    SILENT (Silence Mode) INPUT
      Control Object
      1. CDS SENSOR
      5.
     COMP  
    6.  R -FAN  
    7.  F -FAN  
    8.  CUSTOM -LCD   CONTENTS
      REMARKS
       
    1.
     Purpose of Silence mode   
    To reduce refrigerator noise at night by decresing fan RPM to a minimum d\
    egree  
       
    2.  Condition  to start 
     1)  The optical o r light sensor in top middle of control panel senses surround light and \
    Silence mode starts if the amount of light sensed is below the standard \
    value for 
    more than 1 minute.  
    ( The mode does not start for initial 240 minutes to prevent down of cooli\
    ng 
    perfor mance.)  
     a. Standard value to decide ‘night’ : below 5~ 7 Lux (optical sensor surface) 
     b. Standard value to decide ‘daytime’  : above 4~16 Lux  
     (optical sensor surface)
     
     
    3.  Control Method  
    Control Mode  F-FAN   R-FAN   C-FAN   Normal   10V
      10V  10V  Silence  
    Load
     
    Control   12V
      12V  10V   
     
    4. 
    Termination Condition  
    The mode stops if lux value is above the standard for more than 1 minute\
    .  
       
     
    Control of Each Mode INPUT
      Control Object
      1.
     CDS SENSOR  
    2.  R SENSOR  
    3.  F SENSOR        1. F
    -FAN (14V, 12V, 10V)   CONTENTS
      REMARKS
       
    *  Control of Silence mode : operation mode when the optical sensor feels that it is 
    
    night  
     
    * Normal control : daytime operation mode  
     (Refrigerator noise is relatively low at daytime.)
     
    * Load control  : operation mode when inside temperature goes up due to an 
    increase of load
     ( foods ) or frequent door openings  
        
     
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 21 -
     
    						
    							 
     
    CO NTE N TS R EM ARKS 
     
    1. F an  volt a g e o f e ach  c o ntr o l  m ode 
     
    2. C ontr o l  a gain st  ( u nder) lo ad ( L oad C ontr o l) 
    1 ) P urp o se : To  re sto re  F /R-te m pera tu re  w hic h  h a s ris e n b y lo a d (m uch  fo od s in  o r 
    fr e qu en t  d oo r o pen in gs) a s s o o n a s p ossib le 
     
    2 ) Dis p la y :   S PEED  lig hts  u ntil  t h e m ode a nd s p eed ic o n s flic ker. 
     
    3 ) C ondit io ns to  s ta rt ( fr o m  b oth  N orm al  a nd S ile nce) 
     a .   F  o r R  d o or o p en tim e e xce ed s 3 0 s e co n ds a t  a  tim e - >  F re e ze r a nd  R efr e ge ra to r   
     
     
    lo ad c o ntr o l  s ta rts  r e sp ectiv e ly .
    b . O ve r [F-s e nso r O n P oin t +  5b .   d eg re e] - >  F
     
    lo a d c o ntr o l 
    c. O ve r [R-s e nso r O n P oin t +  5 d egre e] - > R lo ad  c o n tr o l 
     
    4 ) C ond it io n s t o  a vo id  lo ad  c o ntr o l 
     a . In it ia l  o pera tio n ( ru ght a fte r p ow er in put)  o f r e fr ig era to r 
     b . Ju st  a ft e r P re-co ol,   He ate r d efr o sting,  P ause , D efr o stin g  c ycle 
     
    5 ) C ontr o l  M eth od 
    5-1 ) C ontr o l  m ode  b y F /R-d oor o pen t im e (o ve r 3 0 s e co nd s) 
     -> F /R-fa n w ork s b y 1 4 V r e sp ectiv e ly. 
    5-2 ) C ontr o l  m od e b y [F-se n so r O n P oin t +  5 d egre e ] 
       -> F-fa n w ork s b y 1 4V. 
    5-3) C ontr o l  m od e b y [R-se n so r O n P oin t +  5 d egre e] 
       -> R-fa n w ork s b y 14V. 
      * C-fa n w ork s b y 10V a s n o rm al. 
     
