Page 21
20 1. How to start 1) Press “FRZ.TEMP” button 5 times while pressing “REF.TEMP” button at the same time. 2. How to stop 1) Push “FRZ.TEMP” button 1 time. 2) It stops automatically in 4 minutes from the start. 3. All the error codes are reset if they turn to be normal. 4. Error display INPUTCONTROL OBJECT CONTENTS REMARKS Temperature Control ButtonsLamp LED of Inner control (Full down mode and forced defrost mode are displayed while pressing “REF.TEMP” button at the error display mode) REF. LED “1” is...
Page 22
21 5. Control way of Errors (if any) 1) “F-sensor” error Cause : F-sensor open or short Control : Condition of ambient temperature How to reset : If F-sensor is normal, the error is terminal temperature. CONTENTS REMARKS 2) “R-sensor” error Cause : R-sensor open or short Control : Condition of ambient temperature How to reset : If R-sensor is normal, the error is terminal temperature. 3) “RT-sensor” error Cause : RT-sensor open or short (full down) Control : Normal operation, deletion of control by...
Page 23
22 1. How to start 1) Under “LOCK” mode, press “SUPER FREEZER” button 5 times while pressing “FREEZER SET” button at the same time. 2) The front CLED displays as the right diagram shows ( [Ex.] Time Display of 0003 signifies 3 minutes of power on time.) 3) Press “FREEZER SET” button and the following value is displayed successively. ①Time ②F-Sensor temperature ③D-Sensor temperature ④R-Sensor temperature ⑤RT-Sensor temperature ⑥P Factor display (Refer to water supply mode of automatic icemaker) ⑦Filter...
Page 24
23 1) “F1” error Cause : F-sensor disconnection or short Check point : Measure the resistance between both terminals after separating CN8 (or CN15) of the Main PCB. (Refer to the 5-2.) If F-sensor is disconnected or shorted , change the F-sensor in the freezer compartment. How to reset : If F-sensor is normal, the error is terminal temperature. CONTENTS REMARKS 2) “R1” error Cause : R-sensor disconnection or short Check point : Measure the resistance between both terminals after separating CN7 (or...
Page 25
24 9) “EI”ERROR Cause : I-SENSOR disconnection / short Check point : Measure the resistance between both terminals after separating CN11 of the Main PCB. (Refer to the 5-2.) If F-sensor is disconnected or shorted , change the I-sensor in the automatic ice maker. CONTENTS REMARKS 10) “EF” ERROR Cause : When Flow-sensor ERROR (There is no Pulse during some time) The number of pulse signal is below 10 by 1 sec during water supply. Check point : Water supply line 13) “Ea” error Cause : Malfunction of ice...
Page 26
25 Element A/S Function INPUTCONTROL OBJECT CONTENTS REMARKS Each buttonResistance of R-sensor Mid ON/OFF Point “REF.TEMP”+ “FRZ.TEMP” 5 times Error display“FRZ.TEMP”+ “FRZ.DOOR” OPEN/CLOSE 5 times Demo function“REF.TEMP”+ “FRZ.DOOR” OPEN/CLOSE 5 times Pull Down“FRZ.TEMP” + “REF.TEMP” 5 times Forced Defrosting 1. All the modes are started “LOCK” mode (except “FILTER RESET” mode) 2. Element A/S Function INPUTCONTROL OBJECT CONTENTS REMARKS Each buttonResistance of R-sensor Mid ON/OFF Point “WATER/ICE” +...
Page 27
26 1. Filter Exchange Information : Record as a real-time from the point of power input 2. P Factor (Information about Ice Maker) INPUTCONTROL OBJECT CONTENTS REMARKS None 1. F-FAN, R-FAN, C-FAN INPUTCONTROL OBJECT CONTENTS REMARKS Full ice sensing switch Ice Maker Lock Sensors Ice separating motor 1. Flow of ice making 1) Press TEST switch under the Icemaker for more than 1 second and test starts. * Test mode starts from ice separating mode. * In case test switch has an error of short, test is done...
Page 28
27 CONTENTS REMARKS 2) With the initial power input, Ice tray turns to be horizontal and ice making mode starts. 3) Control of water hose heater * Heater is always ON if RT-sensor has an error or RT is below 15 degree. * Heater is always ON for 60 minutes (max. Limit time) if Flow-sensor has an error 4) Water supply stand-by Condition : if ice is sensed full Operation : proceeds to Ice making mode (Ice separating and water supply Modes stop) 5) Crusher Function It stops operation when freezer door is...
Page 29
28 CONTENTS REMARKS 3. Ice separating (drop) mode CCWCWSTOPCWmotor revolutionlevel SW status of ice tray Horizontal position Ice separation start 8~11secMAX1.1sec 8.5~12.2sec 0.2sec normal level SW level SW error1.1 sec 11 sec 10 sec 1) Time of each zone used to verify level switch error 2) The rotation of motor is sensed at each zone 3) In case of level switch error, ice separation is done by time. 4) If ice separating motor has error, the mode stop. 4. Water supply mode START Water supply valve ON...
Page 30
29 CONTENTS REMARKS 1) Water supply valve is open when water supply mode starts after separation of ices. 2) Water is supplied by time in case sensor has error. 3) Factor valve is variable which can be useful in AS action ①Water flow pulse is set to 238 if flow sensor is in normal condition. (If water is supplied by time, maximum water supply time 165 seconds) ②In case water flow sensor has error, water time is 5.5 seconds. 5. Water supply check mode 5 minutes after water supply the status can be...