Daewoo Frs 2021 Service Manual
Have a look at the manual Daewoo Frs 2021 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 51 Daewoo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SILENT (Silence Mode) INPUT Control Object 1. CDS SENSOR 5. COMP 6. R -FAN 7. F -FAN 8. CUSTOM -LCD CONTENTS REMARKS 1. Purpose of Silence mode To reduce refrigerator noise at night by decresing fan RPM to a minimum d\ egree 2. Condition to start 1) The optical o r light sensor in top middle of control panel senses surround light and \ Silence mode starts if the amount of light sensed is below the standard \ value for more than 1 minute. ( The mode does not start for initial 240 minutes to prevent down of cooli\ ng perfor mance.) a. Standard value to decide ‘night’ : below 5~ 7 Lux (optical sensor surface) b. Standard value to decide ‘daytime’ : above 4~16 Lux (optical sensor surface) 3. Control Method Control Mode F-FAN R-FAN C-FAN Normal 10V 10V 10V Silence Load Control 12V 12V 10V 4. Termination Condition The mode stops if lux value is above the standard for more than 1 minute\ . Control of Each Mode INPUT Control Object 1. CDS SENSOR 2. R SENSOR 3. F SENSOR 1. F -FAN (14V, 12V, 10V) CONTENTS REMARKS * Control of Silence mode : operation mode when the optical sensor feels that it is night * Normal control : daytime operation mode (Refrigerator noise is relatively low at daytime.) * Load control : operation mode when inside temperature goes up due to an increase of load ( foods ) or frequent door openings - 21 -
CO NTE N TS R EM ARKS 1. F an volt a g e o f e ach c o ntr o l m ode 2. C ontr o l a gain st ( u nder) lo ad ( L oad C ontr o l) 1 ) P urp o se : To re sto re F /R-te m pera tu re w hic h h a s ris e n b y lo a d (m uch fo od s in o r fr e qu en t d oo r o pen in gs) a s s o o n a s p ossib le 2 ) Dis p la y : S PEED lig hts u ntil t h e m ode a nd s p eed ic o n s flic ker. 3 ) C ondit io ns to s ta rt ( fr o m b oth N orm al a nd S ile nce) a . F o r R d o or o p en tim e e xce ed s 3 0 s e co n ds a t a tim e - > F re e ze r a nd R efr e ge ra to r lo ad c o ntr o l s ta rts r e sp ectiv e ly . b . O ve r [F-s e nso r O n P oin t + 5b . d eg re e] - > F lo a d c o ntr o l c. O ve r [R-s e nso r O n P oin t + 5 d egre e] - > R lo ad c o n tr o l 4 ) C ond it io n s t o a vo id lo ad c o ntr o l a . In it ia l o pera tio n ( ru ght a fte r p ow er in put) o f r e fr ig era to r b . Ju st a ft e r P re-co ol, He ate r d efr o sting, P ause , D efr o stin g c ycle 5 ) C ontr o l M eth od 5-1 ) C ontr o l m ode b y F /R-d oor o pen t im e (o ve r 3 0 s e co nd s) -> F /R-fa n w ork s b y 1 4 V r e sp ectiv e ly. 5-2 ) C ontr o l m od e b y [F-se n so r O n P oin t + 5 d egre e ] -> F-fa n w ork s b y 1 4V. 5-3) C ontr o l m od e b y [R-se n so r O n P oin t + 5 d egre e] -> R-fa n w ork s b y 14V. * C-fa n w ork s b y 10V a s n o rm al. 6 ) C on dit io ns to sto p a. T he m ode w ork s fo r 2 0 m in ute s. (If a noth er c o ndit io n h appens a t th e e nd o f th e m ode, it s ta rts a gain .) b . W hen it r e ach es to [F-senso r O ff p oin t], F-fa n lo ad c o n tr o l m ode s to ps. c . W hen it r e ach es to [R-se nso r O ff p oin t], R-fa n lo ad c o ntr o l m ode s to ps. C ontr o l M od e F-F A N R-FA N C-FA N N orm al 12 V 12V N orm al 14 V 14V Loa d C on tr o l S ile n ce 1 2 V 12V S ile n ce N orm al 10 V 10V N orm al 10 V 10V S le e p M od e2 L o ad c o ntr o l 12 V 12V 10V - 22 -
CONTENTS REMARKS 3. Control Time Chart of Each Mode 1) Start & stop of load control mode (Normal Control) Door F/S F Fan R/S R Fan Door Open 30 sec. after Open Load Mode Start Frz. Load Stop Rez. Load Stop On + 5deg On + 5deg Frz. Overload Input Frz. Start Condition Frz. Stop ; after 20min. 20min. 20min. Ref. Load14V 14V 12V 12V 2) Start & stop of load control mode (Silence Control) Door F/S F Fan R/S R Fan Door Open 30sec. after openLoad Mode StartRef. Load StopFrz. Load Stop On + 5deg On + 5deg Frz. Overload InputFrz. Load Start Frz. Stop Condition ; after 20min.20min. 20min. Ref. Load 12V 12V 10V 8V 3) Start & stop of load control mode (Normal defrosting control) F/S F Fan R/S R Fan Defrosting StartCondition to start Load Mode, but avoided buring defrosting modeRef. Load Stop On + 5deg Normal Operation 20min. Ref. Load Mode 14V 12V 8V HTR Comp - 23 -
