      REMARKS
      1. 
    Conditions to turn on  LCD Light 
       1)  Power input (plugin)  
    2)  When any button on the panel is pushed, first the back light turns on, t\
    hen 
    button control is done.  
       3)  When F/R  door is open , the light turns on.  
     
     2.  Conditions to turn off the light  
        1)  The back light turns off 10 seconds after F/R door is closed   
    2)  1 minute after button control     
    Explanation After Delivery INPUT
      Control Object
      “
    FRZ SET. ” button  
    “ REF SET. ” button  
    P ower Cord   Electrical 
    components  and LCD  CONTENTS
      REMARKS
       
    1. 
    Start  
        Push  “REF SET. ” button for 3 seconds within 10 seconds just after power 
    input.  
     
    2.  Control   
     1)  Electric al components  are OFF for 3 hours.  
     2) D isplay operates in normal way.    
     
    Prevention of Compressor Restart  INPUT
      Control Object
      None
      Comp.   CONTENTS
      REMARKS
      C
    omp. does not start again for 6 minutes though F -sensor is ON.   6min. delay    
     
     
     
     
     
     
     
     
     
     
     
     
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 31 -
     
    						
    							Dela y  F unctio n o f E le c tr ic  C om ponen ts 
    IN PU T C on tr o l O bje ct 
    C O M P O N/O FF C O M P 
    F-FA N 
    C O NTE N TS R EM ARKS 
     
    1) F-fa n d ela y b y c o m p. O N/O FF 
    -> F-fa n  is O N/O FF 1 m in ute  a fte r c o m p. is  O N/O FF. 
     
     
     
    2) F an D ela y a nd P rio rit y  
    R  F A N
    O N  c o ndit io n
    0.5 se c.
    O N
    ON
    ON1.0 se c.
    1.5 se c.
    F  F A N
    C F A N
    O FF
    O FF
    O FF
     
     
    3) F /R-fa n d ela y b y d oor o pen/c lo se  fo r e asy d oor  
     - > In sp ectio n : c h ecku p d o or o p ening  2  h ours  a fte r in it ia l  s ta rt 
       - > F ir s t  R  is  O N, 1  s e co n d la te r F  is  O N to  p ro te ct D C fa n  a gain st o ve r c u rre nt a t 
    in it ia l  s ta rt.  
     
    D O OR
    R F A N
    O PEN
    C LO SE
    20.5  s e c.  ( 0 .5 se c.
    fo r fir s t  2  h rs .)
    2 1se c.  ( 1 se c.  fo r fir s t  2  h rs .)
    O N
    O FF
    O N
    O FF
    F F A N
      
     
     
     
     
     
      
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    - 32 -
    1Min1Min
     
    						
    							 
    Home Bar (Refreshment Center) Heater (FR-S580CR MODEL) INPUT
      Control Object
      None
      COMP  CONTENTS
      REMARKS
      It is linked with comp.
       
     
    Control of Interior Lights INPUT
      Control Object
      R
    efrigerator Door  
    Freezer Door  
    Home -Bar Door   
    ( Refreshment Center ;  FR-S580CR)   COMP
      CONTENTS
      REMARKS
      1)
     Control of  Refrigerator Compartment Lights  
    R  lights tu rn ON/OFF by R -door switch (ON/OFF).  
       * 10 minutes after sensing door open, the lights turn off automatically thou\
    gh 
     door close is not sensed. 
     
     
    2 )   Control of  Freezer Compartment Lights  
      F  lights turn ON/OFF by F -door switch (ON/OFF).  
     
     
     * 10 minutes after sensing door open, the lights turn off automatically though 
    
    door close is not sensed. 
     
     
    3 )   R -lights ON/OFF by  Home -B ar  door opening  
        R-lights turn ON for 1 minute after sensing  HOME-BAR  switch open.  
       (If the switch is pushed again within 1 minute,  the light turns on another 1 
    minute.)  
       
     
    Demonstration Function INPUT
      Control Object
      “
    LOCK ” button  
    “ REF SET. ” button  
    “ SLEEP ” button   COMP
     
    F -FAN  
    R -FAN   CONTENTS
      REMARKS
       
    1. 
    Start   
        1) Set  “LOCK ON ” first.  
    2) Push  “SLEEP ” button 5 times while pushing  “REF SET. ” button simultaneously.  
     
