    							FUNCTIONS
    A. “TEMP” Button
     1. Temperature control of Refrigerator compartment
     2. 5 step mode of successive temperature mode
     3. Initial mode by power input: step “3”
     4. Temperature will be set if the button doesn’t get pressed again within 5 sec.
        - Whenever pressing “TEMP” button, setting is repeated in the order of
              “3” → “4” →  “5” → “1” →  “2”  (LED LAMP ON)
    B. Temperature of Refrigerator Control
     1. COMP and FAN will be controlled by the on/off condition of each mode.1
     2. Temperature Difference of Refrigerator each step :
     
     
     3. Temperature of Refrigerator
           at step “3” OFF point: is  -1.4C
     
     4. Refrigerator ON/OFF Temp.
           Difference: 1.7C
    C. “S-COOL” MODE
    1. Press S-COOL SWITCH
        and make S-COOL led lamp on.
    2. COMP & FAN are on
     until R-sensor
         reaches to “Over Refrigeration
         OFF Point”, -7C
    3. After the reach of -7°C , STEP “5” mode continues.
    4. When “S-COOL” MODE (Quick Refrigeration Mode)
        lasts for about 40 minutes, it returns to general
        operation mode.
    D. Temperature of Freezer Control
    -It will be only controlled by using
     “KNOB F LOUVER” in Freezer.
     PCB Control Panel LED
     COMPRESSOR, FAN
    CONTROL OBJECT INPUT
      PCB Control Panel “TEMP” Buttons
     R-sensor  2. Temperature Control of Refrigerator Compartment
    Step      1           2         3          4         5
    ON
    OF Temp
    Dial
    4.3 C
    2.3 C0.3 C
    -1.7 C-3.7 C
    2.6 C
    0.6 C-1.4 C-3.4 C
    -5.4 C “5” “4” “3” “2” “1”
    Temperature Step
    2.0C 2.0C 2.0C 2.0CTemp. Diff. of Each Step
    10
     
    						
    							FUNCTIONS
    Defrost Mode
    A. When total operation time of compressor becomes: 6, 8, 10, 12 hours.
      - any error mode-R1, D1, F3, C1, RT/S, Door SW error- happens.
      - or, running rate of COMP (per 2hrs of total operation time) is more than 80%.
      - or, total door open time is over 3 minutes.
      - or, ambient temperature (RT) is more than 40C.
    B. Even if the above condition “A” is not satisfied,
      - Defrost mode starts immediately when total operation time of COMP is 14hrs.
      - or, defrost mode starts immediately as long as total time (COMP on time + COMP off time) is 60 hrs.
    A. General Defrost Mode
     - How to start: By conditions of defrost
     - Process :
       General operation-
       “PRE-COOL” - Defrost Heater on- Pause (10 min)-General operation
       ; PRE-COOL: When the defrost heater works, the temp. of freezer increases.
             So the COMP works for 25 min before defrost mode.
     - Limited Time of Defrost Heater
       ; 40 minutes: Heater turns off when “D SENSOR” is OPEN or SHORT.
       ; 60 minutes: Heater turns off after maximum 60 minutes.
     - Heater Off: When the temperature at “D SENSOR” is over 10C
    B. Forced Defrost Mode
     - How to start:  by press “TEMP” button for continuously and “S-COOL” button 5 times.
     - Process: same as General Defrost Mode except “PRE-COOL”
        ; Heater is supposed to be on Initial 30 seconds even though the temp. at “D SENSOR” is over 10C.
          (for TEST)
     - How to confirm: by press “S-COOL” button for continuously and “TEMP” button 5 times.
                               And then, the mode displays.
     - Display : led lamps “3”& “S-COOL” on, “4” & ”5” on/off continually
    CONTROL OBJECT INPUT
     Total COMP Work Time  /  COMP Working Rate
    Total Door Open Time  / 
     RT
     3. Defrost Mode
     Conditions of Defrost Mode
     Defrost Mode
    OFF ON OFFDefrostOFF OFF ON
    FanOFF OFF ON
    Compressor
    PauseDefrostPRE-COOL
    11
     
