Page 31
30 OPERATION AND FUCTIONS CONTENTS REMARKS 1. Conditions to turn on LCD Light 1) Power input (plugin) 2) When any button on the panel is pushed, first the back light turns on, then button control is done. 3) When F/R door is open, the light turns on. 2. Conditions to turn off the light 1) The back light turns off 10 seconds after F/R door is closed 2) 1 minute after button control Explanation After Delivery INPUT Control Object FREEZER SET. button REFRIGERATOR...
Page 32
31 OPERATION AND FUCTIONS Delay Function of Electric Components INPUT Control Object COMP ON/OFF COMP F-FAN CONTENTS REMARKS 1) F-fan delay by comp. ON/OFF F-fan is ON/OFF 1 minute after comp. is ON/OFF. 2) F an Delay and Priority R F A N ON condition 0. 5s ec . ON ON ON 1. 0s ec . 1. 5s ec . F FA N C F A N OF F OF F OF F 3) F / R-fan delay by door open/close for easy door opening. Inspection : checkup door opening 2 hours after initial start. F irst R is ON, 1...
Page 33
32 OPERATION AND FUCTIONS Home Bar (Refreshment Center) Heater INPUT Control Object None COMP CONTENTS REMARKS It is linked with comp. Control of Interior Lights INPUT Control Object Refrigerator Door Freezer Door Home-Bar Door (Refreshment Center) COMP CONTENTS REMARKS 1) Control of Refrigerator Compartment Lights R lights turn ON/OFF by R-door switch (ON/OFF). 10 minutes after sensing door open, the lights turn off automatically though door close is not sensed. 2)...
Page 34
33 OPERATION AND FUCTIONS Regulation of R-sensor OFF Point INPUT Control Object J18, 22 on Main PCB Resistance of R-sensor Mid OFF Point CONTENTS REMARKS Regulation of R-sensor OFF point (1.5degree DOWN) In case refrigeration of refrigerator is weak or insufficient, take the following action. R-SENSOR OP1- 1-2 R26 R70 R71OP OP1- 1-1 R26 : R-SENSOR standard resistance in normal mode (31.4K ) R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K)...
Page 35
34 OPERATION AND FUCTIONS Regulation of R-sensor OFF Point INPUT Control Object J18, 22 on Main PCB Resistance of R-sensor Mid OFF Point CONTENTS REMARKS Regulation of R-sensor OFF point (1.5degree DOWN) In case refrigeration of refrigerator is weak or insufficient, take the following action. R-SENSOR OP1-2 R26 R70 R71OP OP1- 1-1 R26 : R-SENSOR standard resistance in normal mode (31.4K ) R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) R71...
Page 36
35 OPERATION AND FUCTIONS Input Control Object Fully Ice Sensor Ice Maker Lock Ice seperation Motor CONTENTS REMARKS 1-1. Ice Maker FLOW RETURN ICE Making ICE Drop Supply water into the Ice maker Check water input is normal. 1) By Pushing of Ice Maker ASSY TEST S/W (Over 1 Sec.): TEST Mode Convert (Ice Drop Mode Start with Test Mode Proceed) 2) Ini tial Power inpu t => Ic e Make r is horizonta l => Proc eed from Ice maker Mode 3) Water-Input hose HTR Control...
Page 37
36 OPERATION AND FUCTIONS CONTENTS REMARKS 1-2. Ice Maker M ODE NO NO YES YES NO YESYES NO 1) 2) 3) I-Sensor Error: Ice Maker Complete after 4.8HR I-S is -12.5 and below after 130 min.=> Ice maker complete Although I-S isnt -12.5 below for 130 min, I-S maintains -9.5 below continuously => Ice maker comlpete 2. Ice Drop MODE status Ice tray level level normal level 8-11 Max 1.1 8.5-12.20.2 10 11 1.1 1) Each Section’s Time used in S/W ERROR Confirm 2) Ice Drop...
Page 38
37 OPERATION AND FUCTIONS CONTENTS REMARKS 3. Water-Input MODE N Y Flow-Sensor Error mode START Inlet value ON Water input pulse Count=0 Y Y N N Y N 1) Convert of Water-Input Mode After Ice Drop: Water-Input Valve Open. 2) Flow Sensor Error: Water-Input is Controlled by Time 3) Veriable Factor Value : Using for A/S Steps (Water input by Time -: Maximum Water Inut Time => 15 sec. 4. RT-S 7 ~13 ~19 ~29 ~39 39 I-S -10 -9 -8 -7 -6 -5 Flow Sensor Normal...
Page 39
38 OPERATION AND FUCTIONS Dispenser Control Function Control Object Dispenser SW Water/Ice Button Lock Ice Maker Button Freezer Door SW Dispenser Lamp Crusher Motor Flat Solenoid Crusher Solenoid Dispenser Water Valve Contents Remark 1) Water/Ice Selection Button Progress : Water Ice Cube Crushed Ice Water 2) Lock Ice Maker Button Start by pushing Lock Ice Maker button Lock Icer Maker is ON, The Icon & Box of Cube Ice/Crushed Ice disappear,...
Page 40
OPERATION AND FUCTIONS Contents Remark 4) Control Flow & Timing Chart 4-1)Crushed Ice D.P SW (In) D.P SW (In) Crusher Motor Crusher MotorD.P Lamp D.P Lamp D.P S/V (Out)D A A C 4-2) Ice Cube D.P SW (In) D.P SW (In) D.P S/V(Flap) D.P S/V(Flap) Cube S/V Cube S/V Gear Motor Gear MotorD.P Lamp D.P Lamp A C A A B D 4-3) Water D.P Lamp D.P Lamp D.P SW (In) D.P SW (In) Water S/V Water S/VD A Delay Time : A = 500ms, B = 500ms, C = 2.0s D = 5.0s 39