CONTENTS REMARKS 4. Flow Chart of Load Control Mode Sart F/R door open time is over 30 sec. ? F/S ON + 5deg? R-sensor ON + 5deg?Fan RPM F Fan : 12V R Fan : 12V C Fan : 10V Fan RPM Normal Overload F Fan : 10V 12V R Fan : 10V 12V C Fan : 10V 12V Overload of both compartments Y N Freezer Compartment Overload Refrigerator Compartment Overload Y N Y N F load control ; over 20 min. ? F-sensor OFF point ?Overload mode control Overload mode ? Normal mode control N F load control mode stop R-sensor OFF point ? R load control mode stop EndLoad control is avoided ? N Y R load control ; over 20 min. ? Y Y YN Y N N Y NControl Mode Normal 240 minutes ?N Silence - 24 -
Defrosting Cycle INPUT Control Object 1. Total comp. work time 2. Comp. work rate 3. RT temperature 4. Total door open time 1. Defrosting Mode CONTENTS REMARKS 1. Conditions to start defrosting cycle 1) Total comp. work time : 6, 8, 10 hours 2) C omp. work rate (by the 2 hours ) : over 65% 3) Total door open time : 3 minutes (Any door - F or R – open time is over 3 minutes.) 4) Total time of [comp. ON + comp. OFF] : 60 hours 5) Ambient temperature : over 3 5C 6) Any error mode : R1, F1, D1, F3, RT/S, Door -switch 2. Conditions to start defrosting mode 1) The mode starts in the following conditions ; a. Any error happens when total comp. work time is 6 or 8 or 10 hours. b. Comp. work rate by the 2 hours is over 65%. c. Total door open time is over 3 minutes. (Any door - F or R – open time is over 3 minutes.) d. Ambient temperature is over 35C 2) Defrosting mode starts unconditionally as long as total comp. work time\ is 10 hours, even if the above conditions (a~d ) are not satisfied. 3) Defrosting mode starts immediately as long as total time of [comp. ON + \ comp. OFF] is over 60 hours, even if the above 1) and 2) conditions are not satisfie\ d. - 25 -
CONTENTS REMARKS 3. Flow Chart of Defrosting Start Start Ambient temp. is over 35C ?Comp. work time is over 10 hours ? Total time is over 60 hours ? Comp. work time is over 6 hours ? Any error ?Comp. work rate is over 65 % ? EndDefrosting mode starts. Yes Yes Yes Yes Yes Yes No No No No NoNo Comp. work time is over 2 hours ? Total door open time is over 3 minutes ? YesYes No NoComp. work time is over 8 hours ? No No - 26 -
Defrosting Mode INPUT Control Object 1. Defrosting Cycle 1. COMP 2. F -FAN 3. R -FAN 4. HEATER CONTENTS REMARKS 1. Defrosting Mode 1) Time ; 50 minutes 2) C omp. / F-fan : ON R -fan : Control H eater : OFF 3) If F - senso r < - 27C, PRE-COOL becomes OFF. 1) If D- sensor > 10C, Heater becomes OFF. 2) In case of Heater return by time limit of 40 or 80 min (F3 -E rror ) 3) Heater is ON for 30 minutes (time limit) in case of D- sensor error. 4) Time limit a. 30 seconds : Heater is ON regardless of D-sensor temperature right after defrosting start. b. 30 minutes : in case of D1-Error c. 80 minutes : in normal control state 1) Time : 7 minutes C omp., F-fan, R-fan , Heater : OFF 1) Time : 5 minutes C omp. : ON F/R -fan, Heater : OFF * Output control and time limit of each defrosting mode PRE -COOL H eater Defrosting Pause F an Delay COMP ON OFF OFF ON F -FAN ON OFF OFF OFF R -FAN Control OFF OFF OFF HEATER OFF ON OFF OFF Time Limit 50 min. a. 80 min. b. 30 min. ( in case of D1-E rror ) 7 min. 5 min. C-fan and comp. are linked. 2. Initial Defrosting If D -s ensor < 3.5C, defrosting mode starts from Pre-Cool at initial power input or first plugin. Pre - Cool Heater Defrosting Pause Fan Delay - 27 - = = =