    6 ) C on dit io ns to  sto p 
    a. T he m ode w ork s fo r 2 0 m in ute s.  
      (If a noth er c o ndit io n h appens a t th e e nd o f th e m ode, it  s ta rts  a gain .) 
     b . W hen it  r e ach es to  [F-senso r O ff p oin t],  F-fa n lo ad  c o n tr o l  m ode  s to ps. 
     c . W hen it  r e ach es to  [R-se nso r O ff p oin t],  R-fa n lo ad  c o ntr o l  m ode s to ps. 
    C ontr o l  M od e F-F A N R-FA N C-FA N 
    N orm al 12 V 12V 
    N orm al 14 V 14V Loa d C on tr o l S ile n ce 1 2 V 12V 
    S ile n ce N orm al 10 V 10V 
    N orm al 10 V 10V S le e p M od e2 L o ad c o ntr o l 12 V 12V 
    10V 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    - 22 -
     
    						
    							 
    CONTENTS
      REMARKS
       
    3. 
    Control  Time Chart  of Each  Mode  
       1)  Start & stop of load control mode (Normal Control)  Door
    F/S
    F Fan
    R/S
    R Fan Door Open
    30 sec. after Open
    Load Mode Start Frz. Load Stop Rez. Load Stop On + 5deg
    On + 5deg Frz. Overload Input
    Frz. Start Condition Frz. Stop ; 
    after 20min. 20min.
    20min. Ref. Load14V
    14V
    12V
    12V   
    2) 
    Start & stop of load control mode (Silence Control)  Door
    F/S
    F Fan
    R/S
    R Fan Door Open
    30sec. after openLoad Mode StartRef. Load StopFrz. Load Stop On + 5deg
    On + 5deg
    Frz. Overload InputFrz. Load Start
    Frz. Stop Condition ; 
     after 20min.20min.
    20min.
    Ref. Load 12V
    12V
    10V
    8V     
     
     
    3)  Start &  stop of load control mode (Normal defrosting control)  F/S
    F Fan R/S
    R Fan
    Defrosting StartCondition to start Load 
    Mode, but avoided 
    buring defrosting modeRef. Load Stop On + 5deg
    Normal Operation
    20min.
    Ref. Load Mode
    14V
    12V
    8V
    HTR
    Comp  
     
       
     
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 23 -
     
    						
    							 
    CONTENTS
      REMARKS
       
    4. 
    Flow Chart of Load Control Mode  
     
      Sart
    F/R door open time is over 30 sec. ?
    F/S ON + 5deg?
    R-sensor ON + 5deg?Fan RPM
          F Fan : 12V
          R Fan : 12V
          C Fan : 10V Fan RPM
              Normal    Overload
    F Fan :  10V         12V
    R Fan :  10V         12V
    C Fan :  10V         12V Overload of both
    compartments Y
    N
    Freezer
    Compartment Overload Refrigerator
    Compartment
    Overload Y
    N
    Y
    N
    F load control ;
    over 20 min. ? F-sensor OFF point ?Overload mode control Overload mode ?
    Normal mode
    control N
    F load control mode stop
    R-sensor OFF point ? R load control mode
    stop EndLoad control is avoided ?
    N Y
    R load control ;
    over 20 min. ? Y
    Y
    YN
    Y
    N
    N
    Y
    NControl Mode
    Normal 240 minutes ?N
    Silence
     
       
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     - 24 -
     
    						
    							 
    Defrosting Cycle INPUT
      Control Object
      1. 
     Total comp.  work time  
    2.   Comp.  work rate  
    3.   RT  temperature  
    4.   Total door open time   1. 
    Defrosting Mode   CONTENTS
     
    REMARKS  
    1. 
    Conditions to start  defrosting cycle 
      1)   Total comp. work time  : 6, 8, 10 hours 
      2)   C omp. work rate  (by the 2 hours ) :  over  65% 
      3)   Total door open time  : 3 minutes   
    (Any door  - F or R  – open time is over 3 minutes.)  
      4)   Total time of [comp.  ON + comp.  OFF]  : 60  hours  
      5)
     
      Ambient temperature
     :
     
     over 
    3
    5C 
       6) 
    Any error mode  : R1, F1, D1, F3, RT/S, Door -switch  
     
     2.  Conditions to start defrosting mode   
    1)  The mode starts in the following conditions ;  
    a. Any error happens when total comp. work time is 6 or 8 or 10 hours. 
    b. Comp. work rate by the 2 hours is over 65%. 
     c. Total door open time is over 3 minutes.  
     (Any door 
    - F or R  – open time is over 3 minutes.)  
    d. Ambient temperature is over 35C 
    2)
     Defrosting mode starts unconditionally as long as total comp. work time\
     is 10 hours,   
    even if the above conditions
     (a~d  ) are not satisfied.  
     3) 
    Defrosting mode starts immediately as long as total time of [comp. ON + \
    comp. OFF] is 
    over 60 hours, even if the above 1) and 2) conditions are not satisfie\
    d.   
     
