Daewoo Frs 2011i Service Manual
Here you can view all the pages of manual Daewoo Frs 2011i Service Manual. The Daewoo manuals for Fridge freezer are available online for free. You can easily download all the documents as PDF.
Page 41
40 OPERATION AND FUCTIONS MICOM Circuit Power Circuit DC Output Power (Voltage) Point Oscilloscope Measurement Remarks * DC output 15.7V 11.96V
Page 42
41 OPERATION AND FUCTIONS SMPS Movement Wave Drain to Source Break Voltage Point Oscilloscope Measurement Remarks SMP SIC PIN 1,2 *Voltage between DRAIN and SOURCE : below 650V OVP(Overvoltage Protection) Wave at power input Point Oscilloscope Measurement Remarks SMPS IC PIN 3,4 *Minimum standard voltage OVP start : 23.2V at
Page 43
42 OPERATION AND FUCTIONS Initial Power Wave of Switching Power IC Point Oscilloscope Measurement Remark SMPS IC PIN 3,4
Page 44
43 OPERATION AND FUCTIONS Sensors Circuit Diagram Fnction of Each Sensor [ F-sensor ] 1) It senses the temperature of freezer compartment and controls Comp., F-fan ON / OFF. 2) How it works ; Working Point Low ON Mid OFF High OFF Working Temp. -11.0 -20.0 - 26.0 Resistance 14.74k 22.33k 30.92k Sensing Voltage 3.50 V 3.00 V 2.14 V [ D-sensor ] It senses return point of defrosting heater. Working Point Return point of defrosting heater Working Temp. 10...
Page 45
44 OPERATION AND FUCTIONS 1) Cut J18 on M-PCB, then temp. is low e red -2 than [Mid OFF point]. 2) In addition to 1) action, cut J22 on M-PCB, then the temp. is low e red -1 more. Relay Function Circuit Diagram How it works ; ON Conditi on OFF Condition C ontrol Control Method MI CO M POR T IC 2 Output PIN MICOM POR T IC 03 Out put PIN COMP REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY #1 3.7V #10 0.7V #1 0V #10 12V R-LAMP #4...
Page 46
45 OPERATION AND FUCTIONS Fan Function How it works ; ON Condition OFF Condition MICOM Port MICOM Port Control Object Control Method 31 32 33 IC Collector 31 32 33 IC Collector Low (10V) operation 5V 0V 0V 10.35V 0V Mid (12V) operation 0V 5V 0V 12.19V 0V F-FAN High (14V) operation 0V 0V 0V 14.38V 5V 5V 5V 0V ON Condition OFF Condition MICOM PORT MICOM Port Control Object Control Method 39 40 41 IC Collector 39 40 41 IC Collector Low (10V) operation 0V 5V 5V 10.38V 0V...