    						
    							A. When initial power input or returning power failure.
        if the temperature at the Defrost Sensor is below 3.5 C, Defrost Mode starts.
        ( It prceeds from PRE-COOL ),  [ PRE-COOL - Heater On - Pause (10min) - Normal Operation ]
    B. Initial defrost mode starts after Prevention of Compressor Restart. ( Refer to function No. 5 )
    FUNCTIONS
     Initial Defrost
     Flow Chart of Defrost Start
    Defrost Mode
    CONTROL OBJECT INPUT
     Total COMP Work Time / COMP Working Rate
     Total Door Open Time   / RT
     3. Defrost Mode
    Comp time >= 2 hours
    Start
    Total time >= 60 hours
    Comp time >= 14 hours
    Comp time >= 6 hours
    Comp Rate >= 80%
    Any Error?
    RT Temp >= 40C
    Total door open time >= 3min?
    ENDDefrosting Start
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    YeYesNo
    No No
    No
    No
    No
    No
    No
    12
     
    						
    							FUNCTIONS
    R-HTR
    COMP
    A. Condition of LOW RT
      - LOW RT Period : RT sensor below 19C
      - When the temperature of RT sensor is over 20C, the system comes to be “General Operation Mode”.
      - When the temp. of RT sensor is between 19°C to 20C, the system keeps the previous mode.
    B. Control
      - When Comp. is on, R-HTR is off.
      - When it passes 6 min after COMP is off, R- HTR is on.
      - COMP can’t be on within 30 min after COMP is off.
           ; COMP doesn’t work at the steps “Heater On” and “Pause”  of  “Defrost Mode”.
                If COMP comes to be off  for “Low Room Temp” in the steps, it seems to take over 30 minutes.
      - Change of “Prevention Time of COMP Restart” :
           If satisfy the following conditions simultaneously, the time changes 6 minutes.
            
    ; Accumulated running time of COMP passes 20 seconds after COMP is off.
            
    ; R-Sensor is more than ‘ON’ Point TEMP.
      - When it is not the mode of LOW ROOM TEMP
          or RT-Sensor is on ERROR (open or short), R-Sensor HTR is off.
      - Function of R-Heater Inspection:
           After initial power is on, R-HTR is on/off 5times for 10 seconds.
      - When Defrost Heater is on, R-Sensor Heater is on
    CONTROL OBJECT INPUT
     RT
    4. Function of Low Ambient Temperature (RT)
    COMP
    COMP. doesn’t work after COMP turns off even though R-sensor is on condition. (This is to protect comp.)
    A. General operation (Temp. at the RT sensor is over 20C): The COMP can’t be on within 6 min.
    B. Operation of LOW RT (Temp. at the RT sensor is below 19C):
         The COMP can’t be on within 30 min.
         (But the COMP can be on after 6min when the doors open more than 20 seconds.)
    CONTROL OBJECT INPUT  5. Prevention of Compressor Restart
    Buzzer
    A. Whenever  “PCB Control Panel” button’s pushed, the buzzer rings.
    B. After 2 minutes power’s on, the buzzer rings 3 times.
    C. Time of Buzzer: Forced Defrost Mode (3 times), Short Circuit Test (1 time)
    D. When door opens, the buzzer rings every 1 minute for 5 minutes.
    CONTROL OBJECT INPUT
    Control Buttons   / Door Switch
    Initial Power Input
    6. Buzzer Sound
    13
     
    						
    							FUNCTIONS
     Buzzer
    A. HOW TO REDUCE
        -   1 min : Click FAST KEY one time on MAIN PCB.
        - 30 min : If you press FAST KEY continuously, you can reduce 30 minutes on each 2.5 seconds with
    buzzer.
    B. Practice Use : Can be applied to reduce needless time on test.
        EX
    ) function of stop for 6 min
    CONTROL OBJECT INPUT
     ”FAST KEY”
    7. Time Reduction
    Display Panel
    A. START : by pressing “TEMP” and “S-COOL” buttons for 5 seconds.
    B. CONTROL :
       - All electronic compartments are off except “Display Panel”.
       - When “DEMO” mode works, led lamps will be on as next steps.
            [ “1”  → “2” → “3” → “4” → “5” → “1”]
    C. CANCEL :
        Push again “TEMP” and “S-COOL” buttons for 5 seconds at “DEMO”, or turn off power and restart.
    CONTROL OBJECT INPUT
     “TEMP” +”S-COOL” Buttons
    8. Demonstration Function
    14
     
    						
    							FUNCTIONS
    Control Resistance of R sensor OFF Point
    A. LOW COOLING OPTION ( Weak Cooling )
        - When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously,
             the following actions are recommended for service.
             