     
     
     
     
     
     
     
     
     
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 25 -
     
    						
    							 
    CONTENTS
      REMARKS
       
    3. 
    Flow Chart of Defrosting Start  
      Start
    Ambient temp. is over 35C ?Comp. work time is over 10 hours ? Total time is over 60 hours ?
    Comp. work time is over 6 hours ?
    Any error ?Comp. work rate is over 65 % ?
    EndDefrosting mode starts. Yes
    Yes
    Yes
    Yes
    Yes
    Yes No
    No
    No
    No NoNo
    Comp. work time is over 2 hours ?
    Total door open time is over 3
    minutes ? YesYes
    No
    NoComp. work time is over 8 hours ? No
    No
     
         
     
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 26 -
     
    						
    							 
    Defrosting Mode INPUT
      Control Object
      1. 
    Defrosting Cycle   1. COMP
     
    2. F -FAN  
    3. R -FAN  
    4. HEATER   CONTENTS
      REMARKS
       
    1. 
    Defrosting Mode  
      1) Time ; 50 minutes  
    2) C omp. /  F-fan :  ON 
    R -fan  : Control  
    H eater : OFF  
    3)  If F
    -
     senso
    r < - 27C, PRE-COOL becomes OFF. 
    
     
     
    
                            
     
     1) 
    If D-
    sensor > 10C, Heater becomes OFF. 
     2) 
    In case of Heater return by time limit of  40 or  80 min  
    (F3 -E rror ) 
    3)  Heater is ON for 30 minutes (time limit) in case of  D-
    sensor error.  
    4)  Time limit  
     a. 30 seconds : Heater is ON regardless of D-sensor 
     temperature right after defrosting start.
     
     b. 30 minutes : in case of D1-Error 
     c. 80 minutes : in normal control state 
      
    1) 
    Time : 7 minutes  
    C omp.,  F-fan,  R-fan , Heater :  OFF 
     
     
    1)  Time :  5 minutes  
    C omp. :  ON 
    F/R -fan, Heater : OFF  
     
    * Output control and time limit of each defrosting mode 
      
      PRE
    -COOL   H
    eater Defrosting   Pause
      F
    an  Delay
      COMP
      ON  OFF  OFF  ON  F
    -FAN   ON  OFF  OFF  OFF  R
    -FAN   Control  OFF  OFF  OFF  HEATER
     OFF  ON  OFF  OFF  Time Limit   50
     min.  
    a. 80 min. 
    b. 30 min. 
     (
    in case of  D1-E rror )   7
     min.   5 min.    
    C-fan and comp. 
    are linked.    
     
     2.  Initial Defrosting   
    If 
     D
    -s
    ensor < 3.5C, defrosting mode starts from Pre-Cool at initial power input or 
     first plugin.
        
     
     
     
     
     
     
      Pre - Cool  
    Heater
     
    Defrosting   Pause
      Fan Delay  
     
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 27 -
    =
    =
    =
     
    						
    							 
     
    Error Display (LCD Display of F-PCB) 
     
     
     
     
     
     
     
      INPUT
      Control Object
      1.
     Temperature Control Buttons  CUSTOM LCD  CONTEN
    TS  REMARKS  
     
    1. 
    How  to start  
    1)  Set   “LOCK ON ” first.  
    2) Push  “LOCK ” button 3 times while pushing  “REF SET. ” button  at the same time . 
     
    2.  Display   
    E rror code is displayed on Freezer temperature display part.  
     
    3.  How to stop  
    1)  Push  “LOCK ” button 3 times w hile pushing “REF SET. ” button . 
    2)  It stops automatically 4 minutes after the start.  
     
    4.  All the error Ccdes are reset if they turn to be normal.  
       
    5. Error Code  
       
     ERROR CODE
      CONTENTS
      F1
      F-sensor  ; disconnection, short(pull -down)   r1
      R-sensor  ; disconnection, short(pull -down)    rt
      RT-sensor  ; disconnection, short(pull -down)   d1
      D-sensor  ;  disconnection, short(pull -down)   dr
      R-Door  Switch ; defective   dF
      F-Door  Switch ; defective   dH
      Homebar (Refreshment Center)  Door Switch ; defecti ve  C1
      Cycle ; abnormal or defective.   F3
      Return after defrosting ; abnormal or defective  d2
      Forced defrosting mode for A/S    
     
     
     
     
     
     
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 28 -
     
    						
    							 
    CONTENTS
      REMARKS
       
    6. 
     Control  Way of Errors (if any)  
     
     1) F1 ERROR      a. Cause : F-sensor disconnection / short (pull-down) 
       b. Control : Comp. / F-fan -> ON for 25min., OFF for 25min.           
       c. if F-sensor is normal, the error is terminated automatically. 
      