Error Display (LCD Display of F-PCB) INPUT Control Object 1. Temperature Control Buttons CUSTOM LCD CONTEN TS REMARKS 1. How to start 1) Set “LOCK ON ” first. 2) Push “LOCK ” button 3 times while pushing “REF SET. ” button at the same time . 2. Display E rror code is displayed on Freezer temperature display part. 3. How to stop 1) Push “LOCK ” button 3 times w hile pushing “REF SET. ” button . 2) It stops automatically 4 minutes after the start. 4. All the error Ccdes are reset if they turn to be normal. 5. Error Code ERROR CODE CONTENTS F1 F-sensor ; disconnection, short(pull -down) r1 R-sensor ; disconnection, short(pull -down) rt RT-sensor ; disconnection, short(pull -down) d1 D-sensor ; disconnection, short(pull -down) dr R-Door Switch ; defective dF F-Door Switch ; defective dH Homebar (Refreshment Center) Door Switch ; defecti ve C1 Cycle ; abnormal or defective. F3 Return after defrosting ; abnormal or defective d2 Forced defrosting mode for A/S - 28 -
CONTENTS REMARKS 6. Control Way of Errors (if any) 1) F1 ERROR a. Cause : F-sensor disconnection / short (pull-down) b. Control : Comp. / F-fan -> ON for 25min., OFF for 25min. c. if F-sensor is normal, the error is terminated automatically. 2) r1 ERROR a. Cause : R-sensor disconnection / short (pull-down) b. Control : Condition of ambient temperature RT/S I n ERROR Work rate ON/OFF 8 / 12 7 / 13 8 / 12 8 / 12 9 / 11 c. If R-sensor is normal, the error is terminated automatically. 3) rt ERROR a. Cause : RT-sensor disconnection / short (pull-down) b. Control : Normal operation, deletion of control condition by RT-sensor c. If RT-sensor is normal, the error is terminated automatically. 4) d1 ERROR a. Cause : D-sensor disconnection / short (pull-down) b. Control : Time limit (30min.) of defrosting-return c. If D-sensor is normal, the error is terminated automatically. 5) D oor ERROR(dF,dR,dH on display) a. Cause : in case it senses that door is open for more than 1 b. Control : Deletion of function related door switch sensing c. If door switch (open & close) is sensed, the error is terminated autom\ atically. d. After displaying on LCD the mode is terminated. 6) C1 ERROR a. Cause : in case comp. works for over 3 hours when D-sensor temp. is over -5C b. Control : Normal operation c. When D-sensor temp. is below -5C in comp. OFF, it is terminated. 7) F3 ERROR a. Cause : in case defrosting-return is done by time limit of 80min. b. Control : Deletion of Pre-cool mode in defrosting mode c. If defrosting-return is done by D-sensor, it is terminated. 8) d2 MODE (A/S forced defrosting mode) a. Set “LOCK ON” first, then push “REF SET.” button 5 times while pushing “FRZ SET.” button simultaneously . b. Control : A/S forced defrosting control (Pre-cool is deleted.) c. If D-sensor temp. is over 10C, the mode is terminated automatically. - 29 - ~ 13C 14 ~ 19C 20 ~ 29C 29C ~
Forced Defrosting INPUT Control Object 1. “ FRZ SET. ” button 2. “ REF SET. ” button 3. “ LOCK ” button Defrosting Mode CONTENTS REMARKS 1. How to start -> Set “LOCK ON” first, then push “REF SET.” button 5 times while pushing “FRZ SET. ” button simultaneously . 2. How to proceed 1) Delete Pre -cool mode. (Others are same as normal defrosting.) 2) Heater is ON regardless of D -sensor temp. at first 30 seconds. ( Check of defrosting current) 6 -11 . Initial Defrosting INPUT Control Object D -sensor Initial or first power input (power plugin) Defrosting Mode CONTENTS REMARKS If D -sensor temp. < 3.5C, defrosting mode starts from Pre-cool at first power input. Comp. is delayed for 6 min. at the init ial defrosting. 6 -12. B uzzer or Alarm INPUT Control Object F -PCB buttons Door Switch Initial Power Input BUZZER CONTENTS REMARKS 1. Buzzer sounds if any button of F-PCB is pushed. 2. Buzzer sounds 3 times 3 minutes after initial power input. 3. Buz zer sounds for 1 second in case of A/S forced defrosting, short (pull - down) operation, explanation mode. 4 . If door is open, buzzer sounds continually 3 times for 5 seconds. (Door open alarm) LCD Background Light INPUT Control Object F -PCB buttons Door Switch Initial Power Input LCD BACK LIGHT - 30 - =