    - Resistance (R47) :  Default resistance (31.4Kohms)
                  - Resistance (R45) :  Cut the “J1” off to reduce basic resistance by 1.5°C. (2Kohms up)
                  - Resistance (R42) :  Cut the “J2” off additionally to reduce basic resistance by 1.5°C. (total 4Kohms
    up)
         R47 = R-SENSOR OFF point
         R47 + R45 = R-SENSOR OFF point - 1.5C
         R47 + R45 + R42 = R-SENSOR OFF point - 3C
     
     
    CONTROL OBJECT INPUT
     ”J1” , “J2”  On Main PCB
     9. Control of R-sensor OFF Point
    R-SENSOR
    J2
    R47(31.4K)
    R45(2K)
    R42(2K)J1
    15
     
    						
    							FUNCTIONS
    B. Prevention OPTION of EXCESSIVE OR LOW COOLING.
     
    ;  The input voltage of MICOM and R-Sensor ON/OFF point by changing J3 & R30.
     
    OPTION 3
    (P63)  26PIN
    CC3 J3 R32 R31
    R30MICOM 5VVa
     Input voltage of MICOM
     R-sensor ON/OFF Point
    CONTROL OBJECT INPUT
      ”J3” & “R30” On Main PCB
     9. Control of R-sensor OFF Point
    +1.7C 5VJ3(CUT), R30(NO USE)0.3C 2.0C 11+1.4C 4V
    J3(CUT), R30 (40.2kohm)0C 1.7C 10+1.1C 3.3V
    J3(CUT), R30 (19.6kohm)-0.3C 1.4C 9+0.7C 2.5V
    J3(CUT), R30 (10kohm)-0.7C 1.0C 8+0.4C 2.0V
    J3(CUT), R30 (6.65kohm)-1.0C 0.7C 7-0.4C 1.6V
    J3(CUT),  R30 (4.87kohm)-1.8C -0.1C 6-0.7C 1.4V
    J3(CUT),  R30 (3.92kohm)-2.1C -0.4C 5-1.1C 1.1V
    J3(CUT),  R30 (2.8kohm)-2.5C -0.8C 4-1.4C 0.8V
    J3(CUT),  R30 (2kohm)-2.8C -1.1C 3-1.7C 0.3V
    J3(CUT),  R30 (680ohm)-3.1C -1.4C 2STANDARD 0V
    - -1.4C 0.3C 1INPUT VOL. (MAIN PCB) OFF ONCompared to
    “STANDARD” MICOM APPLICATION
    TEMP. STEP “3”
    NO
    16
     
    						
    							FUNCTIONS
     Input voltage of MICOM
     R-sensor ON/OFF Point
    C. Changing Difference between R-sensor “On” point and “Off” point.
     
     ; The input voltage of MICOM and R-Sensor ON/OFF DIFF. by changing J4 & R23.
     
    CONTROL OBJECT INPUT
      ”J4” & “R23” On Main PCB
    9. Control of R-sensor OFF Point
    OPTION 2
    (P64)  27PIN
    CC6 J4 R28 R25
    R23MICOM 5VVa
    3.9C 5VJ4(CUT), R23(NO USE)-1.4C 2.5C 113.5C 4V
    J4(CUT), R23 (40.2kohm)-1.4C 2.1C 103.2C 3.3V
    J4(CUT), R23 (19.6kohm)-1.4C 1.8C 92.8C 2.5V
    J4(CUT), R23 (10kohm)-1.4C 1.4C 82.5C 2.0V
    J4(CUT), R23 (6.65kohm)-1.4C 1.1C 72.1C 1.6V
    J4(CUT),  R23 (4.87kohm)-1.4C 0.7C 61.4C 1.4V
    J4(CUT),  R23 (3.92kohm)-1.C 0C 51.1C 1.1V
    J4(CUT),  R23 (2.8kohm)-1.4C -0.3C 40..7C 0.8V
    J4(CUT),  R23 (2kohm)-1.4C -0.7C 30.4C 0.3V
    J4(CUT),  R23 (680ohm)-1.4C -1.0C 21.7C 0V
    - -1.4C 0.3C 1INPUT VOL. (MAIN PCB) OFF ONDIFFERENCE OF
    ON/OFF POINT MICOM APPLICATION
    TEMP. STEP “3”
    NO
    17
     
