Daewoo Fr 291 Service Manual
Have a look at the manual Daewoo Fr 291 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 51 Daewoo manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2 1. SPECIFICATION 1. MAJOR ACCESSORIES NAME Q’TY ICING CASE 1 FREEZER SHELF 1 FREEZER ROOM FREEZER POCKET 2 REF. SHELF 2 COVER VEGETB CASE 1 VEGETABLE CASE 1 EGG CASE 1 EGG POCKET 1 UTILITY POCKET 1 JUMBO POCKET 1 REFRIGERATOR ROOM BOTTLE POCKET 1 2. QUALITY SPECIFICATION CLASIFICATION CONTENTS FR-291 FREEZER 73L REFRIGERATOR 173L GROSS TOTAL 246L FREEZER 62L REFRIGERATOR 159L CAPACITY (L) STORAGE TOTAL 221L WIDTH 545 DEPTH 584 EXTERNAL DIMENSION HEIGHT 1620 DEFROST SYSTEM FORCED DEFROST CONTROL AUTOMATIC START & STOP COMPRESSOR YX58LHP5 REFRIGERANT(g) R-134a, 75 g COOLING & CONTROL SYSTEM REFRIGERATOR DEGREE INPUT VOLTAGE 220~240V COMPRESSOR 0.6A HEATER 190W ELECTRIC CHARACTER ELECTRIC CONSUMPTION 390 KWh/Year WEIGHT 53 Kg
7 6. WIRE DIAGRAM & SOLID WIRE DIAGRAM 1) WIRE DIAGRAM
9 7. MAIN COMPONENTS 1. COMPRESSOR FR – 291 MODEL YX58LHP5 STARTING TYPE RSCR VOLTAGE 230V / 50Hz MAIN COIL RESISTANCE 19.4 Ω SUB COIL RESISTANCE 25.6 Ω 2. RELAY FR – 291 MODEL 4TM129SHBYY-52 RESISTANCE 33 Ω MAX. VOLTAGE 355V PTC MAX. CURRENT 6A OL CURRENT 3.5A 3. RUNNING CAPACITOR FR – 291 VOLTAGE AC 400V RATED CAPACITY 4㎌ 4. LAMP FR – 291 VOLTAGE AC 240V / 15W
10 5. POWER CORD FR – 291 TYPE 3x0.75 ㎟ LENGTH 1.80m 6. TEMPERATURE FUSE FR – 291 VOLTAGE 250V CURRENT 10A WORKING TEMP. 77 ℃ 7. Bi-METAL FR – 291 MODEL PST - 3 OFF TEMP. 12 ± 3 7. DEFROST TIMER FR – 291 MOEDL CF-3001-21 CYCLE TIME 12 HR ± 10.8 MIN 8. DEFROST HEATER FR – 291 RATING AC 230V / 190W RESISTANCE 269 Ω