remov ing the pinch-plier & pipe 30% rod 27
How To Charge R-600a Refrigerant NO. SVC process Image Details 1. Reas s em ble the valve as s y with c oupling pipe to c loc kwis e. 2. Connect the blue hos e of the guage to the c oupling pipe and the yellow hose to the vacuum pump. 3. Open the blue guage lever and start the vac uum pum p 1. Be vac uum ed the c yc le with pum p. ※ Tim e : 60~80m in => If the vacuum time is less than 60min, ref. COP & air c oolong would be weak. 1. Chec k the guage : -76 ㎝Hg ※ If the c yc le is not vac uum ed, it would be leak. 1. Chec k the am ounts of R-600a c an with s c ale and disc harge the s urplus ref. ※ Tip of adjus ting. - Can total weight :160g(Can 75g+Ref. 85g) - Adapter : 145g => Total : 305g - The am ounts of c harging : 79g => Dis c harging : 6g => Total : 299g ※ Dis charging is s urely done at the outdoor where is able to c lear air. 13Adjusting the amounts of refrigerants (R-600a can) 11 Vacuum 12 Check Valv e reass' y & guage connecting 10 1. W eld after ins erting the c oupling pipe to the compressor. ※ Us e the wet cloth for preventing the other part of m ac hinery-room from dam age. 9Coupling pipe welding 28
How To Charge R-600a Refrigerant NO. SVC process Image Details 1. Conec t c an adapter to the c oupling pipe. 2. Charge the ref. with open lever s lowly. ※ Refrigerant s hould never leak in the room . 1. On the power of refrigerator and then start to charge the ref. (10min) ※ Charge the ref. until going out the water vapour c on densing on the c an outlet. 1. Chec k the leakage. ※ You m us t rework from Step.1 when the leakage is detec ted. 1. Clean and c lear around the m ac hinery room when the s ervic e is finis hed. 2. Ass em ble the m ac hinery room cover. 17 Finish 14Connecting of coupling pipe & adapta 15 Charging 16 L eakage Test 29