    						
    							FUNCTIONS
     LED Lamp
    - ERROR DISPLAY
       - To confirm error happens or not, push S-COOL” button for continuously and “TEMP” button 5 times.
       - To stop the Error Display Set, push “TEMP” button 1 times, or wait 4 minutes.
       - After operations back to normal, the displays come to be reset.
    A. R1 ERROR
      (It happens when R-Sensor is OPEN or SHORT)
     -  DISPLAY : STEP “3” LED is on & off continually.
     -  CONTROL :
        ; Controlled by the following condition of RT
        ; When “RT ERROR” happens at the same time, “COMP. ON/OFF Operating Time” is 16min/24min.
                                                                                                                            (Unit : min)
     
     - CANCEL : when R-Sensor is working normally.
    B. RT ERROR
     (It happens when RT-Sensor is OPEN or SHORT)
     - DISPLAY : STEP “2” LED is on & off continually.
     - CONTROL : Delete the conditions of “RT-sensor Control” and operate normally.
     - CANCEL : when RT-Sensor is working normally.
    C. D1 ERROR
     (It happens when D-Sensor is OPEN or SHORT)
     - DISPLAY : STEP “1” LED is on & off continually.
     - CONTROL : Return to next limit defrost time  (40 min)
     - CANCEL : when D-Sensor is working normally.
    D. DR ERROR
       (It happens when the system senses door opens more than 1 hour.)
     - DISPLAY : STEP “2”, “3” LED Lamps are on & off continually.
     - CONTROL : Deletion of function related door switch sensing
     - If door switch (open & close) is sensed, the error is terminated
            automatically
    E. C1 ERROR
       (When D-Sensor is more than -5C, Comp operates over 3 hrs)
     - DISPLAY : STEP “1” & “3” LED Lamps are on & off continually.
     - CONTROL : The system is normally operating
     - CANCEL : When Comp is off, D-Sensor is less than -5C.
    F. F3 ERROR
     Return to next step after max defrost ti me.
     ( 60 minutes )
     6.1- DISPLAY : STEP “1” & “2” LED Lamps are on & off continually.
     6.2- CONTROL : At Defrost Mode, Deletion of “PRE-COOL” Mode.
     6.3- CANCEL : Completion of defrost returned by D-Sensor.
    - If the appliance is normal (no error), just 4 and 5 LED flicker in Error Mode.
    CONTROL OBJECT INPUT
     PCB Control Panel Buttons / Door
    10. Error Display
    6/34
    ~13C
    10/30~19C
    16/24~29C
    20/20
    COMP. Operating TIME
    (ON/OFF)
    29C ~RT sensor TEMP
    - To Confirm Errors:
    Push “S-COOL” for
    continuously and “TEMP”
    button 5 times.
    - The Priorities of Error :
        R1→RT→D1→DR→C1→F3 Defrost
    “1”, “2” F3Cycle
    “1”, “3” C1DR Switch
    “2”, “3” DRD sensor “1” D1RT sensor “2” RTR sensor “3” R1
    ERRORLEDCODE
    flicker
    18
     
    						
    							11. Function Key Summary Table
    ( 1 - 2 - 3 - 4 - 5 - 1 ) Forced Defrost Mode
    Pull Down Mode
    Error Display
    Demo Mode
    Display
     In Error Mode, you can find the current mode ( What mode is operationg ) and what kinds of Error happen.How to terminate Temp + S-Cool button for 5 seconds
    LED Lamps will be on as next steps. Display 4, 5 LED flicker (When no error happens)
    How to enter the Mode Temp + S-Cool button for 5 seconds How to enter the Mode S-Cool + Temp button 5 times
    How to terminate emp button 1 time or after 4 minutes How to terminate After Mode ends ( about 30 hour ) 
    Display 1, S-Cool LED ON (In Error Mode) Display 3, S-Cool LED ON (In Error Mode)
    How to enter the Mode Temp button 30 times How to enter the Mode Temp + S-Cool button 5 times
    How to terminate After Mode ends ( about 1 hour ) 
    FUNCTIONS
    MODE Action Button / Remark 
    19
     
    						