Page 31

30
CONTENTS REMARKS 
4) Control Flow & Timing Chart
①Crushed Ice
②Cubed Ice
③Water 
Delay time : A = 500ms, B = 500ms, C = 2.0s, D = 5.0s
D.P SW 
Gear MotorD.P Lamp
D.P S/V 
(Flap)
D
A
A
C
    D.P SW 
Cube S/V
    D.P S/V
    (Flap)
Gear MotorD.P Lamp
A
C
A
A
B
D
D.P Lamp
D.P SW 
Water S/V
D
A
 from  ManualL 

Page 32

31
5-1. Power Circuit Diagram
5. CIRCUIT OPERATION
- Basic Model
5Vdc 14.5Vdc 12Vdc 310Vac 230Vdc VoltageCE6 CE4 CE3 CE1 MC1E D C B A
Parts
A
- Dispenser Model
B
D
C
E
AB
C
D
E
※Voltage of every part
※Caution : Since high voltage (DC310V) is maintained at the power terminal, please take a measure after more
than 3minutes have passed after removing power cords in the abnormal operation of a circuit.
 

Page 33

32
[F-sensor]
1) It senses the temperature of freezer compartment and control Comp., F-fan ON/OFF
2) How it works;
-19℃ -16℃ -11℃ Working Temp.
≒3.24V ≒9.32㏀ Low ON
≒2.73V ≒2.93V Sensing Voltage≒15.58㏀ ≒15.19㏀ ResistanceHigh OFF Mid OFF Working Point
[R-sensor]
1) It senses the temperature of refrigerator compartment and control R-fan ON/OFF
2) How it works;
3.2℃ 5.2℃ 7.7℃ Working Temp.
≒2.96V ≒23.33㏀ Low ON
≒2.72V ≒2.83V Sensing Voltage≒24.76㏀ ≒24.05㏀ ResistanceHigh OFF Mid OFF Working Point
[D-sensor]...

Page 34

33
CONTENTS REMARKS 
- Dispenser Model
[F-sensor (A)]
1) It senses the temperature of freezer compartment and control Comp., F-fan ON/OFF
2) How it works;
-19℃ -16℃ -11℃ Working Temp.
≒3.24V ≒9.32㏀ Low ON
≒2.73V ≒2.93V Sensing Voltage≒15.58㏀ ≒15.19㏀ ResistanceHigh OFF Mid OFF Working Point
[R-sensor (B)]
1) It senses the temperature of refrigerator compartment and control R-fan ON/OFF
2) How it works;
3.2℃ 5.2℃ 7.7℃ Working Temp.
≒2.96V ≒23.33㏀ Low ON
≒2.72V ≒2.83V Sensing Voltage≒24.76㏀ ≒24.05㏀...

Page 35

34
1. Circuit Diagram
#14≒12V #12≒12V #10≒12V
#14≒0.7V #12≒0.7V #10≒0.7V
IC7 #3≒0V #3≒5.0V Relay 3 Louver HeaterOFF Condition ON Condition
#5≒0V #5≒5.0V Relay 5 D-HeaterRelay 1 Control Mode
Method
IC7IC ULN2004 
Output pin
#1≒5.0V MICOM Port
#1≒0V MICOM Port
CompIC ULN2004
Output pin Control
CONTENTS REMARKS 
5-3. Relay Function
- Basic Model
2. How it works;
IC1
(MICOM)
Comp
D-Heater
Louver HeaterD-Heater Louver Heater Comp R-Lamp F-Lamp 
 

Page 36

35
1. Circuit Diagram
CONTENTS REMARKS 
- Dispenser Model
2. How it works;
#15≒12V #14≒12V #13≒12V #12≒12V #11≒12V #10≒12V #15≒12V #14≒12V #13≒12V #12≒12V #11≒12V #10≒12V
#15≒0.7V #14≒0.7V #13≒0.7V #12≒0.7V #11≒0.7V #10≒0.7V #15≒0.7V #14≒0.7V #13≒0.7V #12≒0.7V #11≒0.7V #10≒0.7VOFF Condition ON Condition
#3≒0V #3≒5.0V Relay 3 H/B Heater
IC8 #7≒0V
IC8 #7≒5.0V Relay 7 Water (Dispenser)#6≒0V #6≒5.0V Relay 6 Water (Ice)#5
≒0V #5≒5.0V Relay 5 Dispenser-Solenoid#4≒0V #4≒5.0V Relay 4 Dispenser-Lamp
#9≒0V #9≒5.0V...

Page 37

36
5-4. Fan Function
- Basic Model
- Dispenser Model
- Vref is the reference voltage for the adjustment of the output voltage by the voltage
distribution of Vs (Maximum output voltage), and the output voltage applied to the fan
is determined by the PWM control using the software. 2. Explanation for the operation
* TA7291P is the drive IC for the only DC motor, and used for control of the fan motor
* One input and output is used for the control of the fan motor
Motor IC No.2 Pin
(R:MT2/F:MT3/C:MT1) Motor...

Page 38

37
6-1. Wiring Diagram
6. DIAGRAM
- Basic Model
 

Page 39

38
- Dispenser Model
 

Page 40

39
6-2. Circuit Diagram of Main PCB
- Basic Model
 
Start reading Daewoo Frs U20 Service Manual