    2. 
    Control  
     1)   All other electrical components are OFF except for  F-fan /  R-fan.   
    2)   F an Control  
     
     DOOR OPEN
     -> FAN ON / DOOR CLOSE -> FAN OFF 
    
     3) 
    D
     isplay
     
     :
     
     Normal mode
     
     (3.8
    sec.
    ) -> SPEED(3sec.) -> Silent mode(3sec.) ->
     Sleep m
    ode (3sec. ) 
    3.  Stop or Termination  
     1)  During Demo mode push  “SLEEP ” button 5 times while pushing  “REF SET. ” 
    button simultaneously.  
     2)  Power in again.  
           
     
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 33 -
     
    						
    							 
    Regulation of R-sensor OFF Point INPUT
      Control Object
      J18, 22 on 
    Main  PCB   Resistance of R-sensor Mid  OFF Point  CONTENTS
      REMARKS
       
     a. Regulation of R-sensor OFF point (1.5degree DOWN) 
     b. In case refrigeration of refrigerator is weak or insufficient, take the \
    following action. 
    R-SENSOR
     OP1-2
    R26
    R70
    R71  OP1-1  
    a. R26 : R-SENSOR standard resistance in normal mode (31.4K ) 
    
     
     b. R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K) 
     
     c. R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K) 
     
     
      R26 = Mid OFF  point  
      R26 + R70 =  Mid OFF  point  - 1.5 deg  
      R26 + R70 + R71 =  Mid OFF  point  - 3.0 deg    
     
    Summary of Function  CONTENTS
      REMARKS
        
     
    * How to start function modes 
    * All the modes are started with “LOCK ON”  except for “explanation after delivery & installation”.    A/S 
    forced defrosting  “FRZ SET. ” +   “REF S ET.” 5 times       D
    emonstration   “REF SET. ” +   “SLEEP ” 5  times      Explanation after delivery & 
    installation
      “
    REF SET. ” for 3 sec.  Right after first power in      ERROR 
    display  “REF SET. ” +  “LOCK ” 3  times      
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 34 -
     
    						
    							 
     MICOM Circuit 
      Power 
      Circuit 
     
     
     
    DC Output Power (Voltage)    Point
      Oscilloscope 
     Measurement   Remarks
       
       
    *  DC  output  
     
    15.7V  
    11.96V  
       
     
     
     
     
     
     
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 35 -
     
    						
    							 
     SMPS Movement Wave 
        Drain to Source Break
     Voltage 
     Point
      Oscilloscope  Measurement   Remarks  SMP
    SIC 
    PIN
     
    1,2     
      *Voltage between 
    DRAIN
     and 
    SOURCE  :  
    below  650V   
       OVP(Overvoltage Protection) Wave at power input 
    
    Point
     
    Oscilloscope  Measurement   Remark
      SMPS  
    IC PIN  
    3,4
        *Minimum 
    standard 
    voltage at  OVP 
    start :   
    23.2V    
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 36 -
     
    						
    							 
         Initial Power Wave of Switching Power IC 
    
    Point
     
    Oscilloscope Measurement   Remark
      SMPS  
    IC PIN  
    3,4
         
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 37 -
     
    						
    							 
     
    Sen so rs 
    C ir c u it D ia g ra m 
     
     
      F unctio n o f  E ach  S en so r 
    [  F-se nso r ] 
    1 ) I t s e nse s t h e t e m pe ratu re  o f f r e eze r c o m partm ent a n d c o n tr o ls  Co m p., F-fa n O N /  O FF. 
    2) H ow  it   w ork s ; 
    W ork in g P oin t Low  O N M id  O FF H ig h  O FF 
    W ork in g Tem p. -11.0  C  -20.0  C  - 26.0  C  
    R esis ta nce  14.74  k   22.33 k    30.92  k  
    S ensin g V olt a g e  3.50 V  3.00 V  2.14 V 
     
    [ D-se nso r ] 
      ->  It s e n se s r e tu rn  p oin t  o f  d efr o stin g  h ea te r. 
    W ork in g P oin t R etu rn  p o in t  o f  d efr o stin g h ea te r 
    W ork in g Tem p. 10 C   
    Resis ta nce  19.53 k   
    S ensin g V olt a g e  3.1 V
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    - 38 - 
    =..=..=..
    =..
     