     2) r1 ERROR
     
       a. Cause : R-sensor disconnection / short (pull-down) 
       b. Control  : Condition of ambient temperature 
     RT/S
     
     I
    n  ERROR Work rate 
    ON/OFF  
    8 / 12 
    7 / 13  8 / 12  8 / 12 9 / 11 
       c. If R-sensor is normal, the error is terminated automatically. 
      
     
    3) rt ERROR  
       a. Cause : RT-sensor disconnection / short (pull-down) 
       b. Control : Normal operation, deletion of control condition by RT-sensor 
       c. If RT-sensor is normal, the error is terminated automatically. 
      
     
    4) d1 ERROR  
       a. Cause : D-sensor disconnection / short (pull-down)  
       b. Control : Time limit (30min.) of defrosting-return 
       c. If D-sensor is normal, the error is terminated automatically. 
      
     
    5) D oor ERROR(dF,dR,dH  on display)  
       a. Cause : in case it senses that door is open for more than 1  
      b. Control  : Deletion of function related door switch sensing 
       c. If door switch (open & close) is sensed, the error is terminated autom\
    atically. 
       d. After displaying on LCD the mode is terminated. 
      
     
    6) C1 ERROR  
      a. Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5C 
       b. Control : Normal operation 
       c. When D-sensor temp. is below -5C in comp. OFF, it is terminated. 
      
     
    7) F3 ERROR  
       a. Cause : in case defrosting-return is done by time limit of 80min. 
       b. Control : Deletion of Pre-cool mode in defrosting mode 
       c. If defrosting-return is done by D-sensor, it is terminated. 
      
    8) d2 MODE 
    (A/S  forced defrosting mode)  
      a. Set “LOCK ON” first, then push “REF SET.”  button 5 times while pushing “FRZ SET.” 
     button
     simultaneously . 
      b.  Control : A/S forced defrosting control (Pre-cool is deleted.) 
      c. If D-sensor temp. is over 10C, the mode is terminated  automatically. 
      
     
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 29 -
    ~ 13C          14 ~ 19C          20 ~ 29C          29C ~ 
     
    						
    							 
    Forced Defrosting INPUT
      Control Object
      1.
     “ FRZ SET. ” button  
    2.  “ REF SET. ” button  
    3.  “ LOCK ” button   Defrosting Mode
      CONTENTS
      REMARKS
      1. 
     How to start  
    -> Set “LOCK ON” first, then push “REF SET.”  button 5 times while 
     pushing 
    “FRZ SET. ” button  simultaneously . 
     
    2.   How to proceed  
       1) Delete  Pre -cool mode. (Others are same as normal defrosting.)  
       2) Heater is ON regardless of D -sensor temp. at first 30 seconds.  
          (  Check of defrosting current)     
    6
    -11 . Initial Defrosting   INPUT
      Control Object
      D
    -sensor  
    Initial or first power input (power plugin)  Defrosting Mode
      CONTENTS
      REMARKS
     
    If 
     D
    -sensor temp.
     < 3.5C, defrosting mode starts from Pre-cool at first 
     power input.
      Comp. is delayed for 6 min. 
    at the init ial defrosting.    
    6
    -12. B uzzer or Alarm   INPUT
      Control Object
      F
    -PCB  buttons  
    Door Switch  
    Initial Power Input   BUZZER
      CONTENTS
      REMARKS
      1. 
     Buzzer sounds if any button of  F-PCB  is pushed.  
    2.   Buzzer sounds 3 times 3 minutes after initial power input.  
    3.   Buz zer sounds for 1 second in case of  A/S forced defrosting, short (pull -
    down) operation, explanation mode.   
    4 .   If door is open, buzzer sounds  continually 3 times for 5 seconds.  
        (Door open alarm)    
     
    LCD Background Light INPUT
      Control Object
      F
    -PCB  buttons 
    Door Switch  
    Initial Power Input   LCD BACK LIGHT
      
       
     
     
       
     
     
     
     
     
     
     
     
     
     
    - 30 -
    =
     
    						