    						
    							 
     
    [ R-s e nso r ] 
    1 ) I t s e nse s t h e t e m pera tu re  o f r e fr ig era to r c o m partm en t a nd  c o n tr o ls  R-fa n O N /  O FF. 
    2 ) H ow  it   w ork s ; 
    W ork in g P oin t Low  O N M id  O FF H ig h  O FF 
    W ork in g Tem p. 2.65  C  0.3  C  -1.7 C   
    Resis ta nce  26.88  29.34 32.00 
    S ensin g V olt a g e  2.90V  2.81V  2.74V 
    * In  c a se  r e fr ig e ra tio n o f  r e fr ig era to r c o m pa rtm en t  is  p oo r o r insu ffic ie nt  th ou gh  c o m p.  a nd  R-fa n o pera te  in  
    n orm al  w ay ;  
    1 ) C ut J 1 8 o n  M-P C B,  th en te m p.  is  lo w ere d -2 C t h an [M id  O FF p oin t]. 
    2 ) I n  a ddit io n  t o  1 ) a ctio n , c u t J 2 2 o n M-P C B,  th en th e te m p.  is  lo w ere d –1  C  m ore . 
     
    Rela y F unctio n  
    C ir c u it  D ia g ra m 
     
     
    H ow it  w ork s ; 
    O N C ondit io n O FF  C on dit io n C ontr o l C ontr o l  M eth o d M IC O M  Po rt IC 3 O utp ut P in M IC O M  Po rt IC 03 O utp ut P in 
    C O M P RELAY # 163.7 V #  140.7 V #  160V #  1412V 
    F-LA M P RELAY # 153.7 V #  130.7 V #  150V #  1312V 
    H B-HTR R ELAY # 143.7V #  120.7 V #  140V #  1212V 
    H TR R ELAY # 133.7 V #  110 .7 V #  130V #  111 2V 
    R-LA M P RELAY or S SR # 123.7 V #  100.7 V #  120V #  1012V 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    - 39 -
    kkk=..=..=..
    =..=..=..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
    =..
     
    						
    							Fan  F un ctio n  
      H ow  It   W ork s  ; 
    O N C ond it io n O FF  C on dit io n 
    M ICO M  Po rt M IC O M  Po rt C ontr o l 
    O bje ct 
    C ontr o l 
    M eth od 3 1 32 33 IC  Co lle cto r 3 1 32 33 IC  Co lle cto r 
    Low  (1 0V ) 
    opera tio n 5V 0V 0V 1 0.3 5V 0V 
    M id  (1 2V ) 
    opera tio n 0V 5V 0V 1 2.1 9V 0V F-F A N 
    H ig h (1 4 V ) 
    opera tio n 0V 0V 0V 1 4.3 8V 
    5V 5V 5V 
    0V 
     
    O N C ondit ion O FF C ondit io n 
    M IC O M  P O RT M IC O M  Po rt C ontr o l 
    O bje ct 
    C ontr o l 
    M eth od 3 9 40 41 IC  Co lle cto r 3 9 40 41 IC  Co lle cto r 
    Low   (1 0V ) 
    opera tio n 0V 5V 5V 1 0.3 8V 0V 
    M id  (1 2V ) 
    opera tio n 5V 0V 5V 1 2.2 4V 0V R-F A N 
    H ig h (1 4 V ) 
    opera tio n 5V 5V 5V 1 4.4 2V 
    0V 0V 0V 
    0V 
     
    O N C ond it io n O FF C ondit io n 
    M IC O M  Po rt M IC O M  Po rt C ontr o l 
    O bje ct 
    C ontro l 
    M eth od 3 7 38 IC  Co lle cto r 3 7 38 IC  Co lle cto r 
    H ig h (1 4 V ) 
    opera tio n 0V 0V 1 4.5 4V 0V 
    C-F A N Low  (1 0V ) 
    opera tio n 5V 0V 1 0.4 5V 
    5V 5V 
    0V 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    - 40 -
     
    						